Characterization of sampling schemes for whole body PET imaging

M. Dahlbom, P. Cutler, W. Digby, W. K. Luk, J. Reed
{"title":"Characterization of sampling schemes for whole body PET imaging","authors":"M. Dahlbom, P. Cutler, W. Digby, W. K. Luk, J. Reed","doi":"10.1109/NSSMIC.1993.373614","DOIUrl":null,"url":null,"abstract":"Whole body PET images suffers by relatively high noise levels due to inherent poor counting statistics in the emission data. It is therefore important to optimize the acquisition parameters to minimize any additional noise contamination. It has previously been shown that using a continuous or redundant acquisition scheme, improvements in noise characteristics and image quality are seen. In this work the continuous sampling is further characterized and compared to the conventional step and shoot acquisition. The main sources of noise contamination using conventional sampling is due to the normalization procedure which is applied to the emission data. By using continuous sampling and using a common normalization for all planes, the statistical noise in the normalization is improved by factor close to the number of planes in the scanner. The continuous sampling showed to be less sensitive to small patient movements (<5 mm) compared to conventional scanning. Previously reported problems of data handling have been resolved by rewriting the acquisition firmware to allow on-line addition of the redundant sampled data in hardware.<<ETX>>","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"35 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1993.373614","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

Abstract

Whole body PET images suffers by relatively high noise levels due to inherent poor counting statistics in the emission data. It is therefore important to optimize the acquisition parameters to minimize any additional noise contamination. It has previously been shown that using a continuous or redundant acquisition scheme, improvements in noise characteristics and image quality are seen. In this work the continuous sampling is further characterized and compared to the conventional step and shoot acquisition. The main sources of noise contamination using conventional sampling is due to the normalization procedure which is applied to the emission data. By using continuous sampling and using a common normalization for all planes, the statistical noise in the normalization is improved by factor close to the number of planes in the scanner. The continuous sampling showed to be less sensitive to small patient movements (<5 mm) compared to conventional scanning. Previously reported problems of data handling have been resolved by rewriting the acquisition firmware to allow on-line addition of the redundant sampled data in hardware.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
全身PET成像取样方案的特性
由于发射数据中固有的较差的计数统计,全身PET图像遭受相对较高的噪声水平。因此,重要的是优化采集参数,以尽量减少任何额外的噪声污染。以前已经表明,使用连续或冗余采集方案,可以看到噪声特性和图像质量的改善。在这项工作中,进一步表征了连续采样,并与传统的步进采样进行了比较。传统采样的主要噪声源是由于对排放数据进行了归一化处理。通过对所有平面进行连续采样和通用归一化,归一化过程中的统计噪声得到了与扫描仪中平面数相近的系数的改善。连续取样显示对病人的小动作不太敏感(>
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation Of Wavelength Shifters For Spectral Separation Of Barium Fluoride Emissions High-speed Reconstruction Of SPECT Mages With A Tailored Piecewise Neural Network A 12-channel VMEBUS-based Pulse-height Analysis Module A Bipolar Analog Front-end Integrated Circuit For The SDC Silicon Tracker Detection geometry and reconstruction error in magnetic source imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1