Suture Characteristics after Exposure to Amniotic Fluid from an in vitro Model of Fetal Surgery.

IF 1.6 3区 医学 Q3 OBSTETRICS & GYNECOLOGY Fetal Diagnosis and Therapy Pub Date : 2024-01-01 Epub Date: 2024-05-31 DOI:10.1159/000539561
Cara Buskmiller, Sara Vincent, Jessian L Munoz, Magdalena Sanz Cortes, Roopali Donepudi, Divya Chilukuri, Michael A Belfort, Ahmed A Nassr
{"title":"Suture Characteristics after Exposure to Amniotic Fluid from an in vitro Model of Fetal Surgery.","authors":"Cara Buskmiller, Sara Vincent, Jessian L Munoz, Magdalena Sanz Cortes, Roopali Donepudi, Divya Chilukuri, Michael A Belfort, Ahmed A Nassr","doi":"10.1159/000539561","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Suture tensile properties have only been tested in extrauterine environments. Amniotic fluid (AF) is a complex milieu of enzymes and inflammatory factors. This study tested the mechanical properties of sutures with a variety of inherent properties, after exposure to AF from patients with conditions prompting fetal intervention.</p><p><strong>Methods: </strong>AF was obtained from 3 patients with twin-twin transfusion syndrome (TTTS), and 3 patients with neural tube defects. Six types of 2-0 sutures were placed on 1.2 N of tension to mimic placement in vivo, and incubated in AF at 37°C (98.6°F). These included ethylene terephthalate (Ethibond), glycomer 631 (V-Loc), poliglecaprone 25 (Monocryl), poly-4-hydroxybutyrate (Monomax), polydioxanone (PDS), and polyglactin 910 (Vicryl). Failure load, stress, strain, and initial modulus were tested after 24 h of incubation and after 4 weeks, and compared with control (unincubated) sutures using t tests, Kruskal-Wallis tests, and stress-strain curves.</p><p><strong>Results: </strong>Poliglecaprone 25 and polyglactin 910 dissolve more quickly in AF compared to outside the uterus, disintegrating at 4 weeks. Ethylene terephthalate and PDS experienced little change across 4 weeks of incubation. Glycomer 631 and poly-4-hydroxybutyrate exhibited interesting behavior in AF: glycomer 631 became more deformable at 24 h but later regained toughness by 4 weeks, while poly-4-hydroxybutyrate became tougher and in some cases stronger with time in AF. As a class, braided sutures act more like rigid materials, and monofilaments act like deformable plastics.</p><p><strong>Conclusion: </strong>These findings along with other suture characteristics such as ease of handling and availability may inform fetal intervention teams as they optimize procedures in a relatively new surgical field.</p>","PeriodicalId":12189,"journal":{"name":"Fetal Diagnosis and Therapy","volume":" ","pages":"463-473"},"PeriodicalIF":1.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fetal Diagnosis and Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000539561","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Suture tensile properties have only been tested in extrauterine environments. Amniotic fluid (AF) is a complex milieu of enzymes and inflammatory factors. This study tested the mechanical properties of sutures with a variety of inherent properties, after exposure to AF from patients with conditions prompting fetal intervention.

Methods: AF was obtained from 3 patients with twin-twin transfusion syndrome (TTTS), and 3 patients with neural tube defects. Six types of 2-0 sutures were placed on 1.2 N of tension to mimic placement in vivo, and incubated in AF at 37°C (98.6°F). These included ethylene terephthalate (Ethibond), glycomer 631 (V-Loc), poliglecaprone 25 (Monocryl), poly-4-hydroxybutyrate (Monomax), polydioxanone (PDS), and polyglactin 910 (Vicryl). Failure load, stress, strain, and initial modulus were tested after 24 h of incubation and after 4 weeks, and compared with control (unincubated) sutures using t tests, Kruskal-Wallis tests, and stress-strain curves.

Results: Poliglecaprone 25 and polyglactin 910 dissolve more quickly in AF compared to outside the uterus, disintegrating at 4 weeks. Ethylene terephthalate and PDS experienced little change across 4 weeks of incubation. Glycomer 631 and poly-4-hydroxybutyrate exhibited interesting behavior in AF: glycomer 631 became more deformable at 24 h but later regained toughness by 4 weeks, while poly-4-hydroxybutyrate became tougher and in some cases stronger with time in AF. As a class, braided sutures act more like rigid materials, and monofilaments act like deformable plastics.

Conclusion: These findings along with other suture characteristics such as ease of handling and availability may inform fetal intervention teams as they optimize procedures in a relatively new surgical field.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
胎儿手术体外模型暴露于羊水后的缝合特征。
引言 缝合线的拉伸性能只在宫外环境中进行过测试。羊水(AF)是一种由酶和炎症因子组成的复杂环境。本研究测试了具有各种固有特性的缝合线在暴露于羊水后的机械特性。方法 从三名双胎输血综合征(TTTS)患者和三名神经管缺陷(NTD)患者身上获取 AF。在 1.2 N 的张力下放置六种 2-0 缝合线以模拟体内放置,并在 37° C(98.6° F)的 AF 中培养。这些缝合线包括对苯二甲酸乙二醇酯(Ethibond)、glycomer 631(V-Loc)、poliglecaprone 25(Monocryl)、聚 4-羟基丁酸(Monomax)、聚二氧杂蒽酮(PDS)和聚乳酸 910(Vicryl)。在孵育 24 小时后和 4 周后测试失效载荷、应力、应变和初始模量,并使用 t 检验、Kruskal-Wallis 检验和应力-应变曲线与对照组(未孵育)缝合线进行比较。结果 Poliglecaprone 25 和 polyglactin 910 在 AF 中的溶解速度比在子宫外更快,在 4 周时崩解。对苯二甲酸乙二醇酯和聚二氧杂蒽酮在 4 周的培养过程中变化不大。甘氨醇 631 和聚 4-羟基丁酸酯在 AF 中表现出有趣的行为:甘氨醇 631 在 24 小时后变得更易变形,但随后在 4 周前恢复了韧性,而聚 4-羟基丁酸酯在 AF 中随着时间的推移变得更坚韧,在某些情况下变得更强。作为一类缝合线,编织缝合线更像刚性材料,而单丝缝合线则像可变形塑料。结论 这些发现以及其他缝合线特性(如易于处理和可用性)可为胎儿干预团队提供参考,帮助他们在这个相对较新的手术领域优化手术程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Fetal Diagnosis and Therapy
Fetal Diagnosis and Therapy 医学-妇产科学
CiteScore
4.70
自引率
9.10%
发文量
48
审稿时长
6-12 weeks
期刊介绍: The first journal to focus on the fetus as a patient, ''Fetal Diagnosis and Therapy'' provides a wide range of biomedical specialists with a single source of reports encompassing the common discipline of fetal medicine.
期刊最新文献
Risk factors for spontaneous preterm delivery in monochorionic diamniotic pregnancies undergoing selective fetal reduction via radiofrequency ablation. Fetal Megacystis - A practical guide. First trimester universal one-time serology screening for cytomegalovirus. A pilot study at two tertiary referral centers in Barcelona (Catalunya, Spain). Analysis of ultrasound findings and outcomes in fetuses with suspected congenital heart disease at less than 14 weeks' gestation compared to later gestations. Late prenatal development of hindbrain herniation in open spina bifida.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1