Philip Sommer, Michael Schreinlechner, Maria Noflatscher, Clarisse Engl, Daniela Lener, Markus Theurl, Rudolf Kirchmair, Peter Marschang
{"title":"Hepatocyte growth factor as indicator for subclinical atherosclerosis.","authors":"Philip Sommer, Michael Schreinlechner, Maria Noflatscher, Clarisse Engl, Daniela Lener, Markus Theurl, Rudolf Kirchmair, Peter Marschang","doi":"10.1024/0301-1526/a001111","DOIUrl":null,"url":null,"abstract":"<p><p><b></b> <i>Background:</i> Hepatocyte growth factor (HGF) is a pleiotropic cytokine mainly produced by mesenchymal cells. After endothelial damage by oxidized low-density lipoprotein (LDL), HGF is produced and released into the circulation in response. Due to this mechanism HGF has been proposed as possible clinical biomarker for clinical as well as subclinical atherosclerosis. <i>Patients and methods:</i> The conducted study is an observational, single centre, cohort study, including 171 patients with at least one cardiovascular risk factor or already established cardiovascular disease (CVD). Each patient underwent 3D plaque volumetry of the carotid and femoral arteries as well as physical examination and record of the medical history. Additionally, plasma HGF and further laboratory parameters like high sensitivity C-reactive protein and LDL-cholesterol were determined. <i>Results:</i> 169 patients were available for statistical analysis. In bivariate correlation, HGF showed a highly significant correlation with total plaque volume (TPV, r=0.48; p<0.001). In receiver operating characteristic (ROC) analysis for high TPV, HGF showed an area under the curve (AUC) of 0.68 (CI 95%: 0.59-0.77, p<0.001) with a sensitivity of 78% and a specificity of 52% to predict high TPV at a cut-off of 959 ng/ml. In the ROC-analysis for the presence of CVD, HGF demonstrated an AUC of 0.65 (95% CI 0.55-0.73; p=0.01) with a sensitivity of 77% and a specificity of 52%. <i>Conclusions:</i> Higher plasma levels of HGF are associated with higher atherosclerotic plaque volume as measured by 3D-ultrasound.</p>","PeriodicalId":23528,"journal":{"name":"Vasa-european Journal of Vascular Medicine","volume":" ","pages":"120-128"},"PeriodicalIF":2.1000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vasa-european Journal of Vascular Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1024/0301-1526/a001111","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Hepatocyte growth factor (HGF) is a pleiotropic cytokine mainly produced by mesenchymal cells. After endothelial damage by oxidized low-density lipoprotein (LDL), HGF is produced and released into the circulation in response. Due to this mechanism HGF has been proposed as possible clinical biomarker for clinical as well as subclinical atherosclerosis. Patients and methods: The conducted study is an observational, single centre, cohort study, including 171 patients with at least one cardiovascular risk factor or already established cardiovascular disease (CVD). Each patient underwent 3D plaque volumetry of the carotid and femoral arteries as well as physical examination and record of the medical history. Additionally, plasma HGF and further laboratory parameters like high sensitivity C-reactive protein and LDL-cholesterol were determined. Results: 169 patients were available for statistical analysis. In bivariate correlation, HGF showed a highly significant correlation with total plaque volume (TPV, r=0.48; p<0.001). In receiver operating characteristic (ROC) analysis for high TPV, HGF showed an area under the curve (AUC) of 0.68 (CI 95%: 0.59-0.77, p<0.001) with a sensitivity of 78% and a specificity of 52% to predict high TPV at a cut-off of 959 ng/ml. In the ROC-analysis for the presence of CVD, HGF demonstrated an AUC of 0.65 (95% CI 0.55-0.73; p=0.01) with a sensitivity of 77% and a specificity of 52%. Conclusions: Higher plasma levels of HGF are associated with higher atherosclerotic plaque volume as measured by 3D-ultrasound.
期刊介绍:
Vasa is the European journal of vascular medicine. It is the official organ of the German, Swiss, and Slovenian Societies of Angiology.
The journal publishes original research articles, case reports and reviews on vascular biology, epidemiology, prevention, diagnosis, medical treatment and interventions for diseases of the arterial circulation, in the field of phlebology and lymphology including the microcirculation, except the cardiac circulation.
Vasa combines basic science with clinical medicine making it relevant to all physicians interested in the whole vascular field.