Evaluating the Marginal and Internal Discrepancy of Nickel-Chrome Copings Made on Fixed Partial Denture Implants with Conventional and 3D Printing Techniques.

Mohsen Ziaei, Farshad Bajoghli, Mahmoud Sabouhi, Mohammad Jowkar, Farshad Nadian, Farbod Manshaei
{"title":"Evaluating the Marginal and Internal Discrepancy of Nickel-Chrome Copings Made on Fixed Partial Denture Implants with Conventional and 3D Printing Techniques.","authors":"Mohsen Ziaei, Farshad Bajoghli, Mahmoud Sabouhi, Mohammad Jowkar, Farshad Nadian, Farbod Manshaei","doi":"10.5005/jp-journals-10024-3586","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This study aimed to evaluate the marginal and internal discrepancy of nickel-chrome (Ni-Cr) copings made on implant bridges with conventional and 3D printing techniques.</p><p><strong>Materials and methods: </strong>30 three-unit Ni-Cr FDPs (60 copings) were made by 3D-printing technique (PolyJet group), lost-wax method with die spacer technique (die spacer group), and lost-wax method with burn-out the cap (burn-out cap group). Then, the frames obtained from the three methods were checked to examine the marginal discrepancy by stereomicroscope after preparation and polishing. The silicon replica method was used to investigate the internal discrepancy at 6 points (buccal portion of occlusal surface, lingual portion of occlusal surface, middle area of the axial surface in the lingual, middle area of the axial surface in the buccal, cervico-buccal area, and cervico-lingual area). Kolmogorov-Smirnov test was performed first to estimate the normality of data distribution. A one-way ANOVA and <i>post hoc</i> Tukey test were done for comparing marginal and internal discrepancies between groups. The significant level was considered <i>p</i> < 0.05.</p><p><strong>Results: </strong>The mean ± standard deviation of marginal discrepancy in the PolyJet group, die spacer group, and burn-out cap group was 37.9 ± 15, 68.8 ± 31.8 and 42.7 ± 3.6 µm for buccal margins and 40.4 ± 12.3, 64 ± 21.7, and 42.4 ± 2.1 µm for lingual margins, respectively. The means of buccal and lingual marginal discrepancy in the burn-out cap group and PolyJet group were significantly lower than the die spacer group (<i>p</i> < 0.001). Marginal discrepancy was not statistically different between the burn-out cap group and the PolyJet group. The mean ± standard deviation of overall internal discrepancy in the PolyJet group, die spacer group, and burn-out cap group was 64.6 ± 3.7, 72 ± 22.2, and 58.7 ± 2 µm, respectively. There was a significant difference between the mean of internal discrepancy between three groups (<i>p</i> = 0.001). The mean of internal discrepancy of the burn-out cap group was significantly lower than the die spacer group (<i>p</i> = 0.001) and PolyJet group (<i>p</i> = 0.005). Internal discrepancy was not significantly different between the PolyJet group and the die spacer group (<i>p</i> = 0.168).</p><p><strong>Conclusion: </strong>The marginal and internal gap rates of the three groups were within clinically acceptable limits. The 3D printing technique and lost-wax method with burn-out the cap had the lowest buccal and lingual marginal discrepancies. The burn-out cap method had better fitness and less internal discrepancy than 3D printing and die spacer groups.</p><p><strong>Clinical significance: </strong>Lower marginal discrepancy of copings fabricated by using 3D printed patterns may improve clinical success of implant restoration. How to cite this article: Ziaei M, Bajoghli F, Sabouhi M, <i>et al</i>. Evaluating the Marginal and Internal Discrepancy of Nickel-Chrome Copings Made on Fixed Partial Denture Implants with Conventional and 3D Printing Techniques. J Contemp Dent Pract 2023;24(11):826-833.</p>","PeriodicalId":35792,"journal":{"name":"Journal of Contemporary Dental Practice","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Dental Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10024-3586","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: This study aimed to evaluate the marginal and internal discrepancy of nickel-chrome (Ni-Cr) copings made on implant bridges with conventional and 3D printing techniques.

Materials and methods: 30 three-unit Ni-Cr FDPs (60 copings) were made by 3D-printing technique (PolyJet group), lost-wax method with die spacer technique (die spacer group), and lost-wax method with burn-out the cap (burn-out cap group). Then, the frames obtained from the three methods were checked to examine the marginal discrepancy by stereomicroscope after preparation and polishing. The silicon replica method was used to investigate the internal discrepancy at 6 points (buccal portion of occlusal surface, lingual portion of occlusal surface, middle area of the axial surface in the lingual, middle area of the axial surface in the buccal, cervico-buccal area, and cervico-lingual area). Kolmogorov-Smirnov test was performed first to estimate the normality of data distribution. A one-way ANOVA and post hoc Tukey test were done for comparing marginal and internal discrepancies between groups. The significant level was considered p < 0.05.

Results: The mean ± standard deviation of marginal discrepancy in the PolyJet group, die spacer group, and burn-out cap group was 37.9 ± 15, 68.8 ± 31.8 and 42.7 ± 3.6 µm for buccal margins and 40.4 ± 12.3, 64 ± 21.7, and 42.4 ± 2.1 µm for lingual margins, respectively. The means of buccal and lingual marginal discrepancy in the burn-out cap group and PolyJet group were significantly lower than the die spacer group (p < 0.001). Marginal discrepancy was not statistically different between the burn-out cap group and the PolyJet group. The mean ± standard deviation of overall internal discrepancy in the PolyJet group, die spacer group, and burn-out cap group was 64.6 ± 3.7, 72 ± 22.2, and 58.7 ± 2 µm, respectively. There was a significant difference between the mean of internal discrepancy between three groups (p = 0.001). The mean of internal discrepancy of the burn-out cap group was significantly lower than the die spacer group (p = 0.001) and PolyJet group (p = 0.005). Internal discrepancy was not significantly different between the PolyJet group and the die spacer group (p = 0.168).

Conclusion: The marginal and internal gap rates of the three groups were within clinically acceptable limits. The 3D printing technique and lost-wax method with burn-out the cap had the lowest buccal and lingual marginal discrepancies. The burn-out cap method had better fitness and less internal discrepancy than 3D printing and die spacer groups.

Clinical significance: Lower marginal discrepancy of copings fabricated by using 3D printed patterns may improve clinical success of implant restoration. How to cite this article: Ziaei M, Bajoghli F, Sabouhi M, et al. Evaluating the Marginal and Internal Discrepancy of Nickel-Chrome Copings Made on Fixed Partial Denture Implants with Conventional and 3D Printing Techniques. J Contemp Dent Pract 2023;24(11):826-833.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用传统和 3D 打印技术评估固定部分义齿种植体上镍铬合金牙冠的边缘和内部差异。
材料和方法:采用3D打印技术(PolyJet组)、失蜡法加模具间隔技术(模具间隔组)和失蜡法加烧帽技术(烧帽组)制作30个三单位镍铬合金FDP(60个牙合)。然后,在制备和抛光后,用体视显微镜检查这三种方法得到的边框的差异。采用硅复型法检查 6 个点(咬合面的颊面部分、咬合面的舌面部分、舌面的轴面中间区域、颊面的轴面中间区域、颈颊区域和颈舌区域)的内部差异。首先进行了 Kolmogorov-Smirnov 检验,以估计数据分布的正态性。比较组间边缘和内部差异时,采用单因素方差分析和事后 Tukey 检验。显著水平为 p <0.05:PolyJet组、模具垫片组和烧蚀帽组的边缘差异平均值(±标准差)分别为:颊侧37.9±15、68.8±31.8和42.7±3.6微米;舌侧40.4±12.3、64±21.7和42.4±2.1微米。烧蚀帽组和 PolyJet 组的颊舌边缘差异均值明显低于模具间隔组(p < 0.001)。烧坏帽组和 PolyJet 组的边缘差异无统计学差异。PolyJet 组、模具垫片组和烧蚀帽组的整体内部差异的平均值(± 标准差)分别为 64.6 ± 3.7、72 ± 22.2 和 58.7 ± 2 µm。三组之间的内部差异平均值有明显差异(p = 0.001)。烧蚀帽组的内偏差平均值明显低于模具垫片组(p = 0.001)和 PolyJet 组(p = 0.005)。PolyJet 组与模具垫片组的内部差异无明显差异(p = 0.168):结论:三组患者的边缘间隙率和内部间隙率都在临床可接受的范围内。三维打印技术和烧帽失蜡法的颊侧和舌侧边缘差最小。与三维打印技术组和模具垫片组相比,烧帽法的适应性更好,内侧间隙更小:临床意义:使用三维打印模式制作的牙冠边缘差更小,可以提高种植修复的临床成功率。本文引用方式Ziaei M, Bajoghli F, Sabouhi M, et al. Evaluating the Marginal and Internal Discrepancy of Nickel-Chrome Coping Made on Fixed Partial Dent Dearing Implants with Conventional and 3D Printing Techniques.J Contemp Dent Pract 2023;24(11):826-833.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Contemporary Dental Practice
Journal of Contemporary Dental Practice Dentistry-Dentistry (all)
CiteScore
1.80
自引率
0.00%
发文量
174
期刊介绍: The Journal of Contemporary Dental Practice (JCDP), is a peer-reviewed, open access MEDLINE indexed journal. The journal’s full text is available online at http://www.thejcdp.com. The journal allows free access (open access) to its contents. Articles with clinical relevance will be given preference for publication. The Journal publishes original research papers, review articles, rare and novel case reports, and clinical techniques. Manuscripts are invited from all specialties of dentistry i.e., conservative dentistry and endodontics, dentofacial orthopedics and orthodontics, oral medicine and radiology, oral pathology, oral surgery, orodental diseases, pediatric dentistry, implantology, periodontics, clinical aspects of public health dentistry, and prosthodontics.
期刊最新文献
Bibliometric Analysis of Botulinum Toxin and Bruxism: Impact, Visualization, and Collaborative Networks. Comparative Evaluation of Antimicrobial Efficacy of Silver Nanoparticles Infused with Azadirachta indica Extract and Chlorhexidine Against Red-complex Pathogens. Comparative Evaluation of Platelet-rich Fibrin and Treated Dentin Matrix in Regenerative Endodontic Treatment of Nonvital Immature Permanent Teeth: A Randomized Clinical Trial. Comparison of Direct Intraoral Scan and Traditional Impression for CAD/CAM Mandibular Overdenture Base: RCT on Peri-implant Marginal Bone Changes. Comparison of Khoury's Bone Shell Technique vs Titanium-reinforced Polytetrafluoroethylene Membrane for 3D-bone Augmentation in Atrophic Posterior Mandible: A Randomized Clinical Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1