Indoor ozone exposures.

C J Weschler, H C Shields, D V Naik
{"title":"Indoor ozone exposures.","authors":"C J Weschler, H C Shields, D V Naik","doi":"10.1080/08940630.1989.10466650","DOIUrl":null,"url":null,"abstract":"Indoor and outdoor ozone concentrations were measured from late May through October at three office buildings with very different ventilation rates. The indoor values closely tracked the outdoor values, and, depending on the ventilation rate, were 20 to 80 percent of those outdoors. The indoor/outdoor data are adequately described with a mass balance model. The model can also be coupled with reported air exchange rates to estimate indoor/outdoor ratios for other structures. The results from this and previous studies indicate that indoor concentrations are frequently a significant fraction of outdoor values. These observations, and the fact that most people spend greater than 90 percent of their time indoors, indicate that indoor ozone exposure (concentration X time) is greater than outdoor exposure for many people. Relatively inexpensive strategies exist to reduce indoor ozone levels, and these could be implemented to reduce the public's total ozone exposure.","PeriodicalId":77731,"journal":{"name":"JAPCA","volume":"39 12","pages":"1562-8"},"PeriodicalIF":0.0000,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/08940630.1989.10466650","citationCount":"154","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JAPCA","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08940630.1989.10466650","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 154

Abstract

Indoor and outdoor ozone concentrations were measured from late May through October at three office buildings with very different ventilation rates. The indoor values closely tracked the outdoor values, and, depending on the ventilation rate, were 20 to 80 percent of those outdoors. The indoor/outdoor data are adequately described with a mass balance model. The model can also be coupled with reported air exchange rates to estimate indoor/outdoor ratios for other structures. The results from this and previous studies indicate that indoor concentrations are frequently a significant fraction of outdoor values. These observations, and the fact that most people spend greater than 90 percent of their time indoors, indicate that indoor ozone exposure (concentration X time) is greater than outdoor exposure for many people. Relatively inexpensive strategies exist to reduce indoor ozone levels, and these could be implemented to reduce the public's total ozone exposure.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
室内臭氧暴露。
研究人员在5月下旬至10月期间测量了三座通风率不同的办公大楼的室内和室外臭氧浓度。室内值与室外值密切相关,根据通风率的不同,室内值是室外值的20%到80%。用质量平衡模型充分描述了室内/室外数据。该模型还可以与报告的空气交换率相结合,以估计其他结构的室内/室外比率。本研究和以前的研究结果表明,室内浓度往往是室外浓度的很大一部分。这些观察结果,以及大多数人90%以上的时间都呆在室内的事实表明,对许多人来说,室内臭氧暴露(浓度X时间)大于室外暴露。有一些相对便宜的策略可以降低室内臭氧水平,这些策略可以用来减少公众的臭氧暴露总量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The superfund remedial action decision process: a review of fifty records of decision. Indoor ozone exposures. Particulate and nicotine sampling in public facilities and offices. Air levels and mutagenicity of PM-10 in an indoor ice arena. Summary of the 1989 EPA/A&WMA International symposium: measurement of toxic and related air pollutants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1