Determination of Pediatric Patient Companion Dose at Thoracic X-Ray Examination

Ega Duandini, E. Hidayanto, W. Budi
{"title":"Determination of Pediatric Patient Companion Dose at Thoracic X-Ray Examination","authors":"Ega Duandini, E. Hidayanto, W. Budi","doi":"10.14710/jpa.v5i1.14011","DOIUrl":null,"url":null,"abstract":"Thorax radiography examination in pediatric patients is one of the most frequent examinations because of many abnormalities that occur in the thorax and have a high probability at children's age. Pediatric patients are assisted by a companion from the adult patient's family. Calculation and measurement of the radiation dose received by the companion are very important as they are in the examination room with the patient during the imaging process. And no matter how small the radiation dose received by the companion, there will be an opportunity for stochastic effect. The Indonesian Nuclear Energy Regulatory Agency regulation Number 4 of the Year 2020 on Radiation Safety in the Use of X-Ray Machines in Diagnostic and Interventional Radiology, regulates the dose received by patient companions must be less than 5 mSv. This study aims to analyze the relationship between the exposure factor and the radiation dose received by the patient's companion. The TLDs used to measure the radiation dose was placed on the companion's chest. The radiation dose was calculated using the Klein-Nishina formula. The results show that the dose received by the companion ranged from 0.39 × 10-5 mSv to 4.64 × 10-5 mSv, which is much lower than the permissible dose.","PeriodicalId":280868,"journal":{"name":"Journal of Physics and Its Applications","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physics and Its Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14710/jpa.v5i1.14011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Thorax radiography examination in pediatric patients is one of the most frequent examinations because of many abnormalities that occur in the thorax and have a high probability at children's age. Pediatric patients are assisted by a companion from the adult patient's family. Calculation and measurement of the radiation dose received by the companion are very important as they are in the examination room with the patient during the imaging process. And no matter how small the radiation dose received by the companion, there will be an opportunity for stochastic effect. The Indonesian Nuclear Energy Regulatory Agency regulation Number 4 of the Year 2020 on Radiation Safety in the Use of X-Ray Machines in Diagnostic and Interventional Radiology, regulates the dose received by patient companions must be less than 5 mSv. This study aims to analyze the relationship between the exposure factor and the radiation dose received by the patient's companion. The TLDs used to measure the radiation dose was placed on the companion's chest. The radiation dose was calculated using the Klein-Nishina formula. The results show that the dose received by the companion ranged from 0.39 × 10-5 mSv to 4.64 × 10-5 mSv, which is much lower than the permissible dose.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
儿科患者胸部x线检查伴随剂量的测定
胸部x线检查是儿科患者最常见的检查之一,因为许多异常发生在胸部,并且在儿童年龄有很高的概率。儿科患者由成人患者家属的一名同伴协助。计算和测量同伴所接受的辐射剂量是非常重要的,因为他们在成像过程中与患者在检查室。无论同伴接受的辐射剂量有多小,都有可能产生随机效应。印度尼西亚核能监管机构关于诊断和介入放射学中使用x射线机的辐射安全的2020年第4号条例规定,患者同伴接受的剂量必须低于5毫西弗。本研究旨在分析照射因子与患者同伴所受辐射剂量的关系。用于测量辐射剂量的tld被放置在同伴的胸部。辐射剂量是用Klein-Nishina公式计算的。结果表明,同伴所受剂量范围为0.39 ~ 4.64 × 10-5 mSv,远低于允许剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of Percentage Depth Doses with the Published Data for Co-60 Radiotherapy Machine at a Regional Cancer Hospital Effectiveness of Noise Barriers Based on Waste Materials in Case Study of Residential Noise Due to Double-Track Railways Development of Sasirangan Liquid Waste Treatment System Using Ozonization Method Using Composite Ceramic Filter Media Based on Water Chestnut (Eleocharis Dulcis) Optical Response of Various Heavy Metal Ions-Based Carbon Dots Photoluminescent Quenching Effect Analysis of Clay Mineral Transformation in Plambik Village, Central Lombok Using X-Ray Diffraction and Scanning Electron Microscope Methods
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1