Carlotta Lauteri, L. Pennisi, Daniele Di Clerico, Viola Pennisi, Alberto Vergara
{"title":"Low-frequency focused thermosonication for Salmonella typhimurium inactivation: an in vitro study","authors":"Carlotta Lauteri, L. Pennisi, Daniele Di Clerico, Viola Pennisi, Alberto Vergara","doi":"10.4081/ijfs.2024.12217","DOIUrl":null,"url":null,"abstract":"Customer requests are addressed to safe products that best express their characteristics of \"naturalness\" and \"freshness\" for the entire shelf life; therefore, scientific research has been exploring the use of \"non-thermal technologies\". Thermosonication using low-frequency focused ultrasound determines bacterial inactivation through the phenomenon of \"cavitation\", guaranteeing high-quality standards of safety, nutrition, and freshness of the products. The present work aims to evaluate the effectiveness of inactivation of Salmonella typhimurium in culture broth by low-frequency focused thermosonication with two different operational parameters: sublethal temperature (40°C, 50°C) and treatment time (5, 10, and 15 minutes). Treatment determined a bacterial load reduction compared to the negative control (untreated inoculum), which was statistically significant at the T-test (p<0.05). Average decreases of 1.5 log and 3.5 CFU/mL were observed, respectively, after treatment and after 24 hours of storage at +4°C. Treatment at 50°C for 15 minutes was the most effective (average value: 3.06 log CFU/mL; minimum value: 2.13 log CFU/mL; maximum value: 4.59 log CFU/mL). However, strains have shown markable variability: one of them even showed an increase in the microbial load 24 hours after treatment at 40°C for 5 minutes (-0.20 log CFU/mL); however, the same treatment showed a reduction of bacterial charge in all the other strains (average value: 1.05 log CFU/mL; minimum value: -0.20 log CFU/mL; maximum value: 2.28 log CFU/mL). The study poses numerous perspectives on the use of low-frequency focused thermosonication treatment in the food industry as a sustainable and safe alternative to classic thermal treatments.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":"66 24","pages":""},"PeriodicalIF":17.7000,"publicationDate":"2024-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/ijfs.2024.12217","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Customer requests are addressed to safe products that best express their characteristics of "naturalness" and "freshness" for the entire shelf life; therefore, scientific research has been exploring the use of "non-thermal technologies". Thermosonication using low-frequency focused ultrasound determines bacterial inactivation through the phenomenon of "cavitation", guaranteeing high-quality standards of safety, nutrition, and freshness of the products. The present work aims to evaluate the effectiveness of inactivation of Salmonella typhimurium in culture broth by low-frequency focused thermosonication with two different operational parameters: sublethal temperature (40°C, 50°C) and treatment time (5, 10, and 15 minutes). Treatment determined a bacterial load reduction compared to the negative control (untreated inoculum), which was statistically significant at the T-test (p<0.05). Average decreases of 1.5 log and 3.5 CFU/mL were observed, respectively, after treatment and after 24 hours of storage at +4°C. Treatment at 50°C for 15 minutes was the most effective (average value: 3.06 log CFU/mL; minimum value: 2.13 log CFU/mL; maximum value: 4.59 log CFU/mL). However, strains have shown markable variability: one of them even showed an increase in the microbial load 24 hours after treatment at 40°C for 5 minutes (-0.20 log CFU/mL); however, the same treatment showed a reduction of bacterial charge in all the other strains (average value: 1.05 log CFU/mL; minimum value: -0.20 log CFU/mL; maximum value: 2.28 log CFU/mL). The study poses numerous perspectives on the use of low-frequency focused thermosonication treatment in the food industry as a sustainable and safe alternative to classic thermal treatments.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.