Robot-Assisted Correction of a Supra-Long Tracheal Stenosis Using C-Type Nickel-Titanium Alloy Exterior Stenting and Suspension Fixation Technique: A Case Report.

Jingquan Han, Xi Yan, Hongwei Cui, Hang Zhang, Bei Lu, Jinzhi Xu
{"title":"Robot-Assisted Correction of a Supra-Long Tracheal Stenosis Using C-Type Nickel-Titanium Alloy Exterior Stenting and Suspension Fixation Technique: A Case Report.","authors":"Jingquan Han, Xi Yan, Hongwei Cui, Hang Zhang, Bei Lu, Jinzhi Xu","doi":"10.5761/atcs.cr.24-00012","DOIUrl":null,"url":null,"abstract":"<p><p>T-tubes and airway stents are commonly used but have limited effectiveness and frequent complications. A 50-year-old male patient presented with severe tracheal stenosis, affecting an 8.7 cm length of the airway. We employed an innovative approach known as external suspension fixation of tracheal stent using robotic assistance. This method involves surgically attaching the stent to the exterior of the trachea to provide support and stabilize the softened or collapsed tracheal segments. We designed a C-shaped nickel-titanium alloy exterior stent and successfully fixed it using robotic assistance. This intervention effectively restored tracheal function and led to a favorable postoperative recovery. The technique does not affect tracheal membrane function or airway mucociliary clearance. It could potentially be considered as a new option for treating long-segment benign tracheal softening or collapse.</p>","PeriodicalId":93877,"journal":{"name":"Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11196161/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5761/atcs.cr.24-00012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

T-tubes and airway stents are commonly used but have limited effectiveness and frequent complications. A 50-year-old male patient presented with severe tracheal stenosis, affecting an 8.7 cm length of the airway. We employed an innovative approach known as external suspension fixation of tracheal stent using robotic assistance. This method involves surgically attaching the stent to the exterior of the trachea to provide support and stabilize the softened or collapsed tracheal segments. We designed a C-shaped nickel-titanium alloy exterior stent and successfully fixed it using robotic assistance. This intervention effectively restored tracheal function and led to a favorable postoperative recovery. The technique does not affect tracheal membrane function or airway mucociliary clearance. It could potentially be considered as a new option for treating long-segment benign tracheal softening or collapse.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
机器人辅助下使用 C 型镍钛合金外支架和悬吊固定技术矫正超长气管狭窄:病例报告。
T 型管和气道支架是常用的气道支架,但效果有限且经常出现并发症。一名 50 岁的男性患者患有严重的气管狭窄,气管长度达 8.7 厘米。我们采用了一种创新方法,即利用机器人辅助进行气管支架外悬吊固定。这种方法是通过手术将支架固定在气管外部,为软化或塌陷的气管段提供支撑和稳定。我们设计了一种 C 型镍钛合金外部支架,并在机器人辅助下成功将其固定。这一干预措施有效地恢复了气管功能,术后恢复良好。该技术不影响气管膜功能和气道粘膜纤毛清除。它有可能被视为治疗长段良性气管软化或塌陷的一种新选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Lateral Dorsal Basal Lung Resection Based on Functional Preserving Sublobectomy Method: Single-Center Experience. A Novel Method of Real-Time Assessment for Coronary Artery Anastomosis Skill. Can Open Distal Repair Be Safely Used in All Patients with Type A Acute Aortic Dissection? Long-Term Outcomes of Simple Endovascular Aneurysm Repair Based on the Initial Aortic Diameter. Total Arterial Revascularization: Evaluating the Length of the Radial Artery in a Composite Graft Configuration.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1