{"title":"Fe3O4 nanoparticles decorated reduced graphene oxide&carbon nanotubes-based composite for sensitive detection of imatinib in plasma and urine","authors":"Nasim Naderi, B. Sabeti, F. Chekin","doi":"10.5599/jese.2145","DOIUrl":null,"url":null,"abstract":"In this study, a new reduced graphene oxide (rGO) has been synthesized via a facile and envi­ronmentally friendly process using Callicarpa maingayi leaf extract. A novel magnetic catalyst based on Fe3O4 nanoparticles-reduced graphene oxide&carbon nanotubes ((Fe3O4--(rGO&CNT)) was prepared and characterized by hydrothermal method. The Fe3O4 nanoparticles with an average size of 25 to 40 nm were placed on carbon nanotubes and reduced graphene oxide sheets, while carbon nanotubes inserted between the reduced graphene oxide sheets effectively prevented their aggregation. The (Fe3O4-(rGO&CNT) composite has a large surface area and good electrocatalytic properties, suiting for the detection and determination of imatinib (IM) anticancer drug by voltammetry method. Under opti­mi­zed conditions, good linearity was achieved in the concentration range of 0.1 to 40 μmol L-1 and the limit of detection and sensitivity were 57 nmol L-1 and 3.365 μA L μmol-1, respectively. Furthermore, the fabricated sensor demonstrated acceptable reproducible behaviour and accuracy and a high level of stability during all electrochemical tests. In addition, the proposed method was applied for the detection of IM in biological samples and the recoveries were 94.0 to 98.5 %, with relative standard deviations of 2.1 to 4.4 %.","PeriodicalId":14819,"journal":{"name":"Journal of Electrochemical Science and Engineering","volume":"272 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrochemical Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5599/jese.2145","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, a new reduced graphene oxide (rGO) has been synthesized via a facile and envi­ronmentally friendly process using Callicarpa maingayi leaf extract. A novel magnetic catalyst based on Fe3O4 nanoparticles-reduced graphene oxide&carbon nanotubes ((Fe3O4--(rGO&CNT)) was prepared and characterized by hydrothermal method. The Fe3O4 nanoparticles with an average size of 25 to 40 nm were placed on carbon nanotubes and reduced graphene oxide sheets, while carbon nanotubes inserted between the reduced graphene oxide sheets effectively prevented their aggregation. The (Fe3O4-(rGO&CNT) composite has a large surface area and good electrocatalytic properties, suiting for the detection and determination of imatinib (IM) anticancer drug by voltammetry method. Under opti­mi­zed conditions, good linearity was achieved in the concentration range of 0.1 to 40 μmol L-1 and the limit of detection and sensitivity were 57 nmol L-1 and 3.365 μA L μmol-1, respectively. Furthermore, the fabricated sensor demonstrated acceptable reproducible behaviour and accuracy and a high level of stability during all electrochemical tests. In addition, the proposed method was applied for the detection of IM in biological samples and the recoveries were 94.0 to 98.5 %, with relative standard deviations of 2.1 to 4.4 %.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于还原氧化石墨烯和碳纳米管装饰的 Fe3O4 纳米颗粒复合材料,用于灵敏检测血浆和尿液中的伊马替尼
本研究利用马缨丹叶提取物,通过简便、环保的工艺合成了一种新型还原氧化石墨烯(rGO)。通过水热法制备并表征了一种基于 Fe3O4 纳米颗粒-还原氧化石墨烯和碳纳米管((Fe3O4--(rGO&CNT))的新型磁性催化剂。在碳纳米管和还原氧化石墨烯薄片上放置了平均尺寸为 25 至 40 nm 的 Fe3O4 纳米粒子,而插入还原氧化石墨烯薄片之间的碳纳米管有效地防止了它们的聚集。Fe3O4-(rGO&CNT)复合材料具有较大的比表面积和良好的电催化性能,适用于伏安法检测和测定伊马替尼(IM)抗癌药物。在优化条件下,该传感器在 0.1 至 40 μmol L-1 的浓度范围内线性关系良好,检出限和灵敏度分别为 57 nmol L-1 和 3.365 μA L μmol-1。此外,所制作的传感器在所有电化学测试中都表现出了可接受的再现性、准确性和高度稳定性。此外,所提出的方法还被用于检测生物样品中的 IM,其回收率为 94.0% 至 98.5%,相对标准偏差为 2.1% 至 4.4%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Extended characteristic polynomial estimating the electrochemical behaviour of some 4-(azulen-1-yl)-2,6-divinylpyridine derivatives Bidens pilosa extract as a corrosion inhibitor on 1008 carbon steel in neutral medium Supercapacitive performance of self-assembled thin film of liquid catocene/basal plane pyrolytic graphite electrode Zirconia based hydrophobic coatings exhibiting excellent durability for versatile use Walnut (Juglans regia L.) fruit septum alcoholic extract as cor-rosion inhibitor for Fe B500B steel bars in mixed acidic solution
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1