Computer-guided cranioplasty using ultra-high molecular weight polyethylene patient-specific implants: a case series

IF 0.7 Q4 CLINICAL NEUROLOGY Egyptian journal of neurosurgery Pub Date : 2023-10-25 DOI:10.1186/s41984-023-00239-4
Mariam S. K. Abdelwahed, Mamdouh S. Ahmed, Ahmed S. Kamel Abdelwahed, Mohamed M. Aziz
{"title":"Computer-guided cranioplasty using ultra-high molecular weight polyethylene patient-specific implants: a case series","authors":"Mariam S. K. Abdelwahed, Mamdouh S. Ahmed, Ahmed S. Kamel Abdelwahed, Mohamed M. Aziz","doi":"10.1186/s41984-023-00239-4","DOIUrl":null,"url":null,"abstract":"Abstract Introduction Cranioplasty is the surgical correction of a cranial defect. Three-dimensional software designs have allowed patient-specific single-step cranial reconstruction for neuroprotection and cosmesis. Ultra-high molecular weight polyethylene for partial or total bone replacement has been recently introduced as a promising material for cranioplasty. The objectives of this study are to evaluate the complications and esthetic results concerning the use of ultra-high molecular weight polyethylene patient-specific implants in craniectomy patients. Methods We report a series of nine patients with cranial defects from a previous craniectomy, or patients eligible for simultaneous craniectomy and cranioplasty via computer designed ultra-high molecular weight polyethylene patient-specific implants. We have analyzed the complications and cosmetic outcomes over a course of six months. Results None of the cases developed infection, extra/subdural hematoma, cerebrospinal fluid leak, or implant failure. Three cases had postoperative sequalae: The first patient had mild postoperative seroma which subsided after medical therapy and compression, the second showed wound breakdown due to tumor metastasis and recurrence but did not necessitate implant removal, while the third sequela was a subgaleal hematoma which was aspirated, and the patient healed uneventfully afterward. Esthetic results were highly satisfactory in 75% of the patients (good patient acceptance without touch-ups). Conclusion Ultra-high molecular weight polyethylene is in all respects suitable for primary and secondary cranioplasty, combined with computer-aided manufacturing–computer-aided design techniques, excellent esthetic and functional results were achieved. However, proper preoperative planning is important, and we recommend further prospective studies with larger number of patients followed up for longer periods for better assessment.","PeriodicalId":72881,"journal":{"name":"Egyptian journal of neurosurgery","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian journal of neurosurgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s41984-023-00239-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Introduction Cranioplasty is the surgical correction of a cranial defect. Three-dimensional software designs have allowed patient-specific single-step cranial reconstruction for neuroprotection and cosmesis. Ultra-high molecular weight polyethylene for partial or total bone replacement has been recently introduced as a promising material for cranioplasty. The objectives of this study are to evaluate the complications and esthetic results concerning the use of ultra-high molecular weight polyethylene patient-specific implants in craniectomy patients. Methods We report a series of nine patients with cranial defects from a previous craniectomy, or patients eligible for simultaneous craniectomy and cranioplasty via computer designed ultra-high molecular weight polyethylene patient-specific implants. We have analyzed the complications and cosmetic outcomes over a course of six months. Results None of the cases developed infection, extra/subdural hematoma, cerebrospinal fluid leak, or implant failure. Three cases had postoperative sequalae: The first patient had mild postoperative seroma which subsided after medical therapy and compression, the second showed wound breakdown due to tumor metastasis and recurrence but did not necessitate implant removal, while the third sequela was a subgaleal hematoma which was aspirated, and the patient healed uneventfully afterward. Esthetic results were highly satisfactory in 75% of the patients (good patient acceptance without touch-ups). Conclusion Ultra-high molecular weight polyethylene is in all respects suitable for primary and secondary cranioplasty, combined with computer-aided manufacturing–computer-aided design techniques, excellent esthetic and functional results were achieved. However, proper preoperative planning is important, and we recommend further prospective studies with larger number of patients followed up for longer periods for better assessment.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用超高分子量聚乙烯患者特异性植入物的计算机引导颅骨成形术:一个案例系列
颅骨成形术是一种对颅骨缺损进行矫正的手术。三维软件设计允许针对患者的神经保护和美容的单步颅骨重建。超高分子量聚乙烯作为一种很有前途的颅骨成形术材料,近年来被广泛应用于部分或全部骨置换。本研究的目的是评估在颅骨切除术患者中使用超高分子量聚乙烯患者特异性植入物的并发症和美观效果。方法:我们报告了9例因先前颅骨切除术而出现颅骨缺损的患者,或通过计算机设计的超高分子量聚乙烯患者特异性植入物同时进行颅骨切除术和颅骨成形术的患者。我们分析了六个月的并发症和美容结果。结果所有病例均无感染、硬膜外/硬膜下血肿、脑脊液漏、植入物失效。3例患者有术后后遗症:1例患者术后出现轻度血肿,经药物治疗和压迫后消退;2例患者因肿瘤转移和复发出现创面破裂,但不需要取出植入物;3例患者术后出现无骨瓣下血肿,经抽吸后痊愈。75%的患者的美学结果非常满意(患者接受度良好,无需补片)。结论超高分子量聚乙烯在初次和二次颅骨成形术中均适用,结合计算机辅助制造-计算机辅助设计技术,可获得良好的美观和功能效果。然而,适当的术前计划是重要的,我们建议进一步的前瞻性研究,对更多的患者进行更长时间的随访,以更好地评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
32 weeks
期刊最新文献
Multidisciplinary team approach in management of anterior spinal dysraphism with unusual presentation: case series and surgical approach Analysis of moderate and severe traumatic brain injury associated with skull base fracture: a local tertiary center experience Conventional and old endovascular techniques for vertebral aneurysms still work in the era of flow diversion Possible effects of lumbar stabilization surgery on sagittal alignment, disability and quality of life Role of intraoperative cranial ultrasonography in detection of residual brain lesions during surgery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1