Fluoroscopy and Radiographs for Detecting Retained Surgical Needles in the Hand.

David Woodard, Ian Ridge, Allie Blackburn, S Craig Morris, Montri Daniel Wongworawat, Jason Solomon
{"title":"Fluoroscopy and Radiographs for Detecting Retained Surgical Needles in the Hand.","authors":"David Woodard, Ian Ridge, Allie Blackburn, S Craig Morris, Montri Daniel Wongworawat, Jason Solomon","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>When a surgical needle is lost, the protocol is to explore the surgical field and to obtain a plain radiograph if the needle cannot be located. The size of the needle that can be detected with imaging is debated. Plain-film radiographs, C-arm, and mini C-arm fluoroscopy imaging was obtained of a cadaveric hand with retained needle of varying lengths (suture sizes 4-0 - 10-0). The authors performed analyses to determine the sensitivity and specificity of the imaging modalities. There were no differences in diagnostic area under the receiver operating characteristic curve between the three modalities. For plain film, optimal cutoff for needle size was 5.2 mm (sensitivity 0.87, specificity 0.75), for C-arm 6.8 mm (sensitivity 0.84, specificity 0.87), and for mini C-arm 5.9 mm (sensitivity 0.82, specificity 0.86). In the hand, the use of C-arm fluoroscopy is as sensitive as plain-film radiography at detecting retained needles greater than 5.9 mm. (Journal of Surgical Orthopaedic Advances 33(1):026-028, 2024).</p>","PeriodicalId":516534,"journal":{"name":"Journal of surgical orthopaedic advances","volume":"33 1","pages":"26-28"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of surgical orthopaedic advances","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

When a surgical needle is lost, the protocol is to explore the surgical field and to obtain a plain radiograph if the needle cannot be located. The size of the needle that can be detected with imaging is debated. Plain-film radiographs, C-arm, and mini C-arm fluoroscopy imaging was obtained of a cadaveric hand with retained needle of varying lengths (suture sizes 4-0 - 10-0). The authors performed analyses to determine the sensitivity and specificity of the imaging modalities. There were no differences in diagnostic area under the receiver operating characteristic curve between the three modalities. For plain film, optimal cutoff for needle size was 5.2 mm (sensitivity 0.87, specificity 0.75), for C-arm 6.8 mm (sensitivity 0.84, specificity 0.87), and for mini C-arm 5.9 mm (sensitivity 0.82, specificity 0.86). In the hand, the use of C-arm fluoroscopy is as sensitive as plain-film radiography at detecting retained needles greater than 5.9 mm. (Journal of Surgical Orthopaedic Advances 33(1):026-028, 2024).

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于检测手部残留手术针头的荧光透视和 X 光片。
当手术针丢失时,常规做法是对手术区域进行探查,如果无法找到针,则拍摄普通 X 光片。对于影像学检查能发现的针的大小存在争议。作者对一只有不同长度留置针(缝合线尺寸为 4-0 - 10-0)的尸体手进行了X光平片、C型臂和迷你C型臂透视成像检查。作者进行了分析,以确定成像模式的灵敏度和特异性。三种成像模式的接收者操作特征曲线下的诊断面积没有差异。对于平片,针头大小的最佳临界值为 5.2 毫米(灵敏度为 0.87,特异度为 0.75),C 型臂为 6.8 毫米(灵敏度为 0.84,特异度为 0.87),微型 C 型臂为 5.9 毫米(灵敏度为 0.82,特异度为 0.86)。在手部,使用 C 型臂透视与普通胶片 X 射线摄影在检测大于 5.9 毫米的留置针方面具有相同的灵敏度。(外科骨科进展杂志》33(1):026-028,2024 年)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Incidence of Urinary Retention Following Posterior Spinal Fusion for Adolescent and Pediatric Scoliosis at a Single Academic Center: Is There a Role for Prophylactic Tamsulosin? Indirect Coronal Reduction Technique Using a Volar Locking Plate in Distal Radius Fractures: A Case Series. Major Metropolitan Area COVID-19 - Positive Patients Undergoing Emergency and Elective Orthopaedic Surgeries: A Case-matched Control Study. Adolescent Idiopathic Scoliosis: Increased Body Mass Associated with Decreased Bracing Outcomes. Fluoroscopy and Radiographs for Detecting Retained Surgical Needles in the Hand.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1