Difference of coil distribution made by finishing coils in large size aneurysm model with radiolucent coils.

IF 0.9 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL Nagoya Journal of Medical Science Pub Date : 2023-11-01 DOI:10.18999/nagjms.85.4.725
Hiroki Matsuno, Takashi Izumi, Masahiro Nishihori, Shunsaku Goto, Yoshio Araki, Kinya Yokoyama, Kenji Uda, Ryuta Saito
{"title":"Difference of coil distribution made by finishing coils in large size aneurysm model with radiolucent coils.","authors":"Hiroki Matsuno, Takashi Izumi, Masahiro Nishihori, Shunsaku Goto, Yoshio Araki, Kinya Yokoyama, Kenji Uda, Ryuta Saito","doi":"10.18999/nagjms.85.4.725","DOIUrl":null,"url":null,"abstract":"<p><p>We conducted a study to understand the characteristics of the finishing coils to select the appropriate coil for the final stage of embolization. Consequently, experimental embolization was performed on a 10 mm spherical silicone aneurysm filled with radiolucent coils, which simulated a volume embolization ratio of 20%. Nine different coils (i-ED complex ∞ SilkySoft, SilkySoft, ExtraSoft, V-Trak HyperSoft helical, Barricade 10 complex finishing, Optima complex 10 soft, Target 360 Ultra, Galaxy G3 mini, and Axium prime 3D ExtraSoft) were analyzed six times at random. After each coil insertion, indices that include area, Feret diameter, circularity, and centroid center of mass were calculated using biplane x-ray images. Furthermore, these data were analyzed using the spring constant k, which represents the stiffness of the coil. In multiple comparisons, a significant difference was observed in the area analysis. The i-ED complex ∞ SilkySoft was more widespread than Target 360 Ultra (<i>p</i> < 0.05). However, no significant differences were observed in the other indices. The spring constant k value of Target 360 Ultra was 2.5 times larger than that of the i-ED complex ∞ SilkySoft, and it negatively correlated with the area index rather than with the other indices. Notably, it was suggested that the smaller the spring constant k, the wider the distribution of the finishing coils. Although there was little difference between the coils, some coils had characteristics suggesting that good embolization could be expected using appropriate finishing coils.</p>","PeriodicalId":49014,"journal":{"name":"Nagoya Journal of Medical Science","volume":"85 4","pages":"725-732"},"PeriodicalIF":0.9000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10751489/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nagoya Journal of Medical Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.18999/nagjms.85.4.725","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

We conducted a study to understand the characteristics of the finishing coils to select the appropriate coil for the final stage of embolization. Consequently, experimental embolization was performed on a 10 mm spherical silicone aneurysm filled with radiolucent coils, which simulated a volume embolization ratio of 20%. Nine different coils (i-ED complex ∞ SilkySoft, SilkySoft, ExtraSoft, V-Trak HyperSoft helical, Barricade 10 complex finishing, Optima complex 10 soft, Target 360 Ultra, Galaxy G3 mini, and Axium prime 3D ExtraSoft) were analyzed six times at random. After each coil insertion, indices that include area, Feret diameter, circularity, and centroid center of mass were calculated using biplane x-ray images. Furthermore, these data were analyzed using the spring constant k, which represents the stiffness of the coil. In multiple comparisons, a significant difference was observed in the area analysis. The i-ED complex ∞ SilkySoft was more widespread than Target 360 Ultra (p < 0.05). However, no significant differences were observed in the other indices. The spring constant k value of Target 360 Ultra was 2.5 times larger than that of the i-ED complex ∞ SilkySoft, and it negatively correlated with the area index rather than with the other indices. Notably, it was suggested that the smaller the spring constant k, the wider the distribution of the finishing coils. Although there was little difference between the coils, some coils had characteristics suggesting that good embolization could be expected using appropriate finishing coils.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在大尺寸动脉瘤模型中使用放射线透明线圈对线圈分布进行精加工所产生的差异。
我们进行了一项研究,以了解整理线圈的特性,从而为最后阶段的栓塞选择合适的线圈。因此,我们在一个 10 毫米的球形硅动脉瘤上进行了栓塞实验,瘤内填充了放射线透明线圈,模拟了 20% 的体积栓塞率。九种不同的线圈(i-ED complex ∞ SilkySoft、SilkySoft、ExtraSoft、V-Trak HyperSoft helical、Barricade 10 complex finishing、Optima complex 10 soft、Target 360 Ultra、Galaxy G3 mini 和 Axium prime 3D ExtraSoft)被随机分析了六次。每次插入线圈后,均使用双平面 X 光图像计算包括面积、Feret 直径、圆度和质心在内的指数。此外,还使用代表线圈刚度的弹簧常数 k 对这些数据进行了分析。在多重比较中,观察到面积分析存在显著差异。i-ED complex ∞ SilkySoft 比 Target 360 Ultra 更广泛(p < 0.05)。不过,其他指数没有观察到明显差异。Target 360 Ultra 的弹簧常数 k 值是 i-ED 复合物 ∞ SilkySoft 的 2.5 倍,它与面积指数而非其他指数呈负相关。值得注意的是,弹簧常数 k 越小,整理线圈的分布范围就越广。虽然线圈之间的差异不大,但一些线圈的特性表明,使用适当的整理线圈可以获得良好的栓塞效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Nagoya Journal of Medical Science
Nagoya Journal of Medical Science MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.30
自引率
0.00%
发文量
65
审稿时长
>12 weeks
期刊介绍: The Journal publishes original papers in the areas of medical science and its related fields. Reviews, symposium reports, short communications, notes, case reports, hypothesis papers, medical image at a glance, video and announcements are also accepted. Manuscripts should be in English. It is recommended that an English check of the manuscript by a competent and knowledgeable native speaker be completed before submission.
期刊最新文献
Clinical characteristics of individuals stratified by the number of answered items on the 25-question Geriatric Locomotive Function Scale. Mycobacterium marinum infection successfully treated with oral administration of minocycline and thermotherapy. Delayed open-heart operation to remove migrated intracardiac inferior vena cava stents in a living donor liver transplantation recipient: a case report. A case of peribronchiolar metaplasia of the lung appearing as a solid nodule on computed tomography. Efficacy and safety of endovascular coil embolization for unruptured middle cerebral artery aneurysms: middle-term clinical and imaging outcomes with 3 years mean follow-up periods, a 16-year experience.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1