{"title":"Comparison of different internal fixation implants in the treatment of talar neck fractures: A finite element analysis.","authors":"Xin Fu, Hong-Bin Cao, Nan Li, Gui-Xin Wang, Jin-Quan He","doi":"10.52312/jdrs.2023.1280","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aimed to analyze the biomechanics of cannulated screws (CS) with or without a lateral locking plate (LLP) in talar neck fractures through a finite element analysis.</p><p><strong>Patients and methods: </strong>The computed tomography image of the talus from a healthy volunteer (adult male) was used to reconstruct a three-dimensional talar model. The method for fixing talar neck fractures with CS and an LLP was planned using computer-aided design software. Afterward, the three-dimensional models of comminuted talar neck fractures were used to simulate fixation with anteroposterior parallel dual CS, single CS+LLP, and dual CS+LLP. Finally, finite element analysis was carried out to compare the outcomes of dual CS+LLP to those of single CS+LLP and to those of using dual CS alone. The displacement and von Mises stress values of the three groups with different internal fixation were analyzed.</p><p><strong>Results: </strong>For a simple talar neck fracture, the lowest amount of displacement was obtained with CS+LLP (0.407 mm), while dual CS (0.459 mm) showed the highest amount of total displacement; the lowest amount of peak stresses was obtained with CS+LLP (5.38 MPa), while dual CS (8.749 MPa) showed the highest amount of total peak stresses. For a comminuted talar neck fracture, the lowest amount of displacement was obtained with CS+LLP (0.398 mm), while dual CS (0.408 mm) showed the highest amount of total displacement; the lowest amount of peak stresses was obtained with CS+LLP (129.9 MPa), while dual CS (205.9 MPa) showed the highest amount of peak stresses.</p><p><strong>Conclusion: </strong>Compared to the other two groups, the dual CS+LLP group had better biomechanics properties in the displacement and stress peak of the talus and implant. Thus, the use of dual CS+LLP fixation is recommended for the surgical treatment of comminuted talar neck fractures.</p>","PeriodicalId":73560,"journal":{"name":"Joint diseases and related surgery","volume":"35 1","pages":"27-35"},"PeriodicalIF":1.9000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10746907/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Joint diseases and related surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52312/jdrs.2023.1280","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/2 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: This study aimed to analyze the biomechanics of cannulated screws (CS) with or without a lateral locking plate (LLP) in talar neck fractures through a finite element analysis.

Patients and methods: The computed tomography image of the talus from a healthy volunteer (adult male) was used to reconstruct a three-dimensional talar model. The method for fixing talar neck fractures with CS and an LLP was planned using computer-aided design software. Afterward, the three-dimensional models of comminuted talar neck fractures were used to simulate fixation with anteroposterior parallel dual CS, single CS+LLP, and dual CS+LLP. Finally, finite element analysis was carried out to compare the outcomes of dual CS+LLP to those of single CS+LLP and to those of using dual CS alone. The displacement and von Mises stress values of the three groups with different internal fixation were analyzed.

Results: For a simple talar neck fracture, the lowest amount of displacement was obtained with CS+LLP (0.407 mm), while dual CS (0.459 mm) showed the highest amount of total displacement; the lowest amount of peak stresses was obtained with CS+LLP (5.38 MPa), while dual CS (8.749 MPa) showed the highest amount of total peak stresses. For a comminuted talar neck fracture, the lowest amount of displacement was obtained with CS+LLP (0.398 mm), while dual CS (0.408 mm) showed the highest amount of total displacement; the lowest amount of peak stresses was obtained with CS+LLP (129.9 MPa), while dual CS (205.9 MPa) showed the highest amount of peak stresses.

Conclusion: Compared to the other two groups, the dual CS+LLP group had better biomechanics properties in the displacement and stress peak of the talus and implant. Thus, the use of dual CS+LLP fixation is recommended for the surgical treatment of comminuted talar neck fractures.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
比较不同的内固定植入物治疗距骨颈骨折:有限元分析
研究目的本研究旨在通过有限元分析,分析带或不带外侧锁定钢板(LLP)的套管螺钉(CS)在距骨颈骨折中的生物力学:使用健康志愿者(成年男性)的距骨计算机断层扫描图像重建三维距骨模型。使用计算机辅助设计软件规划了用 CS 和 LLP 固定距骨颈骨折的方法。随后,利用粉碎性距骨颈骨折的三维模型模拟了前后平行双 CS、单 CS+LLP 和双 CS+LLP 固定。最后,进行了有限元分析,以比较双 CS+LLP 与单 CS+LLP 和单独使用双 CS 的结果。结果:对于单纯性距骨颈骨折,CS+LLP 的位移量最小(0.407 mm),而双 CS 的总位移量最大(0.459 mm);CS+LLP 的峰值应力最小(5.38 MPa),而双 CS 的总峰值应力最大(8.749 MPa)。对于粉碎性距骨颈骨折,CS+LLP 的位移量最小(0.398 毫米),而双 CS 的总位移量最大(0.408 毫米);CS+LLP 的峰值应力最小(129.9 兆帕),而双 CS 的峰值应力最大(205.9 兆帕):结论:与其他两组相比,双 CS+LLP 组在距骨和植入物的位移和应力峰值方面具有更好的生物力学特性。因此,在手术治疗粉碎性距骨颈骨折时,推荐使用 CS+LLP 双固定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.50
自引率
0.00%
发文量
0
期刊最新文献
A comparison between 3D printed models and standard 2D planning in the use of metal block augments in revision knee arthroplasty. A rare mass with atypical localization: Heterotopic ossification associated with flexor hallucis longus. Anatomical medial patellofemoral ligament reconstruction improves sport participation and activity levels in adolescents with recurrent patellar dislocation. Application of combined anesthesia with spontaneous breathing in the surgery of intertrochanteric fracture of femur in elderly patients. Chronic dislocations of the fourth and fifth carpometacarpal joints with successful treatment by ligament repair: A case report and literature review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1