{"title":"Application of a new radiation thermometry method to galvannealed and cold-rolled steels","authors":"F. Tanaka, H. Ohira, Y. Naganuma","doi":"10.1109/IMTC.1989.36814","DOIUrl":null,"url":null,"abstract":"The authors describe an experimental and analytical study of a novel radiation thermometry method. The method uses a priori knowledge concerning the reciprocal relationship between two uniquely defined spectral emissivities, making quite accurate temperature measurement possible for materials to which conventional spectral and ratio methods are not applicable. The validity of the method is demonstrated by experimental results on galvannealed and cold-rolled steel specimens, whose emissivity changes by alloying and oxidation, respectively. Zinc film thickness, steel grade, and alloying temperature had little effect on the reciprocity function for the two emissivities. It is concluded that the use of two polarized spectral emissivities at the same wavelength can be advantageous in measuring the temperature and emissivities of cold-rolled steel in a continuous annealing furnace.<<ETX>>","PeriodicalId":298343,"journal":{"name":"6th IEEE Conference Record., Instrumentation and Measurement Technology Conference","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"6th IEEE Conference Record., Instrumentation and Measurement Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.1989.36814","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The authors describe an experimental and analytical study of a novel radiation thermometry method. The method uses a priori knowledge concerning the reciprocal relationship between two uniquely defined spectral emissivities, making quite accurate temperature measurement possible for materials to which conventional spectral and ratio methods are not applicable. The validity of the method is demonstrated by experimental results on galvannealed and cold-rolled steel specimens, whose emissivity changes by alloying and oxidation, respectively. Zinc film thickness, steel grade, and alloying temperature had little effect on the reciprocity function for the two emissivities. It is concluded that the use of two polarized spectral emissivities at the same wavelength can be advantageous in measuring the temperature and emissivities of cold-rolled steel in a continuous annealing furnace.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种新的辐射测温方法在镀锌和冷轧钢中的应用
作者描述了一种新的辐射测温方法的实验和分析研究。该方法利用关于两个唯一定义的光谱发射率之间的互反关系的先验知识,使得对传统光谱和比率方法不适用的材料进行相当精确的温度测量成为可能。通过对镀锌钢和冷轧钢试样的实验结果,验证了该方法的有效性。锌膜厚度、钢种、合金温度对两种发射率的互易函数影响不大。结果表明,在连续退火炉中使用同一波长的两个偏振光谱发射率有利于冷轧钢的温度和发射率的测量
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A high-current, very-wide-band transconductance amplifier New in-situ calibration of diode detectors used in six-port network analyzers An expert ECG acquisition and analysis system Recent developments in digital oscilloscopes Tactile sensing for space robotics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1