Electrode module for EIT with a robust howland current source

IF 1.8 Q3 AUTOMATION & CONTROL SYSTEMS IFAC Journal of Systems and Control Pub Date : 2024-06-01 DOI:10.1016/j.ifacsc.2024.100265
Rafael B. Santos , André L. Santos , André C.M. Cavalheiro , Rafael A.O. Ferro , Fernando S. Moura , Raul G. Lima , Thiago C. Martins , Marcos S.G. Tsuzuki
{"title":"Electrode module for EIT with a robust howland current source","authors":"Rafael B. Santos ,&nbsp;André L. Santos ,&nbsp;André C.M. Cavalheiro ,&nbsp;Rafael A.O. Ferro ,&nbsp;Fernando S. Moura ,&nbsp;Raul G. Lima ,&nbsp;Thiago C. Martins ,&nbsp;Marcos S.G. Tsuzuki","doi":"10.1016/j.ifacsc.2024.100265","DOIUrl":null,"url":null,"abstract":"<div><p>Electrical Impedance Tomography (EIT) is a non-invasive imaging technique that reconstructs internal conductivity distributions of a body from electrical measurements taken on its boundary. This study contributes to the field by focusing on the technological intricacies of absolute EIT imaging, which is challenged by limitations such as the resolution capacity of the hardware and the complexities introduced by imaging capacitive bodies. The novel EIT system architecture proposed enhances the accuracy of measurement by integrating current sources and Analog-to-Digital Converters (ADCs) closer to the electrodes, employing alternating current excitations to accurately capture phase information. This system uses a dynamic arrangement of surface electrodes that continuously alter their roles between current injection and voltage measurement, in a synchronized sequence, to ensure the accuracy of the measurements. The paper describes the design and implementation of both the excitation and measurement subsystems, highlighting the use of digital signal demodulation near the electrode to reduce data transfer issues. Experimental results confirm the system’s capability for real-time image reconstruction at 50 frames per second with precision in phase delay measurements, suggesting significant potential for clinical and industrial applications. Future work will aim to further refine signal generation with higher-speed DACs and expand to image reconstruction with more channels.</p></div>","PeriodicalId":29926,"journal":{"name":"IFAC Journal of Systems and Control","volume":"28 ","pages":"Article 100265"},"PeriodicalIF":1.8000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IFAC Journal of Systems and Control","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468601824000269","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"AUTOMATION & CONTROL SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Electrical Impedance Tomography (EIT) is a non-invasive imaging technique that reconstructs internal conductivity distributions of a body from electrical measurements taken on its boundary. This study contributes to the field by focusing on the technological intricacies of absolute EIT imaging, which is challenged by limitations such as the resolution capacity of the hardware and the complexities introduced by imaging capacitive bodies. The novel EIT system architecture proposed enhances the accuracy of measurement by integrating current sources and Analog-to-Digital Converters (ADCs) closer to the electrodes, employing alternating current excitations to accurately capture phase information. This system uses a dynamic arrangement of surface electrodes that continuously alter their roles between current injection and voltage measurement, in a synchronized sequence, to ensure the accuracy of the measurements. The paper describes the design and implementation of both the excitation and measurement subsystems, highlighting the use of digital signal demodulation near the electrode to reduce data transfer issues. Experimental results confirm the system’s capability for real-time image reconstruction at 50 frames per second with precision in phase delay measurements, suggesting significant potential for clinical and industrial applications. Future work will aim to further refine signal generation with higher-speed DACs and expand to image reconstruction with more channels.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于 EIT 的电极模块,配有坚固耐用的 Howland 电流源
电阻抗断层成像(EIT)是一种非侵入式成像技术,可通过对人体边界的电学测量重建人体内部的电导率分布。这项研究侧重于绝对 EIT 成像技术的复杂性,为该领域做出了贡献。绝对 EIT 成像受到硬件分辨率和电容体成像复杂性等限制的挑战。所提出的新型 EIT 系统架构通过将电流源和模数转换器 (ADC) 集成到更靠近电极的位置,采用交变电流激励来准确捕捉相位信息,从而提高了测量的准确性。该系统使用表面电极的动态排列,在电流注入和电压测量之间以同步顺序不断改变其角色,以确保测量的准确性。论文介绍了激励和测量子系统的设计和实施,重点介绍了在电极附近使用数字信号解调以减少数据传输问题。实验结果证实,该系统能以每秒 50 帧的速度进行实时图像重建,并能精确测量相位延迟,这表明该系统在临床和工业应用方面具有巨大潜力。未来工作的目标是利用更高速的 DAC 进一步完善信号生成,并扩展到更多通道的图像重建。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IFAC Journal of Systems and Control
IFAC Journal of Systems and Control AUTOMATION & CONTROL SYSTEMS-
CiteScore
3.70
自引率
5.30%
发文量
17
期刊最新文献
On the turnpike to design of deep neural networks: Explicit depth bounds Finite-time event-triggered tracking control for quadcopter attitude systems with zero compensation technology Efficiency criteria and dual techniques for some nonconvex multiple cost minimization models Analysis of Hyers–Ulam stability and controllability of non-linear switched impulsive systems with delays on time scales Design of fixed-time sliding mode control using variable exponents
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1