I. A. Paramonova, A. G. Volkov, N. Zh. Dikopova, M. S. Podporin, Yu. O. Paramonov, I. A. Nikolskaya
{"title":"Study of the antibacterial efficacy of an antiseptic drug activated by low-frequency and high-frequency ultrasound in an experiment","authors":"I. A. Paramonova, A. G. Volkov, N. Zh. Dikopova, M. S. Podporin, Yu. O. Paramonov, I. A. Nikolskaya","doi":"10.33667/2078-5631-2023-20-50-55","DOIUrl":null,"url":null,"abstract":"The aim of the work was an experimental study of the effectiveness of activation of an antiseptic drug, using low-frequency and high-frequency ultrasound, against pathogenic microorganisms obtained from periodontal pockets. As a result of automatic cultivation of clinical strains: S. sanguis, P. intermedia, C. albicans, revealed more pronounced antimicrobial effect of Miramistin activated by low-frequency ultrasound (26.5 kHz) compared with the activation of this drug by high-frequency ultrasound (880 kHz). In the treatment of inflammatory periodontal diseases, in order to obtain a pronounced antimicrobial effect, preference should be given to the combined effects of low-frequency ultrasound and the antiseptic drug Miramistin 0.01%.","PeriodicalId":499576,"journal":{"name":"Medicinskij alfavit","volume":"76 2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicinskij alfavit","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33667/2078-5631-2023-20-50-55","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The aim of the work was an experimental study of the effectiveness of activation of an antiseptic drug, using low-frequency and high-frequency ultrasound, against pathogenic microorganisms obtained from periodontal pockets. As a result of automatic cultivation of clinical strains: S. sanguis, P. intermedia, C. albicans, revealed more pronounced antimicrobial effect of Miramistin activated by low-frequency ultrasound (26.5 kHz) compared with the activation of this drug by high-frequency ultrasound (880 kHz). In the treatment of inflammatory periodontal diseases, in order to obtain a pronounced antimicrobial effect, preference should be given to the combined effects of low-frequency ultrasound and the antiseptic drug Miramistin 0.01%.