Comparison report of the ITS-90 realization at the freezing point of silver between NIM and CMS

IF 2.1 3区 工程技术 Q2 INSTRUMENTS & INSTRUMENTATION Metrologia Pub Date : 2024-01-01 DOI:10.1088/0026-1394/61/1a/03001
Jianping Sun, Shu-Fei Tsai, Ting Li
{"title":"Comparison report of the ITS-90 realization at the freezing point of silver between NIM and CMS","authors":"Jianping Sun, Shu-Fei Tsai, Ting Li","doi":"10.1088/0026-1394/61/1a/03001","DOIUrl":null,"url":null,"abstract":"\n The APMP key comparison APMP.T-K4.1 was initiated on the request of the Center for Measurement Standards, Taiwan (CMS) to link their standards to the Consultative Committee for Thermometry (CCT) Key Comparison (KC) and facilitate the CMS CMC submission. National Institute of Metrology, China (NIM) provided the linkage to the CCT-K4 at the temperature of the freezing point of silver. In the APMP.T-K4.1, one high temperature standard platinum resistance thermometer (HTSPRT) was chosen as the transfer instrument and was calibrated at the freezing point of silver. The comparison was carried out in a participant-pilot-participant sequence where NIM served as the pilot. The linkage was based on the temperature of CMS reference Ag fixed point relative to the key comparison reference value (KCRV) of CCT-K4 at the Ag fixed point via the difference in temperature between the NIM reference Ag fixed point and NIM reference Ag fixed point (links to the KCRV of the CCT-K4). The temperature difference between the standards of CMS and the KCRV of the CCT-K4 was within the evaluated comparison uncertainties of the ATPM.T-K4.1. This report provides detailed information on the comparison results, linkage mechanism, and the Degree of Equivalence of the CMS relative to the institutes having participated in the CCT-K4.\n To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.\n The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).","PeriodicalId":18444,"journal":{"name":"Metrologia","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrologia","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/0026-1394/61/1a/03001","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

The APMP key comparison APMP.T-K4.1 was initiated on the request of the Center for Measurement Standards, Taiwan (CMS) to link their standards to the Consultative Committee for Thermometry (CCT) Key Comparison (KC) and facilitate the CMS CMC submission. National Institute of Metrology, China (NIM) provided the linkage to the CCT-K4 at the temperature of the freezing point of silver. In the APMP.T-K4.1, one high temperature standard platinum resistance thermometer (HTSPRT) was chosen as the transfer instrument and was calibrated at the freezing point of silver. The comparison was carried out in a participant-pilot-participant sequence where NIM served as the pilot. The linkage was based on the temperature of CMS reference Ag fixed point relative to the key comparison reference value (KCRV) of CCT-K4 at the Ag fixed point via the difference in temperature between the NIM reference Ag fixed point and NIM reference Ag fixed point (links to the KCRV of the CCT-K4). The temperature difference between the standards of CMS and the KCRV of the CCT-K4 was within the evaluated comparison uncertainties of the ATPM.T-K4.1. This report provides detailed information on the comparison results, linkage mechanism, and the Degree of Equivalence of the CMS relative to the institutes having participated in the CCT-K4. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
NIM 和 CMS 在银凝固点实现 ITS-90 的比较报告
APMP关键比对APMP.T-K4.1是应台湾计量标准中心(CMS)的要求启动的,目的是将其标准与测温咨询委员会(CCT)的关键比对(KC)连接起来,方便CMS提交CMC。中国计量科学研究院(NIM)提供了银凝固点温度与 CCT-K4 的链接。在 APMP.T-K4.1 中,选择了一个高温标准铂电阻温度计 (HTSPRT) 作为转移仪器,并在银的凝固点温度下进行了校准。比较按照参与者--试验者--参与者的顺序进行,其中 NIM 为试验者。通过 NIM 参考银定点和 NIM 参考银定点之间的温差(与 CCT-K4 的 KCRV 相联系),根据 CMS 参考银定点相对于 CCT-K4 在银定点的关键比较参考值 (KCRV) 的温度进行联系。CMS 标准与 CCT-K4 的 KCRV 之间的温度差在 ATPM.T-K4.1 评估的比较不确定度范围内。本报告详细介绍了比对结果、联动机制以及 CMS 与参与 CCT-K4 的机构的等效度。要阅读本文正文,请点击最终报告。请注意,该文本是 BIPM 关键对比数据库 https://www.bipm.org/kcdb/ 附录 B 中的文本。根据 CIPM 互认安排(CIPM MRA)的规定,最终报告已经过同行评审,并获准由 CCT 发布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Metrologia
Metrologia 工程技术-物理:应用
CiteScore
2.80
自引率
25.00%
发文量
137
审稿时长
12 months
期刊介绍: Published 6 times per year, Metrologia covers the fundamentals of measurements, particularly those dealing with the seven base units of the International System of Units (metre, kilogram, second, ampere, kelvin, candela, mole) or proposals to replace them. The journal also publishes papers that contribute to the solution of difficult measurement problems and improve the accuracy of derived units and constants that are of fundamental importance to physics. In addition to regular papers, the journal publishes review articles, issues devoted to single topics of timely interest and occasional conference proceedings. Letters to the Editor and Short Communications (generally three pages or less) are also considered.
期刊最新文献
A robust time scale for space applications using the student’s t-distribution A digital four-arm bridge for the comparison of resistance with capacitance Traceable characterisation of fibre-coupled single-photon detectors An emf-temperature reference function for Pt–20%Rh versus Pt thermocouples in the temperature range of 0 °C to 1100 °C Phase reconstruction by phase shift estimation with reliable parameter minimization
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1