Wearable near-infrared spectroscopy: reliability and sensitivity among different endurance cycling exercise intensities.

IF 1.9 4区 医学 Q2 BIOLOGY Brazilian Journal of Medical and Biological Research Pub Date : 2024-03-04 eCollection Date: 2024-01-01 DOI:10.1590/1414-431X2024e13102
J S Hasegawa, R A Azevedo, A C Silveira, A E Lima-Silva, R Bertuzzi
{"title":"Wearable near-infrared spectroscopy: reliability and sensitivity among different endurance cycling exercise intensities.","authors":"J S Hasegawa, R A Azevedo, A C Silveira, A E Lima-Silva, R Bertuzzi","doi":"10.1590/1414-431X2024e13102","DOIUrl":null,"url":null,"abstract":"<p><p>The present study investigated the reliability and sensitivity of a wearable near-infrared spectroscopy (wNIRS) device in moderate and heavy exercise intensity domains. On three separate days, eleven males performed an incremental test to exhaustion, and in the following visits, four submaximal constant-load bouts (i.e., test and retest) were performed in the moderate-intensity domain (100 and 130 W) and heavy-intensity domain (160 and 190 W). The local tissue oxygen saturation index (SmO2) and pulmonary oxygen uptake (V̇O2) were measured continuously. The absolute SmO2 and V̇O2 values and the change (Δ) from the 3rd to 6th min of exercise were calculated. There was good reliability for SmO2 measurements, as indicated by the high intraclass correlation coefficient analysis (ICC ≥0.84 for all) and low coefficient of variation between the two trials (CV ≤4.1% for all). Steady-state responses were observed for SmO2 and V̇O2 from the 3rd to the 6th min in the two moderate-intensity bouts (P>0.05), whereas SmO2 decreased and V̇O2 increased from the 3rd to the 6th min in the two heavy-intensity bouts (P<0.05). Together, these findings suggested that the SmO2 measured with a wNIRS device is reliable and sensitive to track local metabolic changes provoked by slight increments in exercise intensity.</p>","PeriodicalId":9088,"journal":{"name":"Brazilian Journal of Medical and Biological Research","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10913389/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Medical and Biological Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1414-431X2024e13102","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The present study investigated the reliability and sensitivity of a wearable near-infrared spectroscopy (wNIRS) device in moderate and heavy exercise intensity domains. On three separate days, eleven males performed an incremental test to exhaustion, and in the following visits, four submaximal constant-load bouts (i.e., test and retest) were performed in the moderate-intensity domain (100 and 130 W) and heavy-intensity domain (160 and 190 W). The local tissue oxygen saturation index (SmO2) and pulmonary oxygen uptake (V̇O2) were measured continuously. The absolute SmO2 and V̇O2 values and the change (Δ) from the 3rd to 6th min of exercise were calculated. There was good reliability for SmO2 measurements, as indicated by the high intraclass correlation coefficient analysis (ICC ≥0.84 for all) and low coefficient of variation between the two trials (CV ≤4.1% for all). Steady-state responses were observed for SmO2 and V̇O2 from the 3rd to the 6th min in the two moderate-intensity bouts (P>0.05), whereas SmO2 decreased and V̇O2 increased from the 3rd to the 6th min in the two heavy-intensity bouts (P<0.05). Together, these findings suggested that the SmO2 measured with a wNIRS device is reliable and sensitive to track local metabolic changes provoked by slight increments in exercise intensity.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
可穿戴式近红外光谱仪:不同耐力自行车运动强度下的可靠性和灵敏度。
本研究调查了可穿戴式近红外光谱仪(wNIRS)在中度和重度运动强度领域的可靠性和灵敏度。在三个不同的日子里,11 名男性分别进行了增量测试直至力竭,并在接下来的访问中,分别在中等强度域(100 和 130 W)和大强度域(160 和 190 W)进行了四次次最大恒定负荷测试(即测试和复测)。连续测量局部组织氧饱和度指数(SmO2)和肺摄氧量(V̇O2)。计算了 SmO2 和 V̇O2 的绝对值以及从运动第 3 分钟到第 6 分钟的变化 (Δ)。SmO2 测量值的可靠性很高,这体现在高类内相关系数分析(ICC 均≥0.84)和两次试验之间的低变异系数(CV 均≤4.1%)。在两次中等强度的比赛中,从第 3 分钟到第 6 分钟,SmO2 和 V̇O2 都出现了稳态反应(P>0.05),而在两次高强度的比赛中,从第 3 分钟到第 6 分钟,SmO2 下降,V......O2 上升(P>0.05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.00
自引率
0.00%
发文量
129
审稿时长
2 months
期刊介绍: The Brazilian Journal of Medical and Biological Research, founded by Michel Jamra, is edited and published monthly by the Associação Brasileira de Divulgação Científica (ABDC), a federation of Brazilian scientific societies: - Sociedade Brasileira de Biofísica (SBBf) - Sociedade Brasileira de Farmacologia e Terapêutica Experimental (SBFTE) - Sociedade Brasileira de Fisiologia (SBFis) - Sociedade Brasileira de Imunologia (SBI) - Sociedade Brasileira de Investigação Clínica (SBIC) - Sociedade Brasileira de Neurociências e Comportamento (SBNeC).
期刊最新文献
Cognitive behavioral stress management effectively facilitates neurologic recovery, alleviates mental distress, and elevates health status in acute ischemic stroke patients. Decoding potential targets and pharmacologic mechanisms of curcumin in treating non-small cell lung carcinoma via bioinformatics and molecular docking. Diagnostic value of serum inflammatory markers in predicting early refractoriness of transarterial chemoembolization in patients with Barcelona Clinic Liver Cancer Stage 0, A, and B hepatocellular carcinoma. Inhibition of the ITGB1 gene attenuates crystalline silica-induced pulmonary fibrosis via epithelial-mesenchymal transformation. NLRP1 inhibits lung adenocarcinoma growth through mediating mitochondrial dysregulation in an inflammasome-independent manner.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1