Introduction of ex vivo perfusion of extended-criteria donor hearts in a single center in Asia.

IF 1.1 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Artificial Organs Pub Date : 2024-05-23 DOI:10.1007/s10047-024-01447-x
Oswald Joseph On Jing Lee, Inderjeet Bhatia, Sylvia Ho Yan Wan, Katherine Yue Yan Fan, Michael Ka Lam Wong, Timmy Wing Kuk Au, Cally Ka Lai Ho
{"title":"Introduction of ex vivo perfusion of extended-criteria donor hearts in a single center in Asia.","authors":"Oswald Joseph On Jing Lee, Inderjeet Bhatia, Sylvia Ho Yan Wan, Katherine Yue Yan Fan, Michael Ka Lam Wong, Timmy Wing Kuk Au, Cally Ka Lai Ho","doi":"10.1007/s10047-024-01447-x","DOIUrl":null,"url":null,"abstract":"<p><p>The shortage of organs for heart transplantation has created a need to explore the use of extended-criteria organs. We report the preliminary use of normothermic TransMedics Organ Care System-an ex vivo approach to preserve extended-criteria brain-dead donor hearts. This System maintains a normal temperature, provides continuous perfusion and oxygenation, reduces ischemic time, and enables additional viability assessment options. In a retrospective single-centre study conducted from April 2020 to March 2023, four extended criteria brain-dead donor hearts were perfused and monitored using the Organ Care System. Suitability for transplantation was assessed based on stable or decreasing lactate levels, along with appropriate perfusion parameters. The Organ Care for use of the Organ Care System were coronary artery disease, left ventricular hypertrophy, high-dose inotrope use in the donor, a downtime exceeding 20 min, and a left ventricular ejection fraction of 40-50%. Three out of the four donor hearts were transplanted, while one was discarded due to rising lactate concentration. The three recipients had a higher surgical risk profile for heart transplant. All showed normal cardiac function and no primary graft dysfunction postoperatively. At 2-3 years post-transplant, all recipients have a ventricular function of > 60%, with only one showing evidence of mild rejection. The Organ Care System enables the successful transplantation of marginal donor organs in high-risk recipients, showcasing the feasibility of recruiting donors with extended criteria. This technique is safe and promising, expanding the donor pool and addressing the organ shortage in heart transplantation in Hong Kong.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-024-01447-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The shortage of organs for heart transplantation has created a need to explore the use of extended-criteria organs. We report the preliminary use of normothermic TransMedics Organ Care System-an ex vivo approach to preserve extended-criteria brain-dead donor hearts. This System maintains a normal temperature, provides continuous perfusion and oxygenation, reduces ischemic time, and enables additional viability assessment options. In a retrospective single-centre study conducted from April 2020 to March 2023, four extended criteria brain-dead donor hearts were perfused and monitored using the Organ Care System. Suitability for transplantation was assessed based on stable or decreasing lactate levels, along with appropriate perfusion parameters. The Organ Care for use of the Organ Care System were coronary artery disease, left ventricular hypertrophy, high-dose inotrope use in the donor, a downtime exceeding 20 min, and a left ventricular ejection fraction of 40-50%. Three out of the four donor hearts were transplanted, while one was discarded due to rising lactate concentration. The three recipients had a higher surgical risk profile for heart transplant. All showed normal cardiac function and no primary graft dysfunction postoperatively. At 2-3 years post-transplant, all recipients have a ventricular function of > 60%, with only one showing evidence of mild rejection. The Organ Care System enables the successful transplantation of marginal donor organs in high-risk recipients, showcasing the feasibility of recruiting donors with extended criteria. This technique is safe and promising, expanding the donor pool and addressing the organ shortage in heart transplantation in Hong Kong.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在亚洲的一个中心引入扩展标准供体心脏体外灌注。
由于用于心脏移植的器官短缺,因此需要探索如何使用扩展标准器官。我们报告了常温 TransMedics 器官护理系统的初步使用情况--这是一种保存扩展标准脑死亡捐献者心脏的体外方法。该系统可保持正常温度,提供持续灌注和供氧,缩短缺血时间,并提供更多存活率评估选项。在 2020 年 4 月至 2023 年 3 月进行的一项回顾性单中心研究中,使用器官护理系统对四例扩展标准脑死亡供体心脏进行了灌注和监测。根据稳定或下降的乳酸水平以及适当的灌注参数评估是否适合移植。使用器官护理系统的器官护理指标包括:冠状动脉疾病、左心室肥厚、供体使用大剂量肌力药物、停机时间超过20分钟以及左心室射血分数为40-50%。四颗供体心脏中有三颗被移植,一颗因乳酸浓度升高而被放弃。三名受者的心脏移植手术风险较高。所有受者术后心脏功能正常,没有出现原发性移植功能障碍。移植后 2-3 年,所有受者的心室功能均大于 60%,只有一人出现轻度排斥反应。器官护理系统使边缘捐献者的器官成功移植给高风险受者,展示了根据扩展标准招募捐献者的可行性。这项技术安全可靠,可扩大器官捐献者库,解决香港心脏移植器官短缺的问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Artificial Organs
Journal of Artificial Organs 医学-工程:生物医学
CiteScore
2.80
自引率
15.40%
发文量
68
审稿时长
6-12 weeks
期刊介绍: The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.
期刊最新文献
Exploring the role of plasmapheresis prior to thyroidectomy in managing thyrotoxicosis: a comprehensive scoping review. A compact machine perfusion device for whole blood perfusion in isolated rat liver. Advanced roll porous scaffold 3D bioprinting technology. Impact of the spleen size on short-term prognosis in patients with cardiogenic shock receiving Impella-incorporated temporary mechanical circulatory support Axial-flow polymer bridge pump with hydrodynamic bearings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1