{"title":"Ultra wide-band high-order pulse digital transmitter IC in 90nm CMOS for biomedical radar sensing","authors":"Xubo Wang, A. Dinh, D. Teng","doi":"10.1109/ICUWB.2011.6058858","DOIUrl":null,"url":null,"abstract":"In this paper, an UWB transmitter for next generation bio-radar sensing system characterized by a high data rate, low area, low power consumption, and low complexity, and specifically designed to fit Canada UWB spectrum mask, is proposed for real-time bio-medical sensing. The transmitter is based on an all digitally controlled circuit pulse generator in 90nm CMOS to generate the tenth-order derivative of Gaussian pulse with bi-phase modulation scheme operating in the 6–10GHz band specified by Canada draft spectrum specification. The switch diplexer presents a 0.5dB insertion loss. The transmitter core occupies an chip area of 200um×140um. Simulating on a 1V voltage supply, the transmitter draws average 9.037mW when generating the tenth-order Gaussian derivative pulses at a pulse repetition frequency of 50MHz. The transmitter has an output power of 7.08dBm and each pulse carries an energy of 3.1pJ.The pulse is digitally synthesized and bi-phase modulated. This transmitter prototype can generate any other pulse combinations with minor design modifications. The predicted performance of the bio-radar is also evaluated and discussed.","PeriodicalId":143107,"journal":{"name":"2011 IEEE International Conference on Ultra-Wideband (ICUWB)","volume":"121 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Conference on Ultra-Wideband (ICUWB)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICUWB.2011.6058858","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
In this paper, an UWB transmitter for next generation bio-radar sensing system characterized by a high data rate, low area, low power consumption, and low complexity, and specifically designed to fit Canada UWB spectrum mask, is proposed for real-time bio-medical sensing. The transmitter is based on an all digitally controlled circuit pulse generator in 90nm CMOS to generate the tenth-order derivative of Gaussian pulse with bi-phase modulation scheme operating in the 6–10GHz band specified by Canada draft spectrum specification. The switch diplexer presents a 0.5dB insertion loss. The transmitter core occupies an chip area of 200um×140um. Simulating on a 1V voltage supply, the transmitter draws average 9.037mW when generating the tenth-order Gaussian derivative pulses at a pulse repetition frequency of 50MHz. The transmitter has an output power of 7.08dBm and each pulse carries an energy of 3.1pJ.The pulse is digitally synthesized and bi-phase modulated. This transmitter prototype can generate any other pulse combinations with minor design modifications. The predicted performance of the bio-radar is also evaluated and discussed.