Output Voltage Control of A Four-Leg Inverter Based Three-Phase UPS by Means of Stationary Frame Resonant Filter Banks

E. Demirkutlu, S. Çetinkaya, A. Hava
{"title":"Output Voltage Control of A Four-Leg Inverter Based Three-Phase UPS by Means of Stationary Frame Resonant Filter Banks","authors":"E. Demirkutlu, S. Çetinkaya, A. Hava","doi":"10.1109/IEMDC.2007.382785","DOIUrl":null,"url":null,"abstract":"A method for high performance output voltage control of a four-leg inverter (FLI) based three-phase UPS is proposed. Stationary frame resonant filter bank based output voltage control loop, which is complemented by capacitor current feedback based active damping loop, is employed. Utilizing the zero-state partitioning variable, a generalized form of scalar PWM for the FLI is developed and the minimum loss discontinuous PWM method is derived. The controller and modulator design and implementation details for the FLI-UPS are given. Linear and nonlinear loads for balanced and unbalanced load operating conditions are considered. The scalar control and PWM methods are proven by means of theory, simulations, and experiments.","PeriodicalId":446844,"journal":{"name":"2007 IEEE International Electric Machines & Drives Conference","volume":"73 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"33","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE International Electric Machines & Drives Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMDC.2007.382785","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 33

Abstract

A method for high performance output voltage control of a four-leg inverter (FLI) based three-phase UPS is proposed. Stationary frame resonant filter bank based output voltage control loop, which is complemented by capacitor current feedback based active damping loop, is employed. Utilizing the zero-state partitioning variable, a generalized form of scalar PWM for the FLI is developed and the minimum loss discontinuous PWM method is derived. The controller and modulator design and implementation details for the FLI-UPS are given. Linear and nonlinear loads for balanced and unbalanced load operating conditions are considered. The scalar control and PWM methods are proven by means of theory, simulations, and experiments.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于固定框架谐振滤波器组的四腿逆变器三相UPS输出电压控制
提出了一种基于四脚逆变器(FLI)的三相UPS的高性能输出电压控制方法。采用基于固定框架谐振滤波器组的输出电压控制回路,辅以基于电容电流反馈的主动阻尼回路。利用零状态划分变量,提出了FLI的标量PWM的广义形式,并推导了最小损耗间断PWM方法。给出了控制器和调制器的设计和实现细节。考虑了平衡和不平衡负载工况下的线性和非线性负载。通过理论、仿真和实验验证了标量控制和PWM控制方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Output Voltage Control of A Four-Leg Inverter Based Three-Phase UPS by Means of Stationary Frame Resonant Filter Banks Performance Assessment of a PM Wind Generator with Machined SMC Cores Detection of Broken Rotor Bar Faults and Effects of Loading in Induction Motors during Rundown Analysis of Electrical Loss in Single Phase Induction Motors A Space Vector Strategy for Smooth Torque Control of Switched Reluctance Machines
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1