{"title":"Redefining ITT cortisol thresholds on Abbott platforms to prevent misdiagnosis of adrenal insufficiency","authors":"Katharine Lazarus, Annabel Hayes, Kavita Narula, Debbie Papadopolou, Tricia M.-M. Tan, Karim Meeran, Sirazum Choudhury","doi":"10.1111/cen.15074","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Adrenal insufficiency (AI) is a life-threatening condition which requires long term glucocorticoid replacement. The insulin tolerance test (ITT) is the current gold standard test for diagnosis of secondary AI, but the widely accepted cut-off value of a peak cortisol of less than 500 nmol/L assumes that anyone who does not reach this value has AI and thus requires full replacement. The cut-off used to diagnose AI is also founded on outdated assays. Use of this cut-off in an era of more specific immunoassays therefore risks misdiagnosis, subsequent unnecessary glucocorticoid exposure and associated adverse effects with increased mortality risk.</p>\n </section>\n \n <section>\n \n <h3> Design, Patients and Measurements</h3>\n \n <p>This retrospective analysis assessed 300 ITT cortisol responses using the Abbott Architect and Alinity analyser platforms in patients with suspected AI over a period of 12 years (August 2010 to January 2022), at a tertiary centre.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Patients were classified as having AI or not, based on a comprehensive clinical review of electronic patient records from the point of test to the present day by a panel of pituitary and adrenal specialists. Using the current institutional cut-off value of 500 nmol/L, receiver operating characteristic analysis identified a 100.0% sensitivity and 43.6% specificity (area under the curve 0.979). Using a lower cortisol threshold value of 416 nmol/L on the Abbott analyser platform maintained a sensitivity of 100.0% and improved the specificity to 86.7%.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>This data supports lowering the Abbott analyser ITT peak cortisol threshold to 416 nmol/L. Use of this improved cut-off avoids unnecessary glucocorticoid replacement therapy in 104 (34.7%) of individuals in this study. All patients remained well with at least 1 year longitudinal follow up of glucocorticoid replacement.</p>\n </section>\n </div>","PeriodicalId":10346,"journal":{"name":"Clinical Endocrinology","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cen.15074","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Endocrinology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cen.15074","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Adrenal insufficiency (AI) is a life-threatening condition which requires long term glucocorticoid replacement. The insulin tolerance test (ITT) is the current gold standard test for diagnosis of secondary AI, but the widely accepted cut-off value of a peak cortisol of less than 500 nmol/L assumes that anyone who does not reach this value has AI and thus requires full replacement. The cut-off used to diagnose AI is also founded on outdated assays. Use of this cut-off in an era of more specific immunoassays therefore risks misdiagnosis, subsequent unnecessary glucocorticoid exposure and associated adverse effects with increased mortality risk.
Design, Patients and Measurements
This retrospective analysis assessed 300 ITT cortisol responses using the Abbott Architect and Alinity analyser platforms in patients with suspected AI over a period of 12 years (August 2010 to January 2022), at a tertiary centre.
Results
Patients were classified as having AI or not, based on a comprehensive clinical review of electronic patient records from the point of test to the present day by a panel of pituitary and adrenal specialists. Using the current institutional cut-off value of 500 nmol/L, receiver operating characteristic analysis identified a 100.0% sensitivity and 43.6% specificity (area under the curve 0.979). Using a lower cortisol threshold value of 416 nmol/L on the Abbott analyser platform maintained a sensitivity of 100.0% and improved the specificity to 86.7%.
Conclusion
This data supports lowering the Abbott analyser ITT peak cortisol threshold to 416 nmol/L. Use of this improved cut-off avoids unnecessary glucocorticoid replacement therapy in 104 (34.7%) of individuals in this study. All patients remained well with at least 1 year longitudinal follow up of glucocorticoid replacement.
期刊介绍:
Clinical Endocrinology publishes papers and reviews which focus on the clinical aspects of endocrinology, including the clinical application of molecular endocrinology. It does not publish papers relating directly to diabetes care and clinical management. It features reviews, original papers, commentaries, correspondence and Clinical Questions. Clinical Endocrinology is essential reading not only for those engaged in endocrinological research but also for those involved primarily in clinical practice.