Pengaruh Konsentrasi Dosis Injeksi 99TCM–MDP Terhadap Kualitas Citra Kedokteran Nuklir pada Pemeriksaan Bone Scan

Febria Anita, Yadi Isma Nuryadi, Samsun Samsun, Ni Larasati Kartika Sari, Muzilman Muslim
{"title":"Pengaruh Konsentrasi Dosis Injeksi 99TCM–MDP Terhadap Kualitas Citra Kedokteran Nuklir pada Pemeriksaan Bone Scan","authors":"Febria Anita, Yadi Isma Nuryadi, Samsun Samsun, Ni Larasati Kartika Sari, Muzilman Muslim","doi":"10.47313/jig.v26i1.2569","DOIUrl":null,"url":null,"abstract":"Research has been conducted measuring the effect of the dose concentration of syringes on the image of nuclear medicine in order to determine how much influence the dose concentration of syringes has on the image of nuclear medicine. The study was carried out on 35 patients by calculating using the half-life formula and residual dose measurements on syringes that had been used for injection using a dose calibrator. The average residual dose in the syringe was 1.488 mCi, the minimum dose was 0.442 mCi, and the maximum dose of 8.550 mCi. The average activity of the 99Tcm – MDP source injected on a bone scan examination was 11.980 mCi, the average value of postero anterior lumbar vertebrae organ pixels was 37,543, the minimum pixel value was 14,238 and the maximum pixel value was 76,524. The effect of injection dose concentration is seen in the measurement of postero anterior lumbar vertebrae organ with a pixel value of at least 14,238 pixels or 32.23% of the maximum pixel value, influencing the nuclear image, according to the European Association of Nuclear Medicine EANM standard where the vertebral picture is not clear and the visualization of the spinal details in the posterior picture is less clear, the intervertebral disc is less explicit, the appearance of the bone in the sacral region and the iliac sacro joint in the posterior view appears slightly drear. However, the dosage range for patients does not exceed 20 mCi.","PeriodicalId":477861,"journal":{"name":"Jurnal Ilmiah Giga","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Ilmiah Giga","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47313/jig.v26i1.2569","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Research has been conducted measuring the effect of the dose concentration of syringes on the image of nuclear medicine in order to determine how much influence the dose concentration of syringes has on the image of nuclear medicine. The study was carried out on 35 patients by calculating using the half-life formula and residual dose measurements on syringes that had been used for injection using a dose calibrator. The average residual dose in the syringe was 1.488 mCi, the minimum dose was 0.442 mCi, and the maximum dose of 8.550 mCi. The average activity of the 99Tcm – MDP source injected on a bone scan examination was 11.980 mCi, the average value of postero anterior lumbar vertebrae organ pixels was 37,543, the minimum pixel value was 14,238 and the maximum pixel value was 76,524. The effect of injection dose concentration is seen in the measurement of postero anterior lumbar vertebrae organ with a pixel value of at least 14,238 pixels or 32.23% of the maximum pixel value, influencing the nuclear image, according to the European Association of Nuclear Medicine EANM standard where the vertebral picture is not clear and the visualization of the spinal details in the posterior picture is less clear, the intervertebral disc is less explicit, the appearance of the bone in the sacral region and the iliac sacro joint in the posterior view appears slightly drear. However, the dosage range for patients does not exceed 20 mCi.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
注射99厘米(MDP)的浓度对骨扫描中核医学图像质量的影响
为了确定注射器的剂量浓度对核医学图像的影响程度,研究了注射器的剂量浓度对核医学图像的影响。研究人员利用半衰期公式计算了35例患者,并使用剂量校准器测量了用于注射的注射器的剩余剂量。注射器中平均残留剂量为1.488 mCi,最小残留剂量为0.442 mCi,最大残留剂量为8.550 mCi。骨扫描检查99Tcm - MDP源的平均活度为11.980 mCi,腰椎后前段器官像元平均值为37543,最小像元值为14238,最大像元值为76524。注射剂量浓度的影响体现在腰椎后前器官的测量中,像素值至少为14,238像素或最大像素值的32.23%,影响核图像,根据欧洲核医学协会EANM标准,其中椎体图像不清晰,后图像中脊柱细节的可视化不太清楚,椎间盘不太明确。骶骨区域和髂骶骨关节的后视图看起来有点暗淡。然而,患者的剂量范围不超过20mci。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
PERANCANGAN SISTEM PENDETEKSI DAN PENANGGULANGAN BANJIR MENGGUNAKAN ESP32 BERBASIS IOT Prediksi Penyebaran COVID-19 dengan SIR Model Rancang Bangun Mesin Refill Cat Semprot Pengaruh Konsentrasi Dosis Injeksi 99TCM–MDP Terhadap Kualitas Citra Kedokteran Nuklir pada Pemeriksaan Bone Scan Perancangan Antena Komunikasi Selular Generasi ke-5 pada Frekuensi 2.350 MHz di Indonesia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1