Evaluation of Short-Term Use of Positive and Oscillating Positive Expiratory Pressure in Bronchial Drainage in Cystic Fibrosis Patients During an Exacerbation of The Disease

Q4 Medicine Rehabilitacja Medyczna Pub Date : 2024-02-16 DOI:10.5604/01.3001.0054.3480
J. Prusak, K. Warzeszak, P. Kurzeja
{"title":"Evaluation of Short-Term Use of Positive and Oscillating Positive Expiratory Pressure in Bronchial Drainage in Cystic Fibrosis Patients During an Exacerbation of The Disease","authors":"J. Prusak, K. Warzeszak, P. Kurzeja","doi":"10.5604/01.3001.0054.3480","DOIUrl":null,"url":null,"abstract":"Introduction: Cystic fibrosis is the most common severe autosomal recessive genetic disease in Caucasians. The main disorder in the course of cystic fibrosis is the accumulation of a large amount of thick and viscous secretion in the bronchi.Objectives: To assess the efficacy of the usage of selected devices generating positive expiratory pressure (PEP S System device) and oscillating positive expiratory pressure (OPEP Aerobika, Flutter devices) in bronchial drainage in cystic fibrosis patients during exacerbation of the disease.Methods: The study involved 35 cystic fibrosis patients with an average age of 23.38.5 yrs. In the study group, a 4-day bronchial drainage cycle was used.Results: The FEV1 indicator for the whole group was 55.623% of the predicted value, and the size of the improvement, similarly to FVC and MEF25, was statistically significant (p<0.001). The mean value of the expectorated secretion in the bronchial drainage program was 88.175.3 ml in the OPEP Aerobika group, 80.589 ml in the OPEP Flutter group and 63.8105 ml in the PEP group. There were no differences between groups also in the value of collected secretion and in improvement of the lung function.Conclusions: The results of the study indicate the approximate effectiveness of the devices and methods of bronchial drainage used in patients with cystic fibrosis in exacerbation of the disease.","PeriodicalId":35329,"journal":{"name":"Rehabilitacja Medyczna","volume":"226 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rehabilitacja Medyczna","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0054.3480","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Cystic fibrosis is the most common severe autosomal recessive genetic disease in Caucasians. The main disorder in the course of cystic fibrosis is the accumulation of a large amount of thick and viscous secretion in the bronchi.Objectives: To assess the efficacy of the usage of selected devices generating positive expiratory pressure (PEP S System device) and oscillating positive expiratory pressure (OPEP Aerobika, Flutter devices) in bronchial drainage in cystic fibrosis patients during exacerbation of the disease.Methods: The study involved 35 cystic fibrosis patients with an average age of 23.38.5 yrs. In the study group, a 4-day bronchial drainage cycle was used.Results: The FEV1 indicator for the whole group was 55.623% of the predicted value, and the size of the improvement, similarly to FVC and MEF25, was statistically significant (p<0.001). The mean value of the expectorated secretion in the bronchial drainage program was 88.175.3 ml in the OPEP Aerobika group, 80.589 ml in the OPEP Flutter group and 63.8105 ml in the PEP group. There were no differences between groups also in the value of collected secretion and in improvement of the lung function.Conclusions: The results of the study indicate the approximate effectiveness of the devices and methods of bronchial drainage used in patients with cystic fibrosis in exacerbation of the disease.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
对囊性纤维化患者在疾病恶化期间短期使用正压和振荡呼气正压进行支气管引流的评估
导言:囊性纤维化是白种人中最常见的严重常染色体隐性遗传病。囊性纤维化病程中的主要障碍是支气管内积聚大量粘稠分泌物:目的:评估在囊性纤维化患者病情加重期间使用选定的呼气正压装置(PEP S 系统装置)和振荡呼气正压装置(OPEP Aerobika、Flutter 装置)进行支气管引流的疗效:研究组采用 4 天支气管引流周期:全组患者的 FEV1 指标为预测值的 55.623%,改善幅度与 FVC 和 MEF25 相似,具有显著的统计学意义(P<0.001)。在支气管引流程序中,OPEP Aerobika 组的祛痰分泌物平均值为 88.175.3 毫升,OPEP Flutter 组为 80.589 毫升,PEP 组为 63.8105 毫升。各组在收集分泌物的数值和改善肺功能方面也没有差异:研究结果表明,囊性纤维化患者在病情加重时使用的支气管引流设备和方法大致有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Rehabilitacja Medyczna
Rehabilitacja Medyczna Medicine-Rehabilitation
CiteScore
0.30
自引率
0.00%
发文量
26
审稿时长
19 weeks
期刊最新文献
Rheological Properties of Blood in Patients with Diabetic Foot Ulcers Treated with Local Hyperbaric Oxygen Therapy - Preliminary Report Functional Patterns and Postural Balance in Young Women With Chronic Non-Specific Low Back Pain and Healthy Individuals Comparing Influence of Thermal Effects in Experimental Models - Thermotherapy in Medical Rehabilitation Development and Reliability of Parents' Body Posture Literacy Questionnaire (PBPLQ) Effect of Selected Kinesiology Taping Applications on Reducing Pain and Accelerating Rehabilitation in Children with Osgood-Schlatter Disease
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1