Additive Manufacturing of Side-Coupled Cavity Linac Structures from Pure Copper: A First Concept

Q3 Physics and Astronomy Instruments Pub Date : 2023-12-14 DOI:10.3390/instruments7040056
Michael Mayerhofer, Stefan Brenner, Ricardo Helm, S. Gruber, Elena Lopez, Lukas Stepien, Gerald Gold, Günther Dollinger
{"title":"Additive Manufacturing of Side-Coupled Cavity Linac Structures from Pure Copper: A First Concept","authors":"Michael Mayerhofer, Stefan Brenner, Ricardo Helm, S. Gruber, Elena Lopez, Lukas Stepien, Gerald Gold, Günther Dollinger","doi":"10.3390/instruments7040056","DOIUrl":null,"url":null,"abstract":"Compared to conventional manufacturing, additive manufacturing (AM) of radio frequency (RF) cavities has the potential to reduce manufacturing costs and complexity and to enable higher performance. This work evaluates whether normal conducting side-coupled linac structures (SCCL), used worldwide for a wide range of applications, can benefit from AM. A unit cell geometry (SC) optimized for 75 MeV protons was developed. Downskins with small downskin angles α were avoided to enable manufacturing by laser powder bed fusion without support structures. SCs with different α were printed and post-processed by Hirtisation (R) (an electrochemical process) to minimize surface roughness. The required accuracy for 3 GHz SCCL (medical linacs) is achieved only for α>45∘. After a material removal of 140 µm due to Hirtisation (R), a quality factor Q0 of 6650 was achieved. This corresponds to 75% of the Q0 simulated by CST®. A 3 GHz SCCL concept consisting of 31 SCs was designed. The effective shunt impedance ZT2 simulated by CST corresponds to 60.13MΩm and is comparable to the ZT2 of SCCL in use. The reduction in ZT2 expected after Hirtisation (R) can be justified in practice by up to 70% lower manufacturing costs. However, future studies will be conducted to further increase Q0.","PeriodicalId":13582,"journal":{"name":"Instruments","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instruments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/instruments7040056","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
引用次数: 0

Abstract

Compared to conventional manufacturing, additive manufacturing (AM) of radio frequency (RF) cavities has the potential to reduce manufacturing costs and complexity and to enable higher performance. This work evaluates whether normal conducting side-coupled linac structures (SCCL), used worldwide for a wide range of applications, can benefit from AM. A unit cell geometry (SC) optimized for 75 MeV protons was developed. Downskins with small downskin angles α were avoided to enable manufacturing by laser powder bed fusion without support structures. SCs with different α were printed and post-processed by Hirtisation (R) (an electrochemical process) to minimize surface roughness. The required accuracy for 3 GHz SCCL (medical linacs) is achieved only for α>45∘. After a material removal of 140 µm due to Hirtisation (R), a quality factor Q0 of 6650 was achieved. This corresponds to 75% of the Q0 simulated by CST®. A 3 GHz SCCL concept consisting of 31 SCs was designed. The effective shunt impedance ZT2 simulated by CST corresponds to 60.13MΩm and is comparable to the ZT2 of SCCL in use. The reduction in ZT2 expected after Hirtisation (R) can be justified in practice by up to 70% lower manufacturing costs. However, future studies will be conducted to further increase Q0.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用纯铜快速制造侧耦合腔体直列加速器结构:第一个概念
与传统制造相比,射频(RF)腔体的增材制造(AM)具有降低制造成本和复杂性并实现更高性能的潜力。这项研究评估了在全球范围内广泛应用的正常导电侧耦合线性腔体结构(SCCL)是否能从 AM 中受益。针对 75 MeV 质子开发了优化的单元格几何(SC)。避免了具有小下表面角 α 的下表面,以便在没有支撑结构的情况下通过激光粉末床熔融制造。打印出不同 α 的 SC,并通过 Hirtisation (R)(一种电化学工艺)进行后处理,以尽量减少表面粗糙度。只有当 α>45∘ 时,才能达到 3 GHz SCCL(医用直列加速器)的精度要求。由于 Hirtisation (R),材料去除 140 µm 后,质量因子 Q0 达到 6650。这相当于 CST® 模拟的 Q0 的 75%。设计了一个由 31 个 SC 组成的 3 GHz SCCL 概念。CST 模拟的有效分流阻抗 ZT2 为 60.13MΩm,与使用中的 SCCL 的 ZT2 相当。在实践中,Hirtisation (R) 后预计 ZT2 的减少可以通过降低高达 70% 的制造成本来证明。不过,未来的研究将进一步提高 Q0。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Instruments
Instruments Physics and Astronomy-Instrumentation
CiteScore
2.60
自引率
0.00%
发文量
70
审稿时长
11 weeks
期刊最新文献
Red and Green Laser Powder Bed Fusion of Pure Copper in Combination with Chemical Post-Processing for RF Cavity Fabrication Improved Production of Novel Radioisotopes with Custom Energy Cyclone® Kiube High Harmonic Generation Seeding Echo-Enabled Harmonic Generation toward a Storage Ring-Based Tender and Hard X-ray-Free Electron Laser Criticality of Spray Solvent Choice on the Performance of Next Generation, Spray-Based Ambient Mass Spectrometric Ionization Sources: A Case Study Based on Synthetic Cannabinoid Forensic Evidence Microparticle Hybrid Target Simulation for keV X-ray Sources
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1