The impact of barrier arrangements on the transmission of respiratory infectious diseases in nursing homes in Hong Kong

IF 3.2 3区 工程技术 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Indoor and Built Environment Pub Date : 2024-03-07 DOI:10.1177/1420326x241236970
Yiqi Tao, Folong Zhong, Yijia Miao, Haida Tang, Lingling Li
{"title":"The impact of barrier arrangements on the transmission of respiratory infectious diseases in nursing homes in Hong Kong","authors":"Yiqi Tao, Folong Zhong, Yijia Miao, Haida Tang, Lingling Li","doi":"10.1177/1420326x241236970","DOIUrl":null,"url":null,"abstract":"Respiratory infectious diseases have affected the health of the elderly. This study investigated the optimization of physical barriers as a low-cost design strategy to reduce the risk of infection in nursing homes for the elderly in Hong Kong, which were significantly affected by the outbreak of COVID-19. First, data on two types of rooms, single and multi-occupancy, were collected from a field investigation of typical local nursing homes. Subsequently, Computational Fluid Dynamics (CFD) simulations were employed to analyse the effects of various barrier heights on the propagation, suspension, deposition and elimination of aerosol particles in these room types, thereby evaluating infection risks. The findings reveal that in single-occupancy rooms, a barrier height of 2.1 m is effective in curtailing the spread of the virus over distances. Conversely, in multi-occupancy rooms, while a 1.8-m barrier is necessary, the rate of particle suspension is considerably higher, necessitating additional ventilation measures. Based on these findings, the study provides quantitative criteria for the implementation of physical barriers as a low-cost physical measure in nursing homes and provides recommendations for the effective prevention of respiratory infectious diseases through design modifications.","PeriodicalId":13578,"journal":{"name":"Indoor and Built Environment","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indoor and Built Environment","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/1420326x241236970","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Respiratory infectious diseases have affected the health of the elderly. This study investigated the optimization of physical barriers as a low-cost design strategy to reduce the risk of infection in nursing homes for the elderly in Hong Kong, which were significantly affected by the outbreak of COVID-19. First, data on two types of rooms, single and multi-occupancy, were collected from a field investigation of typical local nursing homes. Subsequently, Computational Fluid Dynamics (CFD) simulations were employed to analyse the effects of various barrier heights on the propagation, suspension, deposition and elimination of aerosol particles in these room types, thereby evaluating infection risks. The findings reveal that in single-occupancy rooms, a barrier height of 2.1 m is effective in curtailing the spread of the virus over distances. Conversely, in multi-occupancy rooms, while a 1.8-m barrier is necessary, the rate of particle suspension is considerably higher, necessitating additional ventilation measures. Based on these findings, the study provides quantitative criteria for the implementation of physical barriers as a low-cost physical measure in nursing homes and provides recommendations for the effective prevention of respiratory infectious diseases through design modifications.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
屏障安排对香港疗养院呼吸道传染病传播的影响
呼吸道传染病影响着老年人的健康。本研究探讨了如何优化物理屏障,将其作为一种低成本的设计策略,以降低受 COVID-19 爆发严重影响的香港养老院的感染风险。首先,通过对本地典型疗养院的实地调查,收集了单人和多人两种类型房间的数据。随后,研究人员利用计算流体动力学(CFD)模拟分析了不同阻隔高度对气溶胶粒子在这些房间内的传播、悬浮、沉积和消除的影响,从而评估了感染风险。研究结果表明,在单人房间中,2.1 米的屏障高度可有效遏制病毒的远距离传播。相反,在多人房间中,虽然需要 1.8 米的屏障,但微粒的悬浮率要高得多,因此有必要采取额外的通风措施。基于这些发现,该研究为在养老院实施物理屏障这一低成本物理措施提供了量化标准,并为通过修改设计有效预防呼吸道传染病提供了建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Indoor and Built Environment
Indoor and Built Environment 环境科学-工程:环境
CiteScore
6.40
自引率
25.00%
发文量
130
审稿时长
2.6 months
期刊介绍: Indoor and Built Environment publishes reports on any topic pertaining to the quality of the indoor and built environment, and how these might effect the health, performance, efficiency and comfort of persons living or working there. Topics range from urban infrastructure, design of buildings, and materials used to laboratory studies including building airflow simulations and health effects. This journal is a member of the Committee on Publication Ethics (COPE).
期刊最新文献
Dynamics of indoor volatile organic compounds and seasonal ventilation strategies for residential buildings in Northeast China The indoor thermal environment performance of various air-conditioning system configurations and airflow modes in a large space museum building Leakage identification and correlation coefficient method for industrial workshop production process combining with computational fluid dynamics Synthesis and performance study of biomass-based suppressant and its application in radioactive aerosol sedimentation Modelling of radiation and flow fields in in-duct ultraviolet germicidal irradiation systems with and without ribs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1