{"title":"Experimental measurement of structural intensity on an aircraft fuselage","authors":"J. Cuschieri","doi":"10.3397/1.2827798","DOIUrl":null,"url":null,"abstract":"An experimental technique was used to measure structural intensity through an aircraft fuselage with an excitation load applied near one of the wing attachment locations. The fuselage was relatively large, requiring several measurement locations to analyze the intensity flow through the whole of the structure. For the measurement of structural intensity, the use of a transducer array was necessary at every location of interest. A trade-off was therefore required between the number of measurement transducers, the mounting of these transducers, and the accuracy of the measurements. Using four accelerometers mounted on a bakelite platform, structural intensity vectors were measured at locations distributed throughout the fuselage. The results of these measurements, together with a discussion on the suitability of the approach for measuring structural intensity on a real structure, are presented in this paper.","PeriodicalId":179775,"journal":{"name":"New Civil Engineer","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1991-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"New Civil Engineer","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3397/1.2827798","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10
Abstract
An experimental technique was used to measure structural intensity through an aircraft fuselage with an excitation load applied near one of the wing attachment locations. The fuselage was relatively large, requiring several measurement locations to analyze the intensity flow through the whole of the structure. For the measurement of structural intensity, the use of a transducer array was necessary at every location of interest. A trade-off was therefore required between the number of measurement transducers, the mounting of these transducers, and the accuracy of the measurements. Using four accelerometers mounted on a bakelite platform, structural intensity vectors were measured at locations distributed throughout the fuselage. The results of these measurements, together with a discussion on the suitability of the approach for measuring structural intensity on a real structure, are presented in this paper.