Follow-up evaluation of snuffbox arteriovenous fistula as an alternative site for hemodialysis - a case series in a lower-middle country

IF 0.9 Q3 MEDICINE, GENERAL & INTERNAL Bali Medical Journal Pub Date : 2024-02-16 DOI:10.15562/bmj.v13i1.5161
Yunanto Kurnia, Trianingsih Trianingsih, Tandean Tommy Novenanto, S. Supomo, Haryo Aribowo, Yuletta Adny Ambarsari, Ihsanul Amal
{"title":"Follow-up evaluation of snuffbox arteriovenous fistula as an alternative site for hemodialysis - a case series in a lower-middle country","authors":"Yunanto Kurnia, Trianingsih Trianingsih, Tandean Tommy Novenanto, S. Supomo, Haryo Aribowo, Yuletta Adny Ambarsari, Ihsanul Amal","doi":"10.15562/bmj.v13i1.5161","DOIUrl":null,"url":null,"abstract":"Link of Video Abstract: https://youtu.be/MSeO8kuKhGc\n \nIntroduction: The preferred vascular access for hemodialysis in chronic kidney disease patients is the arteriovenous fistula (AVF). It is recommended to create AVFs as distally as possible. The snuffbox, situated at the far end of the wrist, is infrequently utilized for AVF insertion due to the prevalent smaller vessel calibers.\n Case: This case series involves seven patients with chronic kidney disease scheduled for first AVF placement in the snuffbox region, with an average age of 56.71 years.  All patients showed an average radial artery caliber of 20.3mm, a mean peak systolic velocity of 67.14 cm/s, and a cephalic vein caliber of 22.7mm, according to preoperative vascular ultrasound. The AVF placement involved an end-to-side anastomosis. All patient demonstrated anastomosis clinical maturation, the primary patency rate was 86%. Follow-up Doppler examinations revealed that patients achieving functional patency had an average caliber of 5.22mm and an average flow rate of 810.65 ml/s.\n Conclusion: SAVF are created less frequently due to predominantly smaller vessel caliber. However, it can be a viable alternative site for fistula implantation. Vascular mapping is required to ensure that both vessels have minimum 2 mm caliber. Maturation in SAVF have comparable results with the other sites.","PeriodicalId":44369,"journal":{"name":"Bali Medical Journal","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-02-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bali Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15562/bmj.v13i1.5161","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Link of Video Abstract: https://youtu.be/MSeO8kuKhGc   Introduction: The preferred vascular access for hemodialysis in chronic kidney disease patients is the arteriovenous fistula (AVF). It is recommended to create AVFs as distally as possible. The snuffbox, situated at the far end of the wrist, is infrequently utilized for AVF insertion due to the prevalent smaller vessel calibers.  Case: This case series involves seven patients with chronic kidney disease scheduled for first AVF placement in the snuffbox region, with an average age of 56.71 years.  All patients showed an average radial artery caliber of 20.3mm, a mean peak systolic velocity of 67.14 cm/s, and a cephalic vein caliber of 22.7mm, according to preoperative vascular ultrasound. The AVF placement involved an end-to-side anastomosis. All patient demonstrated anastomosis clinical maturation, the primary patency rate was 86%. Follow-up Doppler examinations revealed that patients achieving functional patency had an average caliber of 5.22mm and an average flow rate of 810.65 ml/s.  Conclusion: SAVF are created less frequently due to predominantly smaller vessel caliber. However, it can be a viable alternative site for fistula implantation. Vascular mapping is required to ensure that both vessels have minimum 2 mm caliber. Maturation in SAVF have comparable results with the other sites.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
鼻腔动静脉瘘作为血液透析替代部位的随访评估--一个中下等国家的系列病例
视频摘要链接:https://youtu.be/MSeO8kuKhGc 简介:慢性肾病患者血液透析的首选血管通路是动静脉内瘘 (AVF)。建议尽可能在远端建立 AVF。由于血管口径普遍较小,位于手腕远端的鼻咽部很少用于插入 AVF。病例:本病例系列涉及七名慢性肾病患者,他们计划在鼻烟盒区域进行首次 AVF 置入手术,平均年龄为 56.71 岁。 术前血管超声检查显示,所有患者的桡动脉平均口径为 20.3 毫米,平均收缩峰值速度为 67.14 厘米/秒,头静脉口径为 22.7 毫米。动静脉瓣膜置入术采用端侧吻合。所有患者的吻合术均已临床成熟,初次通畅率为 86%。随访多普勒检查显示,获得功能性通畅的患者平均口径为 5.22 毫米,平均流速为 810.65 毫升/秒。结论:SAVF 由于血管口径较小而较少使用。然而,它可以作为瘘管植入的可行替代部位。需要进行血管测绘,以确保两根血管的口径都至少为 2 毫米。SAVF的成熟效果与其他部位相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Bali Medical Journal
Bali Medical Journal MEDICINE, GENERAL & INTERNAL-
自引率
50.00%
发文量
8
审稿时长
3 weeks
期刊最新文献
The effect of fractionated ethanol red ginger (Zingiber officinale var. rubrum) extract on the pH level of Streptococcus gordonii metabolism (In-vitro Laboratory Experimental Research) Efficacy of combination therapy 5% permethrin cream and precipitated sulfur (ointment 2-4) compared with single therapy of 5% permethrin cream in children Hemangioma activity score evaluation in infantile hemangioma patients: a retrospective study Effect of Paraquat toxicity on lung and kidney organs on histopathological image assessment Mortality comparison between axillary lymph node dissection (ALND) and sentinel lymph node biopsy (SND) among breast cancer pantient: A meta-analysis and systematic review study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1