Clinical and Patient Reported Outcomes of Vitamin E Diffused Highly Cross-Linked Polyethylene Liner Versus Moderately Cross-Linked Polyethylene Liner in Total Hip Arthroplasty: A Meta-Analysis

Diovince S Tan, Byron S Angeles
{"title":"Clinical and Patient Reported Outcomes of Vitamin E Diffused Highly Cross-Linked Polyethylene Liner Versus Moderately Cross-Linked Polyethylene Liner in Total Hip Arthroplasty: A Meta-Analysis","authors":"Diovince S Tan, Byron S Angeles","doi":"10.35460/2546-1621.2023-0051","DOIUrl":null,"url":null,"abstract":"Introduction: In the modern era of Medicine, total hip arthroplasty (THA) is found to last longer than ever before due to the fact that there has been improved bearing surfaces and materials available. Despite these modern approaches, failure caused by polyethylene wear, aseptic loosening, instability and mispositioning and even infection could affect THA survival. In the course of addressing anti-wear characteristics of the conventional polyethylene surface various approaches have been made. To date, there are very limited studies done in which polyethylene liner is better. General Objective: To compare the effects of vitamin E diffused highly cross-linked polyethylene liner versus moderately cross-linked polyethylene liner in THA. Methodology: Meta-analysis research design was used in this study. The primary investigators conducted a comprehensive literature search from Medline, Cochrane Library, PubMed, Elsevier, Google Scholar, Embase and ClinicalTrial.gov as electronic database. All randomized controlled trials comparing the effects of vitamin E diffused highly cross-linked polyethylene liner versus moderately cross-linked polyethylene liner in THA were included in the review. Conclusions: The investigation disclosed no statistical significance between moderately cross-linked polyethylene liner and vitamin E diffused highly cross-linked polyethylene liner in terms of migration, head penetration and wear on mediolateral, longitudinal and anteroposterior axes after 2 and 5 years of undergoing THA. Moreover, the data pertaining to patient reported outcomes and clinical outcomes measure also indicated no statistical significance between moderately cross-linked polyethylene liner and vitamin E diffused highly cross-linked polyethylene liner. This indicates that vitamin E diffused highly cross-linked polyethylene liner is comparable with the conventional moderately cross-linked polyethylene liner. Vitamin E-infused highly cross-linked polyethylene ( VEPE) showed an almost similar stability with regard to the wear rates and the component showed similar stability with that of moderately cross-linked polyethylene liner. Keywords: Moderately Cross-linked Polyethylene Liner, Vitamin E Diffused Highly Cross-linked Polyethylene Liner, Total Hip Arthroplasty","PeriodicalId":399180,"journal":{"name":"Journal of Medicine, University of Santo Tomas","volume":"29 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medicine, University of Santo Tomas","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35460/2546-1621.2023-0051","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: In the modern era of Medicine, total hip arthroplasty (THA) is found to last longer than ever before due to the fact that there has been improved bearing surfaces and materials available. Despite these modern approaches, failure caused by polyethylene wear, aseptic loosening, instability and mispositioning and even infection could affect THA survival. In the course of addressing anti-wear characteristics of the conventional polyethylene surface various approaches have been made. To date, there are very limited studies done in which polyethylene liner is better. General Objective: To compare the effects of vitamin E diffused highly cross-linked polyethylene liner versus moderately cross-linked polyethylene liner in THA. Methodology: Meta-analysis research design was used in this study. The primary investigators conducted a comprehensive literature search from Medline, Cochrane Library, PubMed, Elsevier, Google Scholar, Embase and ClinicalTrial.gov as electronic database. All randomized controlled trials comparing the effects of vitamin E diffused highly cross-linked polyethylene liner versus moderately cross-linked polyethylene liner in THA were included in the review. Conclusions: The investigation disclosed no statistical significance between moderately cross-linked polyethylene liner and vitamin E diffused highly cross-linked polyethylene liner in terms of migration, head penetration and wear on mediolateral, longitudinal and anteroposterior axes after 2 and 5 years of undergoing THA. Moreover, the data pertaining to patient reported outcomes and clinical outcomes measure also indicated no statistical significance between moderately cross-linked polyethylene liner and vitamin E diffused highly cross-linked polyethylene liner. This indicates that vitamin E diffused highly cross-linked polyethylene liner is comparable with the conventional moderately cross-linked polyethylene liner. Vitamin E-infused highly cross-linked polyethylene ( VEPE) showed an almost similar stability with regard to the wear rates and the component showed similar stability with that of moderately cross-linked polyethylene liner. Keywords: Moderately Cross-linked Polyethylene Liner, Vitamin E Diffused Highly Cross-linked Polyethylene Liner, Total Hip Arthroplasty
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
全髋关节置换术中维生素 E 扩散高交联聚乙烯内衬与中度交联聚乙烯内衬的临床和患者报告结果:元分析
导言:在现代医学时代,由于轴承表面和材料的改进,全髋关节置换术(THA)的寿命比以往任何时候都要长。尽管采用了这些现代方法,但聚乙烯磨损、无菌性松动、不稳定性和错位,甚至感染等故障仍会影响全髋关节置换术的存活率。在解决传统聚乙烯表面抗磨损特性的过程中,人们采用了各种方法。迄今为止,关于哪种聚乙烯衬垫更好的研究非常有限。总体目标:比较维生素 E 扩散高度交联聚乙烯衬垫与中度交联聚乙烯衬垫在 THA 中的效果。研究方法:本研究采用 Meta 分析研究设计。主要研究者在 Medline、Cochrane Library、PubMed、Elsevier、Google Scholar、Embase 和 ClinicalTrial.gov 等电子数据库中进行了全面的文献检索。所有比较维生素 E 扩散高度交联聚乙烯衬垫与中度交联聚乙烯衬垫在 THA 中效果的随机对照试验均被纳入综述。结论:调查显示,中度交联聚乙烯衬垫和维生素 E 扩散高交联聚乙烯衬垫在接受 THA 治疗 2 年和 5 年后,在内侧轴、纵轴和前胸轴的移位、头部穿透和磨损方面没有统计学意义。此外,与患者报告结果和临床结果测量相关的数据也表明,中度交联聚乙烯衬垫与维生素 E 扩散高交联聚乙烯衬垫之间没有统计学意义。这表明维生素 E 扩散高交联聚乙烯衬垫与传统的中度交联聚乙烯衬垫具有可比性。注入维生素 E 的高交联聚乙烯(VEPE)在磨损率方面表现出几乎相似的稳定性,其组分也表现出与中度交联聚乙烯衬里相似的稳定性。关键词中度交联聚乙烯内衬 维生素 E 扩散高交联聚乙烯内衬 全髋关节置换术
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Current Insights into Covid-19 Vaccination Effectiveness of Platelet-Rich Plasma as an Adjunct to Core Decompression to Treatment Outcomes and Femoral Head Preservation in Avascular Necrosis of the Hip: A Meta-Analysis of Randomized Controlled Trials Clinical and Patient Reported Outcomes of Vitamin E Diffused Highly Cross-Linked Polyethylene Liner Versus Moderately Cross-Linked Polyethylene Liner in Total Hip Arthroplasty: A Meta-Analysis A Review of the Clinical Significance of Lumbar Puncture in the Diagnostic Approach of Aneurysmal Subarachnoid Hemorrhage (SAH): A Case Report of CT-Negative and Lumbar Puncture–Positive SAH A Basic Review of Sarcopenia Diagnosis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1