{"title":"Corrosion risk of SO2 on silver plating of electric components","authors":"Mengmeng Zhuang, Jiayu Wang, Jiawei Zhao, Kaixu Ren, Xin Wang, Peng Liu","doi":"10.56028/aetr.8.1.203.2023","DOIUrl":null,"url":null,"abstract":"With the miniaturization and high integration of electronic devices, the reliability of the devices will be seriously reduced by the small corrosion of silver plating. As common corrosion pollutants, SO2 have strong corrosion sensitivity to silver. Using the G1 limit in ANSI/ISA 71.04 as the baseline,hour-by-hour SO2 concentration data for 210 cities show that the SO2 ranges from 1-993μg/m3, with an average of 20.80% of days ratio and 8.04% of hours ratio exceeding G1 level requirements, indicate a momentary high corrosion risk in the actual running environment. For silver plating, the corrosion risk of independent parameters conforms to the law of power function. Under the comprehensive influence of multiple factors, the corrosion thresholds of some parameters will decrease and the corrosion risk of electronic devices in service will increase.","PeriodicalId":502380,"journal":{"name":"Advances in Engineering Technology Research","volume":"38 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Engineering Technology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56028/aetr.8.1.203.2023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

With the miniaturization and high integration of electronic devices, the reliability of the devices will be seriously reduced by the small corrosion of silver plating. As common corrosion pollutants, SO2 have strong corrosion sensitivity to silver. Using the G1 limit in ANSI/ISA 71.04 as the baseline,hour-by-hour SO2 concentration data for 210 cities show that the SO2 ranges from 1-993μg/m3, with an average of 20.80% of days ratio and 8.04% of hours ratio exceeding G1 level requirements, indicate a momentary high corrosion risk in the actual running environment. For silver plating, the corrosion risk of independent parameters conforms to the law of power function. Under the comprehensive influence of multiple factors, the corrosion thresholds of some parameters will decrease and the corrosion risk of electronic devices in service will increase.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
二氧化硫对电子元件镀银的腐蚀风险
随着电子设备的微型化和高度集成化,镀银层的微小腐蚀将严重降低设备的可靠性。二氧化硫作为常见的腐蚀污染物,对银具有很强的腐蚀敏感性。以 ANSI/ISA 71.04 中的 G1 限值为基准,210 个城市的逐小时 SO2 浓度数据显示,SO2 的范围在 1-993μg/m3 之间,平均有 20.80% 的天数比和 8.04% 的小时数比超过 G1 级别要求,表明实际运行环境中存在瞬间高腐蚀风险。对于镀银而言,独立参数的腐蚀风险符合幂函数规律。在多种因素的综合影响下,部分参数的腐蚀阈值会降低,服役电子设备的腐蚀风险会增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Novel Financial Anti-fraud Method based on Machine Learning Algorithms Network Pharmacology Study on the Neurotoxic Mechanism of Acorus tatarinowii Analysis on the Growth of Shared Bike Users Based on Random Forest Model The synthesis of acetone from isobutane with the intermediate of di-tert-butyl peroxide A Blockchain-Based Intelligent Data Management Platform for Power Grid Applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1