Higher contact pressure of the lateral tibiofemoral joint in lateral extra-articular tenodesis with tensioned graft in external rotation than in neutral rotation: A biomechanical study

{"title":"Higher contact pressure of the lateral tibiofemoral joint in lateral extra-articular tenodesis with tensioned graft in external rotation than in neutral rotation: A biomechanical study","authors":"","doi":"10.1016/j.jisako.2024.04.009","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>To determine the mean contact pressure, peak contact pressure, and mean contact area of the lateral tibiofemoral joint in lateral extra-articular tenodesis (LET) with tension on the graft in tibial neutral and external rotation.</p></div><div><h3>Methods</h3><p>A total of eight Thiel-embalmed cadaveric knees were prepared and divided into two groups (4 knees in each group): the LET-NR group (lateral extra-articular tenodesis tension in neutral rotation) and (2) the LET-ER group (lateral extra-articular tenodesis tension in external rotation). Each knee was prepared according to the corresponding technique. A hydraulic testing system (E10000, Instron) simulates an axial load of 735 ​N for 10 ​s in each group.</p></div><div><h3>Results</h3><p>The LET-ER group exhibited a statistically significant higher peak contact pressure compared to the LET-NR group. The peak contact pressure values in the LET-NR and LET-ER groups were 702.3 ​± ​233.9 ​kPa and 1235.5 ​± ​171.4 ​kPa, respectively (<em>p</em> ​= ​0.010, 95% CI, −888.0 to −178.5). The mean contact pressure values in the LET-NR and LET-ER groups were 344.9 ​± ​69.0 ​kPa and 355.3 ​± ​34.9 ​kPa, respectively (<em>p</em> ​= ​0.796, 95% CI, −105.1–84.2). The mean contact area values in the LET-NR and LET-ER groups were 36.8 ​± ​3.1 mm<sup>2</sup> and 33.3 ​± ​6.4 mm<sup>2</sup>, respectively (<em>p</em> ​= ​0.360, 95% CI, −5.2–12.2).</p></div><div><h3>Conclusions</h3><p>The peak contact pressure of the lateral tibiofemoral joint is greater in LET when the graft is tensioned in external rotation than in neutral rotation. However, no statistically significant difference in the mean contact pressure or the mean contact area was observed between the two groups.</p></div><div><h3>Level of evidence</h3><p>III.</p></div>","PeriodicalId":36847,"journal":{"name":"Journal of ISAKOS Joint Disorders & Orthopaedic Sports Medicine","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2059775424000798/pdfft?md5=30167f1ce3b2f59f86238dcd872bcb6f&pid=1-s2.0-S2059775424000798-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of ISAKOS Joint Disorders & Orthopaedic Sports Medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2059775424000798","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

To determine the mean contact pressure, peak contact pressure, and mean contact area of the lateral tibiofemoral joint in lateral extra-articular tenodesis (LET) with tension on the graft in tibial neutral and external rotation.

Methods

A total of eight Thiel-embalmed cadaveric knees were prepared and divided into two groups (4 knees in each group): the LET-NR group (lateral extra-articular tenodesis tension in neutral rotation) and (2) the LET-ER group (lateral extra-articular tenodesis tension in external rotation). Each knee was prepared according to the corresponding technique. A hydraulic testing system (E10000, Instron) simulates an axial load of 735 ​N for 10 ​s in each group.

Results

The LET-ER group exhibited a statistically significant higher peak contact pressure compared to the LET-NR group. The peak contact pressure values in the LET-NR and LET-ER groups were 702.3 ​± ​233.9 ​kPa and 1235.5 ​± ​171.4 ​kPa, respectively (p ​= ​0.010, 95% CI, −888.0 to −178.5). The mean contact pressure values in the LET-NR and LET-ER groups were 344.9 ​± ​69.0 ​kPa and 355.3 ​± ​34.9 ​kPa, respectively (p ​= ​0.796, 95% CI, −105.1–84.2). The mean contact area values in the LET-NR and LET-ER groups were 36.8 ​± ​3.1 mm2 and 33.3 ​± ​6.4 mm2, respectively (p ​= ​0.360, 95% CI, −5.2–12.2).

Conclusions

The peak contact pressure of the lateral tibiofemoral joint is greater in LET when the graft is tensioned in external rotation than in neutral rotation. However, no statistically significant difference in the mean contact pressure or the mean contact area was observed between the two groups.

Level of evidence

III.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
与中性旋转相比,外旋时使用张力移植的外侧关节外侧腱膜挛缩术对胫股关节的接触压力更大:一项生物力学研究。
目的确定在胫骨中立和外旋状态下进行外侧关节外侧腱膜挛缩术(LET)并对移植物施加张力时,胫股关节外侧的平均接触压力、峰值接触压力和平均接触面积:共准备了 8 个蒂尔氏防腐尸体膝关节,并将其分为两组(每组 4 个膝关节):LET-NR 组(中立旋转时的外侧关节外侧腱膜挛缩张力)和 (2) LET-ER 组(外侧关节外侧腱膜挛缩张力)。每个膝关节都按照相应的技术进行了准备。液压测试系统(E10000,Instron)模拟每组 10 秒钟 735 牛的轴向负荷:结果:与 LET-NR 组相比,LET-ER 组的峰值接触压力明显高于 LET-NR 组。LET-NR 组和 LET-ER 组的接触压力峰值分别为 702.3 ± 233.9 kPa 和 1,235.5 ± 171.4 kPa(p = 0.010,95% CI,-888.0--178.5)。LET-NR 组和 LET-ER 组的平均接触压力值分别为 344.9 ± 69.0 kPa 和 355.3 ± 34.9 kPa(p = 0.796,95% CI,-105.1-84.2)。LET-NR 组和 LET-ER 组的平均接触面积值分别为 36.8 ± 3.1 mm2 和 33.3 ± 6.4 mm2(p = 0.360,95% CI,-5.2-12.2):在LET中,移植物外旋时的峰值接触压力大于中性旋转时的峰值接触压力。然而,两组之间的平均接触压力或平均接触面积没有统计学意义上的显著差异:证据等级:III.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.90
自引率
6.20%
发文量
61
审稿时长
108 days
期刊最新文献
Clinical Outcomes of Arthroscopic Surgical Intervention in Femoroacetabular Impingement Amongst the Asian Population: A Meta-analysis. Ligamentous Ankle Injuries in Relation to the Morphology of the Incisura Fibularis: A Systematic Review. Acute compartment syndrome of the leg following peroneus longus tendon graft harvesting: case report. MCL pie crusting for concomitant medial meniscal surgery does not appear to adversely influence primary ACL reconstruction functional outcomes. Oblique or short incisions reduce the risk of saphenous nerve damage during hamstrings harvesting. A model for mapping nerve pathways at the harvest site.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1