Two Phase Heat Transfer Coefficient for Minichannel Condensers

IRPN: Science Pub Date : 2017-12-21 DOI:10.2139/ssrn.3101285
V. Bhatkar, V. Kriplani, G. Awari
{"title":"Two Phase Heat Transfer Coefficient for Minichannel Condensers","authors":"V. Bhatkar, V. Kriplani, G. Awari","doi":"10.2139/ssrn.3101285","DOIUrl":null,"url":null,"abstract":"Vapour compression refrigeration (VCR) system was designed, developed and fabricated for testing alternative refrigerants such as R152a, R600a, R290 and mixture of R290/R600a (50/50 by wt %) over presently used R134a with aluminium minichannel condenser. In the test set up, heater bank was provided for controlling condensation temperature and evaporator temperature along with sub-cooling and superheating temperature by using PID controllers. All the refrigerants were tested for condensation temperature ranging from 40 to 55 °C while evaporation temperature ranges from -15 to 15 °C. Refrigerant charge was reduced drastically with the minichannel condenser over the conventional condenser. Two phase condensation heat transfer coefficient correlation was developed from the experimental data points to design minichannel and conventional condenser and found in good agreement with the existing well known correlations.","PeriodicalId":198407,"journal":{"name":"IRPN: Science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IRPN: Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2139/ssrn.3101285","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Vapour compression refrigeration (VCR) system was designed, developed and fabricated for testing alternative refrigerants such as R152a, R600a, R290 and mixture of R290/R600a (50/50 by wt %) over presently used R134a with aluminium minichannel condenser. In the test set up, heater bank was provided for controlling condensation temperature and evaporator temperature along with sub-cooling and superheating temperature by using PID controllers. All the refrigerants were tested for condensation temperature ranging from 40 to 55 °C while evaporation temperature ranges from -15 to 15 °C. Refrigerant charge was reduced drastically with the minichannel condenser over the conventional condenser. Two phase condensation heat transfer coefficient correlation was developed from the experimental data points to design minichannel and conventional condenser and found in good agreement with the existing well known correlations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
小通道冷凝器的两相传热系数
蒸汽压缩制冷(VCR)系统的设计,开发和制造用于测试替代制冷剂,如R152a, R600a, R290和R290/R600a的混合物(50/50 wt %)超过目前使用的R134a与铝制小通道冷凝器。在试验装置中,加热器组通过PID控制器控制冷凝温度和蒸发器温度以及过冷和过热温度。所有制冷剂的冷凝温度范围为40至55℃,蒸发温度范围为-15至15℃。与传统冷凝器相比,小通道冷凝器大大减少了制冷剂充注量。从实验数据点出发,建立了两相冷凝换热系数的关系式,并与已有的关系式相吻合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Why the COLREGS Will Need to be Amended to Accommodate Unmanned Vessels Industrial Robots and Finance Spread Options: From Margrabe to Kirk Design of 3-Level Inverter Using FIXCOM Impact of Artificial Intelligence in the Field of Education
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1