{"title":"Evaluation of mechanical properties and morphology of miniscrews Ti6Al4V cold worked versus annealed in artificial bones","authors":"Neylla Berg Gomes ,&nbsp;João Victor Francetto Paes de Almeida ,&nbsp;José Guilherme Neves ,&nbsp;Américo Bortolazzo Correr ,&nbsp;Lourenço Correr-Sobrinho ,&nbsp;Ana Rosa Costa","doi":"10.1016/j.ortho.2023.100835","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p><span>This study aimed to evaluate the influence of different manufacturing procedures (Eli annealed – hot work versus cold worked – cold work) of the raw material under mechanical properties and morphological characteristics of </span>orthodontic miniscrews (MS).</p></div><div><h3>Material and methods</h3><p>Thirty MS were randomly separated into 3 types (<em>n</em> <!-->=<!--> <span>10) according to manufacturer and manufacturing process of the raw material: type A – SIN® annealed (control group); type B – Dentfix® annealed; and, type C – Dentfix® cold worked. MI were inserted in artificial bone blocks, through the manufacturer's specific manual key attached to the digital torquemeter stabilized via custom device. Data of fracture's occurrence was performed using Fisher's exact test. Comparisons between the other two types regarding insertion torque and removal torque were performed using the Mann-Whitney test. Data of fracture torque, shear stress, normal stress and torque ratio was submitted to Kruskal Wallis and Dunn tests (</span><em>α</em> <!-->=<!--> <!-->0.05). Representative images of surface morphology and fractures were selected.</p></div><div><h3>Results</h3><p>Type C showed statistically the lowest fracture torque (N.cm) (26.11<!--> <!-->±<!--> <!-->0.41) (<em>P</em> <!-->=<!--> <!-->0.0012) and highest torque ratio (%) (98.74<!--> <!-->±<!--> <!-->0.85) (<em>P</em> <!-->=<!--> <!-->0.0007). Type C showed statistically higher calculated shear (MPa) (2,432.73<!--> <!-->±<!--> <!-->508.41) and normal stress (MPa) (1,403.86<!--> <!-->±<!--> <!-->293.39) than type B and type A, showing that they differed in relation to the mechanical strength of the material with which they were made (<em>P</em> <!-->=<!--> <!-->0.0007).</p></div><div><h3>Conclusion</h3><p>Type A fractured completely inside the most apical bone. Type B and type C fractured closer to the transmucosal profile. Cold worked process should be more prone to fractures than those annealed raw manufactured.</p></div>","PeriodicalId":45449,"journal":{"name":"International Orthodontics","volume":"22 1","pages":"Article 100835"},"PeriodicalIF":1.8000,"publicationDate":"2023-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1761722723001146","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

This study aimed to evaluate the influence of different manufacturing procedures (Eli annealed – hot work versus cold worked – cold work) of the raw material under mechanical properties and morphological characteristics of orthodontic miniscrews (MS).

Material and methods

Thirty MS were randomly separated into 3 types (n = 10) according to manufacturer and manufacturing process of the raw material: type A – SIN® annealed (control group); type B – Dentfix® annealed; and, type C – Dentfix® cold worked. MI were inserted in artificial bone blocks, through the manufacturer's specific manual key attached to the digital torquemeter stabilized via custom device. Data of fracture's occurrence was performed using Fisher's exact test. Comparisons between the other two types regarding insertion torque and removal torque were performed using the Mann-Whitney test. Data of fracture torque, shear stress, normal stress and torque ratio was submitted to Kruskal Wallis and Dunn tests (α = 0.05). Representative images of surface morphology and fractures were selected.

Results

Type C showed statistically the lowest fracture torque (N.cm) (26.11 ± 0.41) (P = 0.0012) and highest torque ratio (%) (98.74 ± 0.85) (P = 0.0007). Type C showed statistically higher calculated shear (MPa) (2,432.73 ± 508.41) and normal stress (MPa) (1,403.86 ± 293.39) than type B and type A, showing that they differed in relation to the mechanical strength of the material with which they were made (P = 0.0007).

Conclusion

Type A fractured completely inside the most apical bone. Type B and type C fractured closer to the transmucosal profile. Cold worked process should be more prone to fractures than those annealed raw manufactured.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人工骨骼中 Ti6Al4V 小型螺钉冷加工与退火的机械性能和形态评估
目的:本研究旨在评估原材料的不同制造程序(伊莱退火-热加工与冷加工-冷加工)对正畸微型螺丝(MS)机械性能和形态特征的影响:根据原材料的制造商和生产工艺,将 30 个微型螺钉随机分为 3 种类型(n=10):A 型--SIN® 退火型(对照组);B 型--Dentfix® 退火型;C 型--Dentfix® 冷加工型。通过生产商指定的手动钥匙将 MI 插入人工骨块,并通过定制装置将其连接到数字扭矩计上。骨折发生率数据采用费雪精确检验。其他两种类型在插入扭矩和移除扭矩方面的比较采用 Mann-Whitney 检验法。骨折扭矩、剪切应力、法向应力和扭矩比的数据采用 Kruskal Wallis 和 Dunn 检验(α=0.05)。选取了具有代表性的表面形态和断口图像:据统计,C 型的断裂扭矩(N.cm)最低(26.11±0.41)(P=0.0012),扭矩比(%)最高(98.74±0.85)(P=0.0007)。据统计,C 型的计算剪应力(MPa)(2,432.73±508.41)和法应力(MPa)(1,403.86±293.39)均高于 B 型和 A 型,这表明它们在制造材料的机械强度方面存在差异(P=0.0007):结论:A型完全在最顶端的骨头内断裂。结论:A 型完全在最顶端的骨内断裂,B 型和 C 型的断裂位置更靠近粘膜横断面。冷加工工艺比退火生料更容易发生断裂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Orthodontics
International Orthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.50
自引率
13.30%
发文量
71
审稿时长
26 days
期刊介绍: Une revue de référence dans le domaine de orthodontie et des disciplines frontières Your reference in dentofacial orthopedics International Orthodontics adresse aux orthodontistes, aux dentistes, aux stomatologistes, aux chirurgiens maxillo-faciaux et aux plasticiens de la face, ainsi quà leurs assistant(e)s. International Orthodontics is addressed to orthodontists, dentists, stomatologists, maxillofacial surgeons and facial plastic surgeons, as well as their assistants.
期刊最新文献
Severe anterior open bite in a Class II hyperdivergent adult patient: A case report of clear aligner orthodontic camouflage treatment Editorial Board Contents Effect of post-curing parameters and material thickness on the color stability of 3D-printed dental resins: An in vitro study Acknowledgement to our Reviewers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1