The New Method in Calculating Columns and Beams Dimensions That Meets Requirements of The Strong Column-Weak Beam and Non-Soft Story

Livian Teddy, G. Hardiman, N. Nuroji, S. Tudjono
{"title":"The New Method in Calculating Columns and Beams Dimensions That Meets Requirements of The Strong Column-Weak Beam and Non-Soft Story","authors":"Livian Teddy, G. Hardiman, N. Nuroji, S. Tudjono","doi":"10.14710/JADU.V1I2.4492","DOIUrl":null,"url":null,"abstract":"Situated at an earthquake prone area, buildings planning in Indonesia must implement earthquake resistant building principles. One of these principles is determining dimensions of columns and beams in the process of architectural designing.This act eventually affects the behaviour of the strong column-weak beam and the probability of bending failure due to soft story. At present time, there are no simple rules architects can use in calculating the dimensions of beams and columns that meet the criteria for strong column-weak beam and non-soft story. This paper is an effort to provide an input to the architects in designing the dimensions of the columns and beams. This research is a review result of three theories namely: 1). The theory of columns and beams preliminary design, 2). The theory of the strong column-weak beam concept, and 3). The theory of soft story and column slenderness. Those theories were then synthesized into a spreadsheet. To meet the criteria for strong column-weak beam and non-soft story, the following procedures must be done : 1). Determine the columns’ dimensions according to 0.15% of the columns’ cumulative tributary area, 2). Determine the beams’ dimensions according to 1/12 of the beams’ span and the beams’ plastic modulus, 3). Determine the columns’ dimensions and the columns’plastic modulus, 4). Determine the columns’ height based on the column slenderness criteria, and 5). Compare the columns plastic modulus and the beams plastic modulus and check whether they meet the criteria “the columns’plastic modulus ≥ 1.2 * the beams’ plastic modulus”.","PeriodicalId":153057,"journal":{"name":"Journal of Architectural Design and Urbanism","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Architectural Design and Urbanism","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14710/JADU.V1I2.4492","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Situated at an earthquake prone area, buildings planning in Indonesia must implement earthquake resistant building principles. One of these principles is determining dimensions of columns and beams in the process of architectural designing.This act eventually affects the behaviour of the strong column-weak beam and the probability of bending failure due to soft story. At present time, there are no simple rules architects can use in calculating the dimensions of beams and columns that meet the criteria for strong column-weak beam and non-soft story. This paper is an effort to provide an input to the architects in designing the dimensions of the columns and beams. This research is a review result of three theories namely: 1). The theory of columns and beams preliminary design, 2). The theory of the strong column-weak beam concept, and 3). The theory of soft story and column slenderness. Those theories were then synthesized into a spreadsheet. To meet the criteria for strong column-weak beam and non-soft story, the following procedures must be done : 1). Determine the columns’ dimensions according to 0.15% of the columns’ cumulative tributary area, 2). Determine the beams’ dimensions according to 1/12 of the beams’ span and the beams’ plastic modulus, 3). Determine the columns’ dimensions and the columns’plastic modulus, 4). Determine the columns’ height based on the column slenderness criteria, and 5). Compare the columns plastic modulus and the beams plastic modulus and check whether they meet the criteria “the columns’plastic modulus ≥ 1.2 * the beams’ plastic modulus”.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
强柱弱梁和非软层结构柱、梁尺寸计算新方法
印度尼西亚位于地震易发地区,建筑规划必须实施抗震建筑原则。其中一个原则是在建筑设计过程中确定柱和梁的尺寸。这种作用最终影响到强柱弱梁的性能和软层弯曲破坏的概率。目前,对于满足强柱-弱梁和非软层标准的梁柱尺寸计算,还没有简单的规则可供建筑师使用。本文旨在为建筑师在设计柱和梁的尺寸时提供参考。本研究是对梁柱初步设计理论、强柱弱梁概念理论、软层和柱长细比理论三种理论的回顾。这些理论随后被合成到一个电子表格中。为了满足强柱弱梁和非软层的标准,必须完成以下程序:1).按柱累计支路面积的0.15%确定柱的尺寸,2).按梁跨度的1/12和梁的塑性模量确定梁的尺寸,3).按柱的尺寸和塑性模量确定柱的高度,4).按柱的长细标准确定柱的高度,5)比较柱的塑性模量和梁的塑性模量,检查是否符合“柱的塑性模量≥1.2 *梁的塑性模量”的标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Mitigating Climate Change Towards Livable City (Case: Bandung City, West Java) Effect of Population Density and Urban Intensity on Building Typology in South Krembangan Area Exploring Experience and First Impression in The Liminal Spaces (Case Studies: Corridors and Stairs in Campus Environment) Temporary Space: A Reflection upon ‘Good City Form’ Material-Based Learning in Architecture Design Studio: From ‘Beaux-Arts’ to ‘Bauhaus’ into Current Educational Era
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1