Evaluation of Corneal Sensitivity and Quadrature Variability in Patients with Diabetic Neuropathy.

IF 0.5 Q4 OPHTHALMOLOGY Middle East African Journal of Ophthalmology Pub Date : 2023-11-21 eCollection Date: 2022-10-01 DOI:10.4103/meajo.meajo_111_23
Pelin Kiyat, Timur Kose, Banu Gümüstas, Ozlem Barut Selver
{"title":"Evaluation of Corneal Sensitivity and Quadrature Variability in Patients with Diabetic Neuropathy.","authors":"Pelin Kiyat, Timur Kose, Banu Gümüstas, Ozlem Barut Selver","doi":"10.4103/meajo.meajo_111_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of the study was to evaluate the corneal sensitivity and its quadrature variability in patients with diabetic neuropathy (DN) diagnosed with electromyography and to compare these results with age- and sex-matched healthy individuals.</p><p><strong>Methods: </strong>The left eyes of 32 patients who applied for refraction or fundus examination and had a diagnosis of DN by electromyography in their medical history were included in this study. Corneal sensitivity was evaluated using the Cochet-Bonnet esthesiometer (Luneau, Paris) in five zones: central, nasal, superior, temporal, and inferior. The measurements of the patients were compared with the measurements of 32 age- and sex-matched healthy volunteers. Furthermore, the measurements of five corneal zones were compared with each other, and the level of correlation was investigated in each group.</p><p><strong>Results: </strong>The central corneal sensitivity values were measured as 4.12 ± 1.04 (mm) and 5.92 ± 0.14 (mm) (<i>P</i> < 0.001). While the sensitivity values at the superior, inferior, nasal, and temporal quadrants were detected as 5.85 ± 0.21, 5.85 ± 0.26, 5.94 ± 0.13, 5.93 ± 0.13, and 5.92 ± 0.14 (mm) in the control group, it was measured as 3.67 ± 0.66, 3.67 ± 0.62, 3.67 ± 0.62, and 3.89 ± 0.73 (mm) in the DN group, respectively. The corneal sensitivity values were all found to be significantly lower in the DN group (<i>P</i> < 0.001 for all parameters) at all quadrants as well as the central cornea. Furthermore, a moderate positive correlation between all five zones in the control group and a very strong positive correlation in the DN group were found in terms of the corneal quadrature sensitivity.</p><p><strong>Conclusion: </strong>The current study revealed a significant reduction in corneal sensitivity in patients with DN. In both the control group and DN group, all corneal zones showed positive correlations which show the consistency of the measurement in different quadratures. Evaluating corneal sensitivity with a Cochet-Bonnet esthesiometer might serve as a useful screening tool in detecting neuropathy development. By taking the necessary precautions, further damage can be prevented.</p>","PeriodicalId":18740,"journal":{"name":"Middle East African Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2023-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10754107/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Middle East African Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/meajo.meajo_111_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/10/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The purpose of the study was to evaluate the corneal sensitivity and its quadrature variability in patients with diabetic neuropathy (DN) diagnosed with electromyography and to compare these results with age- and sex-matched healthy individuals.

Methods: The left eyes of 32 patients who applied for refraction or fundus examination and had a diagnosis of DN by electromyography in their medical history were included in this study. Corneal sensitivity was evaluated using the Cochet-Bonnet esthesiometer (Luneau, Paris) in five zones: central, nasal, superior, temporal, and inferior. The measurements of the patients were compared with the measurements of 32 age- and sex-matched healthy volunteers. Furthermore, the measurements of five corneal zones were compared with each other, and the level of correlation was investigated in each group.

Results: The central corneal sensitivity values were measured as 4.12 ± 1.04 (mm) and 5.92 ± 0.14 (mm) (P < 0.001). While the sensitivity values at the superior, inferior, nasal, and temporal quadrants were detected as 5.85 ± 0.21, 5.85 ± 0.26, 5.94 ± 0.13, 5.93 ± 0.13, and 5.92 ± 0.14 (mm) in the control group, it was measured as 3.67 ± 0.66, 3.67 ± 0.62, 3.67 ± 0.62, and 3.89 ± 0.73 (mm) in the DN group, respectively. The corneal sensitivity values were all found to be significantly lower in the DN group (P < 0.001 for all parameters) at all quadrants as well as the central cornea. Furthermore, a moderate positive correlation between all five zones in the control group and a very strong positive correlation in the DN group were found in terms of the corneal quadrature sensitivity.

Conclusion: The current study revealed a significant reduction in corneal sensitivity in patients with DN. In both the control group and DN group, all corneal zones showed positive correlations which show the consistency of the measurement in different quadratures. Evaluating corneal sensitivity with a Cochet-Bonnet esthesiometer might serve as a useful screening tool in detecting neuropathy development. By taking the necessary precautions, further damage can be prevented.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估糖尿病神经病变患者的角膜敏感性和正交变异性。
目的:本研究旨在评估通过肌电图诊断的糖尿病神经病变(DN)患者的角膜敏感度及其正交变异性,并将这些结果与年龄和性别匹配的健康人进行比较:本研究纳入了 32 名申请屈光或眼底检查并在病史中通过肌电图诊断为 DN 的患者的左眼。使用 Cochet-Bonnet 角膜敏感度仪(Luneau,巴黎)在中央、鼻、上、颞和下五个区域对角膜敏感度进行评估。患者的测量结果与 32 名年龄和性别匹配的健康志愿者的测量结果进行了比较。此外,还对五个角膜区的测量结果进行了比较,并研究了每组测量结果的相关性:角膜中央的敏感度值分别为 4.12 ± 1.04(毫米)和 5.92 ± 0.14(毫米)(P < 0.001)。对照组上象限、下象限、鼻象限和颞象限的敏感度值分别为(5.85±0.21)、(5.85±0.26)、(5.94±0.13)、(5.93±0.13)和(5.92±0.14)(毫米),而 DN 组的敏感度值分别为(3.67±0.66)、(3.67±0.62)、(3.67±0.62)和(3.89±0.73)(毫米)。结果发现,DN 组所有象限和中央角膜的角膜敏感度值均明显较低(所有参数的 P < 0.001)。此外,在角膜四象限敏感度方面,对照组所有五个区域之间呈中度正相关,而 DN 组则呈非常强的正相关:本研究显示,DN 患者的角膜敏感度明显下降。在对照组和 DN 组中,所有角膜区都显示出正相关性,这表明不同角膜区的测量结果是一致的。使用 Cochet-Bonnet 角膜曲率计评估角膜敏感度可作为检测神经病变发展的有用筛查工具。通过采取必要的预防措施,可以避免进一步的损害。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.40
自引率
0.00%
发文量
1
期刊介绍: The Middle East African Journal of Ophthalmology (MEAJO), published four times per year in print and online, is an official journal of the Middle East African Council of Ophthalmology (MEACO). It is an international, peer-reviewed journal whose mission includes publication of original research of interest to ophthalmologists in the Middle East and Africa, and to provide readers with high quality educational review articles from world-renown experts. MEAJO, previously known as Middle East Journal of Ophthalmology (MEJO) was founded by Dr Akef El Maghraby in 1993.
期刊最新文献
Bilateral Retinal Infiltration and Ischemia as the First Presenting Sign of Chronic Myeloid Leukemia: A Case Report with Multimodal Imaging. Demographic Factors Associated with Presenting for Eye Evaluation in the Partnership for Research on Vaccines and Infectious Diseases in Liberia III Natural History Study of Ebola Virus Disease. Effect of Timing of Pars Plana Vitrectomy on Visual Outcome in Cases of Nucleus Drop during Phacoemulsification. Extranuclear DNA Variations in the Susceptibility of Glaucoma. Imaging-based Biomarkers as Predictors of Response to Anti-VEGF Therapy in Idiopathic Choroidal Neovascularization.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1