Effect of adhesive primer application on shear bond strength of self-adhesive cement to tooth structure and two different CAD/CAM milled blocks

Q3 Dentistry Brazilian Dental Science Pub Date : 2023-01-01 DOI:10.4322/bds.2023.e3978
Moamin I. ISSA, Marwah Ismael ABDULAZEEZ, Abdalbseet A. FATALLA
{"title":"Effect of adhesive primer application on shear bond strength of self-adhesive cement to tooth structure and two different CAD/CAM milled blocks","authors":"Moamin I. ISSA, Marwah Ismael ABDULAZEEZ, Abdalbseet A. FATALLA","doi":"10.4322/bds.2023.e3978","DOIUrl":null,"url":null,"abstract":"Objective: This study was conducted to evaluate the influence of the G-CEM ONE adhesive enhancing primer on the shear bond strength of self-adhesive resin cement (G-CEM ONE) to both tooth structure and two different CAD/ CAM blocks (GC Initial LiSi and Cerasmart 270). Material and Methods: Forty specimens (cylindrical-shaped, 5 mm in diameter and height) were milled from both CAD/CAM blocks (20 specimens from each block type). Forty sound upper premolars were sectioned to the level of peripheral dentin, then randomly divided into four groups (n = 10): A1: GC Initial LiSi without adhesive enhancing primer; B1: Cerasmart 270 without adhesive enhancing primer; A2: GC Initial LiSi with adhesive enhancing primer; B2: Cerasmart 270 group with adhesive enhancing primer application. The CAD/CAM blocks were cemented on teeth using a self-adhesive resin cement (G-cem one). The shear bond strength was assessed using a computerized universal testing machine. A digital microscope was used to study the mode of failure. The shear bond strength values data were analyzed statistically using paired t-test and independent t-test at the significance level of (0.05). Results: A significant difference was shown in the shear bond strength values among groups (P =0.000). The highest shear bond strength value was revealed in group A2, while group B1 exhibited the lowest shear bond strength value. Conclusion: Using the adhesive enhancing primer on the tooth’s surface improved the resin cement’s bond strength to CAD/CAM blocks. Additionally, GC Initial LiSi exhibited higher bond strength than Cerasmart 270, with or without the primer. KEYWORDS Adhesive; CAD/CAM; Dentin; Resin cement; Shear strength.","PeriodicalId":37577,"journal":{"name":"Brazilian Dental Science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Dental Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4322/bds.2023.e3978","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study was conducted to evaluate the influence of the G-CEM ONE adhesive enhancing primer on the shear bond strength of self-adhesive resin cement (G-CEM ONE) to both tooth structure and two different CAD/ CAM blocks (GC Initial LiSi and Cerasmart 270). Material and Methods: Forty specimens (cylindrical-shaped, 5 mm in diameter and height) were milled from both CAD/CAM blocks (20 specimens from each block type). Forty sound upper premolars were sectioned to the level of peripheral dentin, then randomly divided into four groups (n = 10): A1: GC Initial LiSi without adhesive enhancing primer; B1: Cerasmart 270 without adhesive enhancing primer; A2: GC Initial LiSi with adhesive enhancing primer; B2: Cerasmart 270 group with adhesive enhancing primer application. The CAD/CAM blocks were cemented on teeth using a self-adhesive resin cement (G-cem one). The shear bond strength was assessed using a computerized universal testing machine. A digital microscope was used to study the mode of failure. The shear bond strength values data were analyzed statistically using paired t-test and independent t-test at the significance level of (0.05). Results: A significant difference was shown in the shear bond strength values among groups (P =0.000). The highest shear bond strength value was revealed in group A2, while group B1 exhibited the lowest shear bond strength value. Conclusion: Using the adhesive enhancing primer on the tooth’s surface improved the resin cement’s bond strength to CAD/CAM blocks. Additionally, GC Initial LiSi exhibited higher bond strength than Cerasmart 270, with or without the primer. KEYWORDS Adhesive; CAD/CAM; Dentin; Resin cement; Shear strength.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
粘接底漆对自粘水泥与牙结构及两种不同CAD/CAM磨块剪切结合强度的影响
目的:研究G-CEM ONE粘结增强底漆对自粘树脂水泥(G-CEM ONE)与牙齿结构和两种不同CAD/ CAM块(GC Initial LiSi和Cerasmart 270)剪切结合强度的影响。材料和方法:从两个CAD/CAM块中铣削40个样品(直径和高度均为5mm)(每个块类型各20个样品)。选取健康上前磨牙40颗,切片至外周牙本质水平,随机分为4组(n = 10): A1组:GC Initial LiSi,无粘结增强底物;B1:不带增强底漆的Cerasmart 270;A2: GC Initial LiSi,带增强粘合剂底漆;B2:涂有增强粘合剂底漆的Cerasmart 270组。使用一种自粘树脂水泥(G-cem)将CAD/CAM块粘接在牙齿上。采用计算机化万能试验机对剪切粘结强度进行评估。利用数码显微镜对其失效模式进行了研究。剪切强度数据采用配对t检验和独立t检验,显著性水平为(0.05)。结果:各组间剪切粘结强度值差异有统计学意义(P =0.000)。A2组抗剪强度值最高,B1组抗剪强度值最低。结论:在牙体表面使用粘结增强底漆,可提高树脂水泥与CAD/CAM块的粘结强度。此外,无论是否添加引物,GC Initial LiSi的结合强度都高于Cerasmart 270。关键词粘合剂;CAD / CAM;牙本质;树脂水泥;抗剪强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Brazilian Dental Science
Brazilian Dental Science Dentistry-Dentistry (all)
CiteScore
1.60
自引率
0.00%
发文量
75
审稿时长
16 weeks
期刊介绍: The Journal BRAZILIAN DENTAL SCIENCE is a trimonthly scientific publication of the Institute of Science and Technology of São José dos Campos - UNESP. MISSION - To disseminate and promote the interchange of scientific information amongst the national and international dental community, by means of basic and applied research.
期刊最新文献
Stress distribution in lower second molar mesialization using mini-implants: a pilot study using 3D finite element analysis Clinical study of different composite resin systems in Class I cavities (an 18-month randomized clinical trial) Antimicrobial efficacy of S-PRG containing toothpastes on S. mutans biofilm development The possible association between the types of soft palate and gag reflex: a preliminary study UV-C light as an alternative for disinfecting orthodontic pliers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1