Distribution of the Magnetic Field in the Gap between Two Permanent Magnets: Calculated and Experimental Data and Their Applications

IF 0.4 4区 工程技术 Q4 ENGINEERING, MULTIDISCIPLINARY Instruments and Experimental Techniques Pub Date : 2023-12-04 DOI:10.1134/S0020441223060064
V. V. Osipov, A. N. Orlov, V. V. Lisenkov, R. N. Maksimov, V. A. Shitov
{"title":"Distribution of the Magnetic Field in the Gap between Two Permanent Magnets: Calculated and Experimental Data and Their Applications","authors":"V. V. Osipov,&nbsp;A. N. Orlov,&nbsp;V. V. Lisenkov,&nbsp;R. N. Maksimov,&nbsp;V. A. Shitov","doi":"10.1134/S0020441223060064","DOIUrl":null,"url":null,"abstract":"<p>Theoretical and experimental studies of the magnetic field distribution in the space between two cylindrical permanent magnets with through holes in the center have been carried out. In the middle of a space measuring 2 × 2 × 2 mm<sup>3</sup> near the symmetry axis, a magnetic field with an inhomogeneity of no more than 3% was found and one in the region of 1 × 1 × 1 mm<sup>3</sup> with less than 1% was found. Based on the calculated and experimental results, a setup for determining the Verdet constant (V) using neodymium permanent magnets was developed and manufactured. The magneto-optical constants for samples of optical ceramics from Tb<sub>2</sub>O<sub>3</sub> and Tb<sub>3</sub>Ga<sub>5</sub>O<sub>12</sub> at wavelengths of 0.628 and 1.06 µm are determined.</p>","PeriodicalId":587,"journal":{"name":"Instruments and Experimental Techniques","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instruments and Experimental Techniques","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1134/S0020441223060064","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Theoretical and experimental studies of the magnetic field distribution in the space between two cylindrical permanent magnets with through holes in the center have been carried out. In the middle of a space measuring 2 × 2 × 2 mm3 near the symmetry axis, a magnetic field with an inhomogeneity of no more than 3% was found and one in the region of 1 × 1 × 1 mm3 with less than 1% was found. Based on the calculated and experimental results, a setup for determining the Verdet constant (V) using neodymium permanent magnets was developed and manufactured. The magneto-optical constants for samples of optical ceramics from Tb2O3 and Tb3Ga5O12 at wavelengths of 0.628 and 1.06 µm are determined.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
两块永磁体之间间隙中的磁场分布:计算和实验数据及其应用
我们对两个中心有通孔的圆柱形永磁体之间空间的磁场分布进行了理论和实验研究。在靠近对称轴的 2 × 2 × 2 mm3 空间中间,发现磁场的不均匀性不超过 3%,而在 1 × 1 × 1 mm3 区域,发现磁场的不均匀性小于 1%。根据计算和实验结果,开发并制造了一套利用钕永久磁铁测定 Verdet 常数 (V) 的装置。测定了波长为 0.628 和 1.06 微米的 Tb2O3 和 Tb3Ga5O12 光学陶瓷样品的磁光常数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Instruments and Experimental Techniques
Instruments and Experimental Techniques 工程技术-工程:综合
CiteScore
1.20
自引率
33.30%
发文量
113
审稿时长
4-8 weeks
期刊介绍: Instruments and Experimental Techniques is an international peer reviewed journal that publishes reviews describing advanced methods for physical measurements and techniques and original articles that present techniques for physical measurements, principles of operation, design, methods of application, and analysis of the operation of physical instruments used in all fields of experimental physics and when conducting measurements using physical methods and instruments in astronomy, natural sciences, chemistry, biology, medicine, and ecology.
期刊最新文献
Investigation of the Thermal Outgassing from P43 Phosphor and Aerogel for Use in the Vacuum System of the SRF SKIF An Active Vibration Isolator for the Space Optical Clock Application of Glass Capillaries with an Outer Diameter of Less Than One Micrometer in a Manipulator Made Based on an Atomic Force Microscope Comparison of Phase Extraction Methods on the Example of the PN-3 Microwave Interferometer Penning Ion Source in Inertial Electrostatic Confinement Systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1