{"title":"Experimental verification of isolation power circuit for transformer-less AC fed electric vehicles","authors":"Tenko Fukuda,&nbsp;Tsuyoshi Funaki","doi":"10.1002/eej.23473","DOIUrl":null,"url":null,"abstract":"<p>This study aimed to develop a power supply system without a traction transformer for weight reduction and downsizing. Transformer-less power supply is expected to realize step-down, rectification, isolation, and motor drive using a high-voltage silicon carbide power device. The primary challenge of this study was developing a novel circuit that isolates the motor drive circuit from the AC line without using the traction transformer. Accordingly, we devised a flying capacitor circuit to solve the existing problems and achieve capacitive isolation. Subsequently, we devised a nesting capacitor as a short-circuit prevention measure. In this study, the operation of the isolated circuit was verified by numerical simulation, complemented by experimental verification of the proposed circuit.</p>","PeriodicalId":50550,"journal":{"name":"Electrical Engineering in Japan","volume":"217 2","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Engineering in Japan","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/eej.23473","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to develop a power supply system without a traction transformer for weight reduction and downsizing. Transformer-less power supply is expected to realize step-down, rectification, isolation, and motor drive using a high-voltage silicon carbide power device. The primary challenge of this study was developing a novel circuit that isolates the motor drive circuit from the AC line without using the traction transformer. Accordingly, we devised a flying capacitor circuit to solve the existing problems and achieve capacitive isolation. Subsequently, we devised a nesting capacitor as a short-circuit prevention measure. In this study, the operation of the isolated circuit was verified by numerical simulation, complemented by experimental verification of the proposed circuit.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
无变压器交流馈电电动汽车隔离电源电路的实验验证
本研究旨在开发一种无牵引变压器的电源系统,以减轻重量和缩小体积。无变压器电源有望利用高压碳化硅功率器件实现降压、整流、隔离和电机驱动。这项研究的主要挑战是开发一种新型电路,在不使用牵引变压器的情况下将电机驱动电路与交流线路隔离。因此,我们设计了一种飞行电容器电路来解决现有问题并实现电容隔离。随后,我们设计了一个嵌套电容器作为短路预防措施。在这项研究中,我们通过数值模拟验证了隔离电路的运行,并对所提出的电路进行了实验验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Electrical Engineering in Japan
Electrical Engineering in Japan 工程技术-工程:电子与电气
CiteScore
0.80
自引率
0.00%
发文量
51
审稿时长
4-8 weeks
期刊介绍: Electrical Engineering in Japan (EEJ) is an official journal of the Institute of Electrical Engineers of Japan (IEEJ). This authoritative journal is a translation of the Transactions of the Institute of Electrical Engineers of Japan. It publishes 16 issues a year on original research findings in Electrical Engineering with special focus on the science, technology and applications of electric power, such as power generation, transmission and conversion, electric railways (including magnetic levitation devices), motors, switching, power economics.
期刊最新文献
Issue Information Development of fatigue prediction system for bogie frame using a dynamic analysis model based on high-speed and high-precision stress estimation method Design and improvement of torque characteristics of half-wave rectified variable field flux motor with axial gap structure Evaluation of a vacuum insulated temperature calibration device to calibrate thermistor characteristics for skin cancer diagnosis Centralized control of large-scale wind farm for system frequency stabilization of the power system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1