Comparative analysis of thrombin generation platforms for patients with coagulation factor deficiencies: A comprehensive assessment

IF 3.7 3区 医学 Q1 HEMATOLOGY Thrombosis research Pub Date : 2024-05-29 DOI:10.1016/j.thromres.2024.109045
Bauke Haisma , Saskia E.M. Schols , René G.M. van Oerle , Kitty Verbeek-Knobbe , Dave Hellenbrand , Evelien J. Verwoerd , Floor C.J.I. Heubel-Moenen , An K. Stroobants , Danielle Meijer , Sanna R. Rijpma , Yvonne M.C. Henskens
{"title":"Comparative analysis of thrombin generation platforms for patients with coagulation factor deficiencies: A comprehensive assessment","authors":"Bauke Haisma ,&nbsp;Saskia E.M. Schols ,&nbsp;René G.M. van Oerle ,&nbsp;Kitty Verbeek-Knobbe ,&nbsp;Dave Hellenbrand ,&nbsp;Evelien J. Verwoerd ,&nbsp;Floor C.J.I. Heubel-Moenen ,&nbsp;An K. Stroobants ,&nbsp;Danielle Meijer ,&nbsp;Sanna R. Rijpma ,&nbsp;Yvonne M.C. Henskens","doi":"10.1016/j.thromres.2024.109045","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Thrombin generation assays (TGAs) assess the overall functionality of the hemostatic system and thereby provide a reflection of the hemostatic capacity of patients with disorders in this system. Currently, four (semi-)automated TGA platforms are available: the Calibrated Automated Thrombogram, Nijmegen Hemostasis Assay, ST Genesia and Ceveron s100. In this study, we compared their performance for detecting patients with congenital single coagulation factor deficiencies.</p></div><div><h3>Materials and methods</h3><p>Pooled patient samples, healthy control samples and normal pooled plasma were tested on all four platforms, using the available reagents that vary in tissue factor and phospholipid concentrations. The TGA parameters selected for analysis were peak height and thrombin potential. Results were normalized by using the calculated mean of healthy controls and a correction for between-run variation. Outcomes were presented as relative values, with the mean of healthy controls standardized to 100 %.</p></div><div><h3>Results</h3><p>Across all platforms and reagents used, thrombin potentials and peak heights of samples with coagulation factor deficiencies were lower than those of healthy controls. Reagents designed for bleeding tendencies yielded the lowest values on all platforms (relative median peak height 19–32 %, relative median thrombin potential 19–45 %). Samples representing more severe coagulation factor deficiencies generally exhibited lower relative peak heights and thrombin potentials.</p></div><div><h3>Conclusions</h3><p>Thrombin generation assays prove effective in differentiating single coagulation factor deficient samples from healthy controls, with modest discrepancies observed between the platforms. Reagents designed for assessing bleeding tendencies, featuring the lowest tissue factor and phospholipid concentrations, emerged as the most suitable option for detecting coagulation factor deficiencies.</p></div>","PeriodicalId":23064,"journal":{"name":"Thrombosis research","volume":null,"pages":null},"PeriodicalIF":3.7000,"publicationDate":"2024-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0049384824001774/pdfft?md5=46b630b9e983683e2db1852d6ebc5210&pid=1-s2.0-S0049384824001774-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thrombosis research","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0049384824001774","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Thrombin generation assays (TGAs) assess the overall functionality of the hemostatic system and thereby provide a reflection of the hemostatic capacity of patients with disorders in this system. Currently, four (semi-)automated TGA platforms are available: the Calibrated Automated Thrombogram, Nijmegen Hemostasis Assay, ST Genesia and Ceveron s100. In this study, we compared their performance for detecting patients with congenital single coagulation factor deficiencies.

Materials and methods

Pooled patient samples, healthy control samples and normal pooled plasma were tested on all four platforms, using the available reagents that vary in tissue factor and phospholipid concentrations. The TGA parameters selected for analysis were peak height and thrombin potential. Results were normalized by using the calculated mean of healthy controls and a correction for between-run variation. Outcomes were presented as relative values, with the mean of healthy controls standardized to 100 %.

Results

Across all platforms and reagents used, thrombin potentials and peak heights of samples with coagulation factor deficiencies were lower than those of healthy controls. Reagents designed for bleeding tendencies yielded the lowest values on all platforms (relative median peak height 19–32 %, relative median thrombin potential 19–45 %). Samples representing more severe coagulation factor deficiencies generally exhibited lower relative peak heights and thrombin potentials.

Conclusions

Thrombin generation assays prove effective in differentiating single coagulation factor deficient samples from healthy controls, with modest discrepancies observed between the platforms. Reagents designed for assessing bleeding tendencies, featuring the lowest tissue factor and phospholipid concentrations, emerged as the most suitable option for detecting coagulation factor deficiencies.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
凝血因子缺乏症患者凝血酶生成平台的比较分析:全面评估
导言凝血酶原生成测定(TGA)可评估止血系统的整体功能,从而反映出患有止血系统疾病的患者的止血能力。目前有四种(半)自动 TGA 平台:校准自动血栓图、奈梅亨止血测定、ST Genesia 和 Ceveron s100。在本研究中,我们比较了它们在检测先天性单凝血因子缺乏症患者方面的性能。材料与方法使用组织因子和磷脂浓度不同的现有试剂,在所有四种平台上对患者样本、健康对照样本和正常集合血浆进行了检测。选择用于分析的 TGA 参数是峰高和凝血酶潜能。使用健康对照组的计算平均值对结果进行归一化处理,并对运行间的差异进行校正。结果在所有使用的平台和试剂中,凝血因子缺乏样本的凝血酶电位和峰高均低于健康对照组。在所有平台上,针对出血倾向设计的试剂产生的数值最低(峰高相对中位数为 19-32%,凝血酶潜能相对中位数为 19-45%)。结论凝血酶生成测定可有效区分单一凝血因子缺乏样本和健康对照样本,不同平台之间的差异不大。为评估出血倾向而设计的试剂具有组织因子和磷脂浓度最低的特点,是检测凝血因子缺乏症的最合适选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Thrombosis research
Thrombosis research 医学-外周血管病
CiteScore
14.60
自引率
4.00%
发文量
364
审稿时长
31 days
期刊介绍: Thrombosis Research is an international journal dedicated to the swift dissemination of new information on thrombosis, hemostasis, and vascular biology, aimed at advancing both science and clinical care. The journal publishes peer-reviewed original research, reviews, editorials, opinions, and critiques, covering both basic and clinical studies. Priority is given to research that promises novel approaches in the diagnosis, therapy, prognosis, and prevention of thrombotic and hemorrhagic diseases.
期刊最新文献
The role of anticoagulation on the long-term survival of patients with pulmonary arterial hypertension: A meta-analysis of 15 cohort studies. Hemophilia A: Economic burden, therapeutic advances, and future forecasts in the Middle East and North Africa region. Limitations of a platelet count-based clinical decision support system to facilitate diagnosis of heparin-induced thrombocytopenia Prothrombin complex concentrate for direct factor Xa inhibitor-associated bleeding or before urgent surgery. COVID-19 venous thromboembolism prophylaxis guidelines in pediatrics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1