Development of Incubator Analyzer Using Personal Computer Equiped With Measurement Certificate

Laily Nurrohmah, D. Andayani, A. Pudji
{"title":"Development of Incubator Analyzer Using Personal Computer Equiped With Measurement Certificate","authors":"Laily Nurrohmah, D. Andayani, A. Pudji","doi":"10.35882/jeeemi.v2i2.6","DOIUrl":null,"url":null,"abstract":"Baby incubators are used for premature babies where babies are born prematurely. To ensure the accuracy of medical devices, periodic tests and controls need to be carried out aimed at reducing the risk of measurement. The baby incubator can be tested with a calibration device which is a device to calibrate temperature, noise, humidity, and airflow so that conditions remain stable and within normal limits. The purpose of this study was the development of a PC (Personal Computer) performing Incubator Analyzer with noise and airflow parameters. This type of research uses after only design. The standard incubator analyzer is not equipped with a PC and data processing via Excel, so the researchers created an Incubator Analyzer device that has four parameters to measure temperature, noise, humidity, and airflow. Using the Atmega328 Microcontroller as a data processor, equipped with sending data via Bluetooth HC-05 with data storage and output results will be displayed on a PC. Noise parameters using the Analog Sound Sensor V2 sensor and have the biggest error at 37oC setting temperature that is equal to 0.17%. While the airflow parameter uses an airflow sensor with type D6F-V3A01 and has the biggest error that is 0.5% at a temperature setting of 36oC and 37oC. The use of displays on personal computers and data processing using Excel, allows users to monitor calibration and data processing. The feasibility of this device is proven. Therefire, this design can be used for baby incubator calibration.","PeriodicalId":369032,"journal":{"name":"Journal of Electronics, Electromedical Engineering, and Medical Informatics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electronics, Electromedical Engineering, and Medical Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35882/jeeemi.v2i2.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Baby incubators are used for premature babies where babies are born prematurely. To ensure the accuracy of medical devices, periodic tests and controls need to be carried out aimed at reducing the risk of measurement. The baby incubator can be tested with a calibration device which is a device to calibrate temperature, noise, humidity, and airflow so that conditions remain stable and within normal limits. The purpose of this study was the development of a PC (Personal Computer) performing Incubator Analyzer with noise and airflow parameters. This type of research uses after only design. The standard incubator analyzer is not equipped with a PC and data processing via Excel, so the researchers created an Incubator Analyzer device that has four parameters to measure temperature, noise, humidity, and airflow. Using the Atmega328 Microcontroller as a data processor, equipped with sending data via Bluetooth HC-05 with data storage and output results will be displayed on a PC. Noise parameters using the Analog Sound Sensor V2 sensor and have the biggest error at 37oC setting temperature that is equal to 0.17%. While the airflow parameter uses an airflow sensor with type D6F-V3A01 and has the biggest error that is 0.5% at a temperature setting of 36oC and 37oC. The use of displays on personal computers and data processing using Excel, allows users to monitor calibration and data processing. The feasibility of this device is proven. Therefire, this design can be used for baby incubator calibration.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
装有测量证书的微机培养箱分析仪的研制
婴儿保温箱用于早产儿,婴儿过早出生。为了确保医疗器械的准确性,需要进行旨在减少测量风险的定期测试和控制。婴儿保温箱可以用校准装置进行测试,校准装置是一种校准温度,噪音,湿度和气流的装置,使条件保持稳定并在正常范围内。本研究的目的是开发一台PC(个人电脑)执行培养箱分析仪的噪音和气流参数。这种类型的研究只采用事后设计。标准的培养箱分析仪没有配备PC机,也没有通过Excel进行数据处理,因此研究人员开发了一种具有温度、噪音、湿度、气流等4个参数的培养箱分析仪。使用Atmega328微控制器作为数据处理器,配备通过蓝牙HC-05发送数据,并将数据存储和输出结果显示在PC上。噪声参数采用Analog Sound Sensor V2传感器,在37℃设定温度下误差最大,为0.17%。而气流参数使用D6F-V3A01型气流传感器,在36℃和37℃的温度设置下误差最大,为0.5%。在个人电脑上使用显示器和Excel进行数据处理,允许用户进行监控校准和数据处理。验证了该装置的可行性。因此,本设计可用于婴儿保温箱的标定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Predicting the Need for Cardiovascular Surgery: A Comparative Study of Machine Learning Models A Comparative Study of Convolutional Neural Network in Detecting Blast Cells for Diagnose Acute Myeloid Leukemia A Comparative Study of Machine Learning Methods for Baby Cry Detection Using MFCC Features Analysis of Multimodal Biosignals during Surprise Conditions Correlates with Psychological Traits Evaluation of two biometric access control systems using the Susceptible-Infected-Recovered model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1