Cost-utility of real-time continuous glucose monitoring versus self-monitoring of blood glucose in people with insulin-treated Type II diabetes in France.
Hamza Alshannaq, Richard F Pollock, Michael Joubert, Waqas Ahmed, Gregory J Norman, Peter M Lynch, Stéphane Roze
{"title":"Cost-utility of real-time continuous glucose monitoring versus self-monitoring of blood glucose in people with insulin-treated Type II diabetes in France.","authors":"Hamza Alshannaq, Richard F Pollock, Michael Joubert, Waqas Ahmed, Gregory J Norman, Peter M Lynch, Stéphane Roze","doi":"10.57264/cer-2023-0174","DOIUrl":null,"url":null,"abstract":"<p><p><b>Aim:</b> Clinical trials and real-world data for Type II diabetes both show that glycated hemoglobin (HbA1c) levels and hypoglycemia occurrence can be reduced by real-time continuous glucose monitoring (rt-CGM) versus self-monitoring of blood glucose (SMBG). The present cost-utility study investigated the long-term health economic outcomes associated with using rt-CGM versus SMBG in people with insulin-treated Type II diabetes in France. <b>Materials & methods:</b> Effectiveness data were obtained from a real-world study, which showed rt-CGM reduced HbA1c by 0.56% (6.1 mmol/mol) versus sustained SMBG. Analyses were conducted using the IQVIA Core Diabetes Model. A French payer perspective was adopted over a lifetime horizon for a cohort aged 64.5 years with baseline HbA1c of 8.3% (67 mmol/mol). A willingness-to-pay threshold of €147,093 was used, and future costs and outcomes were discounted at 4% annually. <b>Results:</b> The analysis projected quality-adjusted life expectancy was 8.50 quality-adjusted life years (QALYs) for rt-CGM versus 8.03 QALYs for SMBG (difference: 0.47 QALYs), while total mean lifetime costs were €93,978 for rt-CGM versus €82,834 for SMBG (difference: €11,144). This yielded an incremental cost-utility ratio (ICUR) of €23,772 per QALY gained for rt-CGM versus SMBG. Results were particularly sensitive to changes in the treatment effect (i.e., change in HbA1c), annual price and quality of life benefit associated with rt-CGM, SMBG frequency, baseline patient age and complication costs. <b>Conclusion:</b> The use of rt-CGM is likely to be cost-effective versus SMBG for people with insulin-treated Type II diabetes in France.</p>","PeriodicalId":15539,"journal":{"name":"Journal of comparative effectiveness research","volume":" ","pages":"e230174"},"PeriodicalIF":1.9000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10945438/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of comparative effectiveness research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.57264/cer-2023-0174","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0
Abstract
Aim: Clinical trials and real-world data for Type II diabetes both show that glycated hemoglobin (HbA1c) levels and hypoglycemia occurrence can be reduced by real-time continuous glucose monitoring (rt-CGM) versus self-monitoring of blood glucose (SMBG). The present cost-utility study investigated the long-term health economic outcomes associated with using rt-CGM versus SMBG in people with insulin-treated Type II diabetes in France. Materials & methods: Effectiveness data were obtained from a real-world study, which showed rt-CGM reduced HbA1c by 0.56% (6.1 mmol/mol) versus sustained SMBG. Analyses were conducted using the IQVIA Core Diabetes Model. A French payer perspective was adopted over a lifetime horizon for a cohort aged 64.5 years with baseline HbA1c of 8.3% (67 mmol/mol). A willingness-to-pay threshold of €147,093 was used, and future costs and outcomes were discounted at 4% annually. Results: The analysis projected quality-adjusted life expectancy was 8.50 quality-adjusted life years (QALYs) for rt-CGM versus 8.03 QALYs for SMBG (difference: 0.47 QALYs), while total mean lifetime costs were €93,978 for rt-CGM versus €82,834 for SMBG (difference: €11,144). This yielded an incremental cost-utility ratio (ICUR) of €23,772 per QALY gained for rt-CGM versus SMBG. Results were particularly sensitive to changes in the treatment effect (i.e., change in HbA1c), annual price and quality of life benefit associated with rt-CGM, SMBG frequency, baseline patient age and complication costs. Conclusion: The use of rt-CGM is likely to be cost-effective versus SMBG for people with insulin-treated Type II diabetes in France.
期刊介绍:
Journal of Comparative Effectiveness Research provides a rapid-publication platform for debate, and for the presentation of new findings and research methodologies.
Through rigorous evaluation and comprehensive coverage, the Journal of Comparative Effectiveness Research provides stakeholders (including patients, clinicians, healthcare purchasers, and health policy makers) with the key data and opinions to make informed and specific decisions on clinical practice.