Rapid estimation of serum myoglobin concentration during rhabdomyolysis with a latex-agglutination test (Rapi-Tex).

Acta chirurgica Scandinavica Pub Date : 1990-08-01
T Andersen, P J Jørgensen, E Toft, L K Nielsen, K N Hansen
{"title":"Rapid estimation of serum myoglobin concentration during rhabdomyolysis with a latex-agglutination test (Rapi-Tex).","authors":"T Andersen,&nbsp;P J Jørgensen,&nbsp;E Toft,&nbsp;L K Nielsen,&nbsp;K N Hansen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A latex-agglutination test (Rapi-Tex) was used for semiquantitative estimation of myoglobin concentration in 89 serum samples obtained from ten patients undergoing lower-limb arterial embolectomy. Each serum sample was tested with Rapi-Tex both undiluted and after 1:50 dilution with saline. The myoglobin concentration was additionally measured with enzyme-immunoassay. In the undiluted samples there were five 'false negative' Rapi-Tex results--two in the myoglobin concentration interval 0-300 micrograms and three in the samples with myoglobin exceeding 25,000 micrograms/l--and four 'false positive' results. None of the diluted samples gave rise to false classification. Using 1:50 diluted serum, the negative predictive value of the Rapi-Tex test for identification of a myoglobin concentration greater than 5,000 micrograms/l was 0.99 (95% confidence limits 0.94-1.00), and the positive predictive value was 1.00 (0.61-1.00). Rapi-tex is concluded to be a useful emergency test for severe hypermyoglobinemia.</p>","PeriodicalId":7005,"journal":{"name":"Acta chirurgica Scandinavica","volume":"156 8","pages":"515-9"},"PeriodicalIF":0.0000,"publicationDate":"1990-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta chirurgica Scandinavica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A latex-agglutination test (Rapi-Tex) was used for semiquantitative estimation of myoglobin concentration in 89 serum samples obtained from ten patients undergoing lower-limb arterial embolectomy. Each serum sample was tested with Rapi-Tex both undiluted and after 1:50 dilution with saline. The myoglobin concentration was additionally measured with enzyme-immunoassay. In the undiluted samples there were five 'false negative' Rapi-Tex results--two in the myoglobin concentration interval 0-300 micrograms and three in the samples with myoglobin exceeding 25,000 micrograms/l--and four 'false positive' results. None of the diluted samples gave rise to false classification. Using 1:50 diluted serum, the negative predictive value of the Rapi-Tex test for identification of a myoglobin concentration greater than 5,000 micrograms/l was 0.99 (95% confidence limits 0.94-1.00), and the positive predictive value was 1.00 (0.61-1.00). Rapi-tex is concluded to be a useful emergency test for severe hypermyoglobinemia.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用乳胶凝集试验(Rapi-Tex)快速估计横纹肌溶解期间血清肌红蛋白浓度。
采用乳胶凝集试验(Rapi-Tex)半定量估计10例下肢动脉栓塞切除术患者89份血清样本中的肌红蛋白浓度。用Rapi-Tex检测每个血清样本,包括未稀释的和1:50稀释后的生理盐水。另外用酶免疫法测定肌红蛋白浓度。在未稀释的样品中,有5个Rapi-Tex结果为“假阴性”——2个在肌红蛋白浓度区间为0-300微克,3个在肌红蛋白浓度超过25000微克/升的样品中——4个结果为“假阳性”。稀释后的样品均未产生错误分类。使用1:50稀释的血清,Rapi-Tex试验鉴别肌红蛋白浓度大于5000微克/升的阴性预测值为0.99(95%置信限0.94-1.00),阳性预测值为1.00(0.61-1.00)。Rapi-tex被认为是严重高肌红蛋白血症的一种有用的紧急试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Idiopathic retroperitoneal fibrosis. Atrial septal defects. Prevention of adhesions by high molecular weight dextran in rats. Re-evaluation in nine experiments. Relevant factors in the prognosis of ductal pancreatic carcinoma. A comparison of polypropylene mesh, expanded polytetrafluoroethylene patch and polyglycolic acid mesh for the repair of experimental abdominal wall defects.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1