{"title":"Field-Circuit Combination Method for Solving the Detuning Problem of Magnetic Resonance Human Body Communication","authors":"Lixuan Huang;Ziliang Wei;Bingheng Chen;Sio Hang Pun;Mang I Vai;Yueming Gao","doi":"10.1109/JERM.2024.3367247","DOIUrl":null,"url":null,"abstract":"The technological challenge to realize wearable medical devices is to ensure low power consumption and reliable transmission of communication. Magnetic resonance human body communication (MR HBC) provides ideas to improve the transmission effect. Although the coil's resonance properties have been proposed for MR HBC, the modeling and impedance matching for this method are still in the exploratory stage. However, different human impedances affect the coil resonance frequency to varying extents, leading to individual variability in the degree of magnetic coupling. This paper analyzes the influence of human tissues on the coil through finite element method (FEM) simulation modeling. This effect can be eliminated by employing a dual tunable capacitor matching method based on the field-circuit combination. By dynamically adjusting the values of the dual tunable capacitors in real-time, the human body and the coil can be tuned to a resonant state, effectively improving the degree of magnetic coupling. The results reveal that the proposed method enhances the communication gain by 38.91–42.02 dB at the preset frequency for different human tissues. In vivo experiments verify that the method eliminates the effect of different human impedances on the coil, which is of great significance for further improving the performance of MR HBC.","PeriodicalId":29955,"journal":{"name":"IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology","volume":"8 2","pages":"94-101"},"PeriodicalIF":3.0000,"publicationDate":"2024-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10449336/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The technological challenge to realize wearable medical devices is to ensure low power consumption and reliable transmission of communication. Magnetic resonance human body communication (MR HBC) provides ideas to improve the transmission effect. Although the coil's resonance properties have been proposed for MR HBC, the modeling and impedance matching for this method are still in the exploratory stage. However, different human impedances affect the coil resonance frequency to varying extents, leading to individual variability in the degree of magnetic coupling. This paper analyzes the influence of human tissues on the coil through finite element method (FEM) simulation modeling. This effect can be eliminated by employing a dual tunable capacitor matching method based on the field-circuit combination. By dynamically adjusting the values of the dual tunable capacitors in real-time, the human body and the coil can be tuned to a resonant state, effectively improving the degree of magnetic coupling. The results reveal that the proposed method enhances the communication gain by 38.91–42.02 dB at the preset frequency for different human tissues. In vivo experiments verify that the method eliminates the effect of different human impedances on the coil, which is of great significance for further improving the performance of MR HBC.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
解决磁共振人体通信失谐问题的场-电路组合方法
实现可穿戴医疗设备的技术挑战在于确保低功耗和可靠的通信传输。磁共振人体通信(MR HBC)为改善传输效果提供了思路。虽然已经提出了磁共振人体通信的线圈共振特性,但该方法的建模和阻抗匹配仍处于探索阶段。然而,不同人体阻抗对线圈共振频率的影响程度不同,从而导致磁耦合程度的个体差异性。本文通过有限元法(FEM)模拟建模分析了人体组织对线圈的影响。通过采用基于场-电路组合的双可调电容器匹配方法,可以消除这种影响。通过实时动态调整双可调电容器的值,可将人体和线圈调谐到共振状态,从而有效改善磁耦合度。研究结果表明,在不同人体组织的预设频率下,该方法可将通信增益提高 38.91-42.02 dB。体内实验验证了该方法消除了不同人体阻抗对线圈的影响,这对进一步提高磁共振 HBC 的性能具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.80
自引率
9.40%
发文量
58
期刊最新文献
Front Cover Table of Contents IEEE Journal of Electromagnetics, RF, and Microwaves in Medicine and Biology About this Journal IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology Publication Information Front Cover
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1