Experimental Analysis of an Innovative Double Strap Joint Splicing of GFRP Bars by NSM Methods for Strengthening RC Beams

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2023-09-18 DOI:10.3311/ppci.22681
Slobodan Ranković, Radomir Folić, Andrija Zorić, Todor Vacev, Žarko Petrović, Dušan Kovačević
{"title":"Experimental Analysis of an Innovative Double Strap Joint Splicing of GFRP Bars by NSM Methods for Strengthening RC Beams","authors":"Slobodan Ranković, Radomir Folić, Andrija Zorić, Todor Vacev, Žarko Petrović, Dušan Kovačević","doi":"10.3311/ppci.22681","DOIUrl":null,"url":null,"abstract":"The double strap joint splicing of glass fiber reinforced polymer (GFRP) bars for reinforced concrete (RC) beams strengthening, applying the near surface mounting (NSM) method, has been proposed in the paper. The proposed method consists of application of the supplementary GFRP bars symmetrically positioned in the cut-off zone of the main GFRP reinforcement. The performances of this splicing method have been experimentally tested for the most unfavorable case of the GFRP reinforcement cut-off in the maximal bending moment zones. During the experiment, the varied parameter has been overlapping length of the bars, taking values of 20∅ and 40∅. Evaluation of the splicing technique is done comparing the experimental results with the results of the behavior of beams strengthened by GFRP bars without cut-off and with cut-off, but without splicing. Experimental research encompassed analysis of strength, stiffness, ductility, crack pattern, strains in the steel, GFRP reinforcement and concrete, and the failure modes of the beams. It has been shown that in case of the cut-off of the GFRP bar, strengthening effectivity decreases for 39%, and that in the case of bypassing the cut-off using double strap 20∅ and 40∅ long, strengthening effectivity decreased 23%, and 14% respectively, compared to the beam without GFRP bar cut-off. Using extrapolation, it has been shown that double strap with length of 60∅ provided strength equivalent to the case without cut-off. The result of application of this splicing method of the additional GFRP bars is significant increase of strength and serviceability of the strengthened RC beams.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3311/ppci.22681","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The double strap joint splicing of glass fiber reinforced polymer (GFRP) bars for reinforced concrete (RC) beams strengthening, applying the near surface mounting (NSM) method, has been proposed in the paper. The proposed method consists of application of the supplementary GFRP bars symmetrically positioned in the cut-off zone of the main GFRP reinforcement. The performances of this splicing method have been experimentally tested for the most unfavorable case of the GFRP reinforcement cut-off in the maximal bending moment zones. During the experiment, the varied parameter has been overlapping length of the bars, taking values of 20∅ and 40∅. Evaluation of the splicing technique is done comparing the experimental results with the results of the behavior of beams strengthened by GFRP bars without cut-off and with cut-off, but without splicing. Experimental research encompassed analysis of strength, stiffness, ductility, crack pattern, strains in the steel, GFRP reinforcement and concrete, and the failure modes of the beams. It has been shown that in case of the cut-off of the GFRP bar, strengthening effectivity decreases for 39%, and that in the case of bypassing the cut-off using double strap 20∅ and 40∅ long, strengthening effectivity decreased 23%, and 14% respectively, compared to the beam without GFRP bar cut-off. Using extrapolation, it has been shown that double strap with length of 60∅ provided strength equivalent to the case without cut-off. The result of application of this splicing method of the additional GFRP bars is significant increase of strength and serviceability of the strengthened RC beams.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型GFRP筋双带拼接法加固RC梁的试验分析
采用近表面安装法,提出了玻璃纤维增强聚合物(GFRP)钢筋双带接缝拼接加固钢筋混凝土梁的方法。所提出的方法包括在GFRP主筋的截止区域对称地应用辅助GFRP筋。在GFRP筋在最大弯矩区切断的最不利情况下,对这种拼接方法的性能进行了试验测试。在实验过程中,各参数重叠条形图的长度,取值分别为20∅和40∅。将试验结果与不截断和截断不截断GFRP筋加固梁的性能结果进行比较,对拼接技术进行了评价。试验研究包括强度、刚度、延性、裂缝模式、钢、玻璃钢加固和混凝土的应变分析,以及梁的破坏模式。研究结果表明,玻璃钢隔断时,加固效果下降39%;采用双带20∅和40∅长绕过隔断时,加固效果比不设玻璃钢隔断的梁分别下降23%和14%。通过外推可知,长度为60∅的双表带在不切断的情况下提供与表壳等效的强度。采用这种附加GFRP筋的拼接方法,加固后的钢筋混凝土梁的强度和使用性能明显提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Management of Cholesteatoma: Hearing Rehabilitation. Congenital Cholesteatoma. Evaluation of Cholesteatoma. Management of Cholesteatoma: Extension Beyond Middle Ear/Mastoid. Recidivism and Recurrence.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1