J. Probst, H. Löchel, T. Krist, C. Braig, C. Seifert
{"title":"Soft X-ray spectroscopy in the lab with an ellipsoidal mirror and a wavefront corrected reflection zone plate","authors":"J. Probst, H. Löchel, T. Krist, C. Braig, C. Seifert","doi":"10.1117/12.2663780","DOIUrl":null,"url":null,"abstract":"We present first experimental results on wavelength-dispersive soft X-ray spectroscopy of TiO2 in the vicinity of the Ti Lσ fluorescence line with a central energy of about 452.2 eV, demonstrating the functionality of a newly developed, laboratory-scaled setup. In our instrument, the micron-sized photon emission from an electronexcited source is collected efficiently by a rotationally symmetric, ellipsoidal mirror and subsequently dispersed by a reflection zone plate with inscribed diffractive wavefront correction, to compensate for figure and alignment errors of the ellipsoid to some degree. The measured data, recorded with a CCD camera in one meter from the source, show clearly separated peaks from different Ti L (398.3 eV and 452.2 eV) contributions and O Kα emission (523.1 eV) with an energy resolving power around 38 and a signal-to-noise ratio between 4.4 and 10.7.","PeriodicalId":376481,"journal":{"name":"Optics + Optoelectronics","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optics + Optoelectronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2663780","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
We present first experimental results on wavelength-dispersive soft X-ray spectroscopy of TiO2 in the vicinity of the Ti Lσ fluorescence line with a central energy of about 452.2 eV, demonstrating the functionality of a newly developed, laboratory-scaled setup. In our instrument, the micron-sized photon emission from an electronexcited source is collected efficiently by a rotationally symmetric, ellipsoidal mirror and subsequently dispersed by a reflection zone plate with inscribed diffractive wavefront correction, to compensate for figure and alignment errors of the ellipsoid to some degree. The measured data, recorded with a CCD camera in one meter from the source, show clearly separated peaks from different Ti L (398.3 eV and 452.2 eV) contributions and O Kα emission (523.1 eV) with an energy resolving power around 38 and a signal-to-noise ratio between 4.4 and 10.7.