Application of a New Type of Protective Sputum Suction Device in Clinic against Cross-Infection between Medical Staff and Patients

IF 1.8 Q3 CRITICAL CARE MEDICINE Critical Care Research and Practice Pub Date : 2023-12-31 DOI:10.1155/2023/9927819
Kang Lu, Weizhou Wu, Gaomei Jin, Haixia Yang, Xiaowei Cai, Lin Li, Zanchao Chen, Lin Ren, Baoshuan Guo, Qing-feng Xue
{"title":"Application of a New Type of Protective Sputum Suction Device in Clinic against Cross-Infection between Medical Staff and Patients","authors":"Kang Lu, Weizhou Wu, Gaomei Jin, Haixia Yang, Xiaowei Cai, Lin Li, Zanchao Chen, Lin Ren, Baoshuan Guo, Qing-feng Xue","doi":"10.1155/2023/9927819","DOIUrl":null,"url":null,"abstract":"Objective. To explore the clinical application of a new type of protective sputum suction device (PSSD) in patients with tracheotomy or tracheal intubation and to evaluate the protective effect of PSSD against cross-infection between medical staffs and patients. Methods. A novel PSSD was designed which can assist closed sputum suction operation without disconnecting the ventilator. 32 patients with tracheotomy were included to study the protective effect and safety of this device. Patients’ vital signs including heart rate, respiratory rate, mean arterial pressure, and blood oxygen saturation were recorded to compare the influence of open suction and closed suction (performed with this novel device). To verify the antisplash effect of this device on airway secretions, bacterial samples were collected from the hands of the suction operators and the environment near the endotracheal tube orifice before and after the two suction processes. In addition, the satisfaction of the two suction methods was compared through the questionnaire of suction staff. Finally, with the assistance of this device, an attempt was made to complete the bronchoscopy without weaning of ventilator. Results. Compared with open sputum suction, closed sputum suction has a smaller decrease in patients’ blood oxygen saturation (P<0.05), and no significant differences in other vital signs. Compared with open sputum suction, bacteria from the hands of suction staffs and the surrounding environment of the endotracheal tube were barely detected in closed suction. A questionnaire survey of sputum suction nurses suggested that the satisfaction with use and protective effect of the closed suction were better than open suction. In addition, bronchoscopy can be successfully completed with the assistance of this device, which is not possible for other breathing tubes. Conclusion. This closed sputum suction device has little effect on the oxygen saturation of patients but has excellent protective effects for medical staff against cross-infection. It has a unique advantage that can assist in completing the fiberoptic bronchoscopy with continuous ventilator-assisted breathing.","PeriodicalId":46583,"journal":{"name":"Critical Care Research and Practice","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2023-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical Care Research and Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2023/9927819","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective. To explore the clinical application of a new type of protective sputum suction device (PSSD) in patients with tracheotomy or tracheal intubation and to evaluate the protective effect of PSSD against cross-infection between medical staffs and patients. Methods. A novel PSSD was designed which can assist closed sputum suction operation without disconnecting the ventilator. 32 patients with tracheotomy were included to study the protective effect and safety of this device. Patients’ vital signs including heart rate, respiratory rate, mean arterial pressure, and blood oxygen saturation were recorded to compare the influence of open suction and closed suction (performed with this novel device). To verify the antisplash effect of this device on airway secretions, bacterial samples were collected from the hands of the suction operators and the environment near the endotracheal tube orifice before and after the two suction processes. In addition, the satisfaction of the two suction methods was compared through the questionnaire of suction staff. Finally, with the assistance of this device, an attempt was made to complete the bronchoscopy without weaning of ventilator. Results. Compared with open sputum suction, closed sputum suction has a smaller decrease in patients’ blood oxygen saturation (P<0.05), and no significant differences in other vital signs. Compared with open sputum suction, bacteria from the hands of suction staffs and the surrounding environment of the endotracheal tube were barely detected in closed suction. A questionnaire survey of sputum suction nurses suggested that the satisfaction with use and protective effect of the closed suction were better than open suction. In addition, bronchoscopy can be successfully completed with the assistance of this device, which is not possible for other breathing tubes. Conclusion. This closed sputum suction device has little effect on the oxygen saturation of patients but has excellent protective effects for medical staff against cross-infection. It has a unique advantage that can assist in completing the fiberoptic bronchoscopy with continuous ventilator-assisted breathing.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在诊所应用新型保护性吸痰装置防止医务人员与患者交叉感染
目的探讨新型保护性吸痰装置(PSSD)在气管切开或气管插管患者中的临床应用,并评估 PSSD 对防止医务人员与患者之间交叉感染的保护作用。方法。设计了一种新型 PSSD,可在不拔出呼吸机的情况下辅助闭式吸痰操作。研究对象包括 32 名气管切开患者,以了解该装置的保护效果和安全性。记录患者的生命体征,包括心率、呼吸频率、平均动脉压和血氧饱和度,以比较开放式吸痰和封闭式吸痰(使用该新型装置进行)的影响。为验证该装置对气道分泌物的防飞溅效果,在两次抽吸过程前后,分别从抽吸操作人员的双手和气管导管口附近的环境中采集了细菌样本。此外,还通过对吸痰人员的问卷调查,比较了两种吸痰方法的满意度。最后,在该设备的辅助下,尝试在不断开呼吸机的情况下完成支气管镜检查。结果。与开放式吸痰相比,封闭式吸痰对患者血氧饱和度的影响较小(P<0.05),其他生命体征无明显差异。与开放式吸痰相比,封闭式吸痰几乎检测不到吸痰人员手上和气管导管周围环境中的细菌。一项针对吸痰护士的问卷调查显示,闭式吸痰的使用满意度和保护效果均优于开放式吸痰。此外,在该装置的辅助下,支气管镜检查可以顺利完成,而其他呼吸管道则无法做到这一点。结论这种封闭式吸痰装置对患者的血氧饱和度影响不大,但对医务人员防止交叉感染有很好的保护作用。它具有独特的优势,可以在持续呼吸机辅助呼吸的情况下协助完成纤维支气管镜检查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Critical Care Research and Practice
Critical Care Research and Practice CRITICAL CARE MEDICINE-
CiteScore
3.60
自引率
0.00%
发文量
34
审稿时长
14 weeks
期刊最新文献
Assessment of Satisfaction Levels Among Families of Intensive Care Unit Patients in Saudi Arabia: A Cross-Sectional Study. Serum Concentration at 24 h With Intensive Beta-Lactam Therapy in Sepsis and Septic Shock: A Prospective Study: Beta-Lactam Blood Levels in Sepsis. Assessing the Impact of Simulation-Based Learning on Student Satisfaction and Self-Confidence in Critical Care Medicine. A Comparison of the Outcomes of COVID-19 Vaccinated and Nonvaccinated Patients Admitted to an Intensive Care Unit in a Low-Middle-Income Country. Dyschloremia and Renal Outcomes in Critically Ill Patients With Sepsis: A Prospective Cohort Study: Dyschloremia and Renal Outcomes in Sepsis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1