Developing a prototype device to measure nail bed angle – An exploratory multiphasic study

Tanvi Fuletra, Nidhi Ved
{"title":"Developing a prototype device to measure nail bed angle – An exploratory multiphasic study","authors":"Tanvi Fuletra, Nidhi Ved","doi":"10.4103/kleuhsj.kleuhsj_439_22","DOIUrl":null,"url":null,"abstract":"INTRODUCTION: Digital clubbing is characterized by a focal bulbous enlargement of the terminal segments of the fingers and/or toes due to the proliferation of connective tissue between nail matrix and the distal phalanx. The purpose of this study is to develop a prototype device to measure nail bed angle with significant inter-rater and intra-rater reliability. METHODOLOGY: Assessment eligibility through inclusion and exclusion criteria. Informed consent was signed by the patient before starting the testing procedure and measurement was done using the nail bed angle measuring device in normal and patients with clubbing. RESULTS: The intraclass correlation s test shows that the device has high reliability score ranging from 0.989 to 0.993. DISCUSSION: Lovibond represented the “profile” sign in 1938, which shows the actual clubbing of the fingers if it is >180. Till the day, the Schamroth's window test is used to identify or confirm clubbing where if 2 opposing fingers are held back-to-back against each other, a diamond-shaped space should normally appear between the nail beds and the nails of the two fingers. In clubbing, this space (or window) was missing. This test was useful if the finger clubbing is present graded into class 3 or more as there will not be much angle deviation to be visible in the Schamroth's sign. CONCLUSIONS: This device can measure the angle of the nail bed which will measure the slightest deviation in angle. This device is portable, cost-effective, less time-consuming, and high in accuracy.","PeriodicalId":13457,"journal":{"name":"Indian Journal of Health Sciences and Biomedical Research (KLEU)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Health Sciences and Biomedical Research (KLEU)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/kleuhsj.kleuhsj_439_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

INTRODUCTION: Digital clubbing is characterized by a focal bulbous enlargement of the terminal segments of the fingers and/or toes due to the proliferation of connective tissue between nail matrix and the distal phalanx. The purpose of this study is to develop a prototype device to measure nail bed angle with significant inter-rater and intra-rater reliability. METHODOLOGY: Assessment eligibility through inclusion and exclusion criteria. Informed consent was signed by the patient before starting the testing procedure and measurement was done using the nail bed angle measuring device in normal and patients with clubbing. RESULTS: The intraclass correlation s test shows that the device has high reliability score ranging from 0.989 to 0.993. DISCUSSION: Lovibond represented the “profile” sign in 1938, which shows the actual clubbing of the fingers if it is >180. Till the day, the Schamroth's window test is used to identify or confirm clubbing where if 2 opposing fingers are held back-to-back against each other, a diamond-shaped space should normally appear between the nail beds and the nails of the two fingers. In clubbing, this space (or window) was missing. This test was useful if the finger clubbing is present graded into class 3 or more as there will not be much angle deviation to be visible in the Schamroth's sign. CONCLUSIONS: This device can measure the angle of the nail bed which will measure the slightest deviation in angle. This device is portable, cost-effective, less time-consuming, and high in accuracy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
开发测量甲床角度的原型设备 - 一项探索性多相研究
导言:甲沟炎的特征是手指和/或脚趾末节因甲基质和远端指骨之间的结缔组织增生而出现局灶性球状肿大。本研究的目的是开发一种测量甲床角的原型设备,该设备在评分者之间和评分者内部具有显著的可靠性。方法:通过纳入和排除标准评估资格。在测试程序开始前,患者签署知情同意书,并使用甲床角度测量仪对正常人和患有甲沟炎的患者进行测量。结果:类内相关性 s 检验表明,该装置的可靠度在 0.989 至 0.993 之间。讨论:Lovibond 于 1938 年提出了 "轮廓 "征,如果手指的轮廓大于 180,就会显示出手指的实际弯曲。时至今日,Schamroth's window 测试仍被用于识别或确认俱乐部病。如果将两个相对的手指背靠背地握在一起,通常在两个手指的甲床和指甲之间会出现一个菱形的空间。而在甲沟炎中,这一空间(或窗口)缺失。如果存在3级或3级以上的手指畸形,这项测试就很有用,因为在沙姆罗特氏征中看不到太大的角度偏差。结论:该设备可以测量甲床的角度,并能测量出最微小的角度偏差。该设备便于携带、成本效益高、耗时少、准确度高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
56
审稿时长
32 weeks
期刊最新文献
Knowledge regarding premenstrual syndrome among adolescent school girls in a view to develop an information booklet Unveiling the learning style puzzle: Factors that shape how medical students learn Association of rheumatoid factor and anti-cyclic citrullinated peptide antibody with demographic, clinical, and inflammatory parameters in rheumatoid arthritis Hard tick in female external genitalia: A rare site of tick bite Robotic surgery in otorhinolaryngology and head-and-neck oncology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1