Mingxian Chen MD, Zhihong Wu MD, Lin Hu MD, Xuping Li MD, Hui Yang MD, Zhenjiang Liu MD, Yichao Xiao MD, Qiming Liu MD, Shenghua Zhou MD
{"title":"The effectiveness and safety of temporary transvenous cardiac pacing leads placement into coronary sinus vein in patients with sick sinus syndrome","authors":"Mingxian Chen MD, Zhihong Wu MD, Lin Hu MD, Xuping Li MD, Hui Yang MD, Zhenjiang Liu MD, Yichao Xiao MD, Qiming Liu MD, Shenghua Zhou MD","doi":"10.1111/anec.13099","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>The temporary pacing lead routinely is placed into right ventricular (RV), which pose a risk of dislocation and cardiac perforation.</p>\n </section>\n \n <section>\n \n <h3> Objective</h3>\n \n <p>We aim to evaluate the effectiveness and safety of temporary transvenous cardiac pacing (TTCP) leads placement into the coronary sinus vein (CSV) in patients with sick sinus syndrome (SSS).</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We investigated patients with SSS who underwent TTCP lead placement into the CSV under the guidance of X-ray between January 2013 and May 2023. Patients were randomly divided into two groups: RV group (<i>n</i> = 33) and CSV group (<i>n</i> = 22). The ordinary passive bipolar electrodes were applied in both groups. In RV groups, electrodes were placed into RV. In CSV group, electrodes were placed into CSV. We evaluated the operation duration, fluoroscopic exposure, first-attempt success rate of leads placement, pacing threshold, success rate of leads placement, rate of leads displacement, and complications.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Compared with that in RV group, the procedure time, fluoroscopic exposure was significantly prolonged, while the first-attempt success rate of lead placement was obviously increased in CSV group (both <i>p</i> < .05). Compared with that in RV group, the rate of leads displacement is lower in CSV group (both <i>p</i> < .05). There were three patients occurred cardiac perforation in RV group, but no cardiac perforation was reported in CSV group (<i>p</i> > .05).</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>TTCP leads placement into the CSV is an effective and safe strategy in patients with SSS. It indicates a high rate of pacing effectiveness with low device replacement and complication rates.</p>\n </section>\n </div>","PeriodicalId":8074,"journal":{"name":"Annals of Noninvasive Electrocardiology","volume":"29 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2023-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/anec.13099","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Noninvasive Electrocardiology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/anec.13099","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background
The temporary pacing lead routinely is placed into right ventricular (RV), which pose a risk of dislocation and cardiac perforation.
Objective
We aim to evaluate the effectiveness and safety of temporary transvenous cardiac pacing (TTCP) leads placement into the coronary sinus vein (CSV) in patients with sick sinus syndrome (SSS).
Methods
We investigated patients with SSS who underwent TTCP lead placement into the CSV under the guidance of X-ray between January 2013 and May 2023. Patients were randomly divided into two groups: RV group (n = 33) and CSV group (n = 22). The ordinary passive bipolar electrodes were applied in both groups. In RV groups, electrodes were placed into RV. In CSV group, electrodes were placed into CSV. We evaluated the operation duration, fluoroscopic exposure, first-attempt success rate of leads placement, pacing threshold, success rate of leads placement, rate of leads displacement, and complications.
Results
Compared with that in RV group, the procedure time, fluoroscopic exposure was significantly prolonged, while the first-attempt success rate of lead placement was obviously increased in CSV group (both p < .05). Compared with that in RV group, the rate of leads displacement is lower in CSV group (both p < .05). There were three patients occurred cardiac perforation in RV group, but no cardiac perforation was reported in CSV group (p > .05).
Conclusion
TTCP leads placement into the CSV is an effective and safe strategy in patients with SSS. It indicates a high rate of pacing effectiveness with low device replacement and complication rates.
期刊介绍:
The ANNALS OF NONINVASIVE ELECTROCARDIOLOGY (A.N.E) is an online only journal that incorporates ongoing advances in the clinical application and technology of traditional and new ECG-based techniques in the diagnosis and treatment of cardiac patients.
ANE is the first journal in an evolving subspecialty that incorporates ongoing advances in the clinical application and technology of traditional and new ECG-based techniques in the diagnosis and treatment of cardiac patients. The publication includes topics related to 12-lead, exercise and high-resolution electrocardiography, arrhythmias, ischemia, repolarization phenomena, heart rate variability, circadian rhythms, bioengineering technology, signal-averaged ECGs, T-wave alternans and automatic external defibrillation.
ANE publishes peer-reviewed articles of interest to clinicians and researchers in the field of noninvasive electrocardiology. Original research, clinical studies, state-of-the-art reviews, case reports, technical notes, and letters to the editors will be published to meet future demands in this field.