R. D. Desiati, Eni Sugiarti, Bambang Hermanto, G. E. Timuda, H. Izzuddin, Fraya Aulia Salsabilla, A. Anawati
{"title":"Corrosion behavior of YSZ and YSZ/NiCo coatings on inconel 625 exposed alkali chlorides","authors":"R. D. Desiati, Eni Sugiarti, Bambang Hermanto, G. E. Timuda, H. Izzuddin, Fraya Aulia Salsabilla, A. Anawati","doi":"10.55713/jmmm.v34i2.1879","DOIUrl":null,"url":null,"abstract":"Alkali chloride attack on boiler pipe walls is considered the main problem of corrosion in the waste-to-energy (WTE) industry, even though uses superalloy. Electrophoretic deposited (EPD) yttria-stabilized zirconia (YSZ) coating is carried out to protect the Inconel 625 substrate. YSZ is deposited directly both on the Inconel 625 substrate and NiCo-Inconel 625. Corrosion resistance was conducted using the 3.5% NaCl electrochemical test and the hot salt corrosion test at 600°C in alkaline salt media such as NaCl, KCl, and CaCl2. The potentiodynamic polarization curve shows that the YSZ coating deposited on the substrate (single-layer) has a corrosion rate of 0.065 mm∙y‒1, lower than that deposited on NiCo coating (double-layer). The double-layer, NiO2 is formed in the NiCo layer due to the NaCl solution being trapped. Meanwhile, in hot salt corrosion at 600°C, CaCrO4 is formed as a protective oxide layer. Furthermore, in the double-layer, an imperfect oxide layer is formed causing spallation and coating failure. The corrosion rate for single-layer hot salt corrosion for 40 h is 0.310 mm∙y‒1. As a result, the corrosion resistance of the single-layer is increased by the presence of the Cr2O3 oxide layer formed during sintering.","PeriodicalId":0,"journal":{"name":"","volume":"8 4","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55713/jmmm.v34i2.1879","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Alkali chloride attack on boiler pipe walls is considered the main problem of corrosion in the waste-to-energy (WTE) industry, even though uses superalloy. Electrophoretic deposited (EPD) yttria-stabilized zirconia (YSZ) coating is carried out to protect the Inconel 625 substrate. YSZ is deposited directly both on the Inconel 625 substrate and NiCo-Inconel 625. Corrosion resistance was conducted using the 3.5% NaCl electrochemical test and the hot salt corrosion test at 600°C in alkaline salt media such as NaCl, KCl, and CaCl2. The potentiodynamic polarization curve shows that the YSZ coating deposited on the substrate (single-layer) has a corrosion rate of 0.065 mm∙y‒1, lower than that deposited on NiCo coating (double-layer). The double-layer, NiO2 is formed in the NiCo layer due to the NaCl solution being trapped. Meanwhile, in hot salt corrosion at 600°C, CaCrO4 is formed as a protective oxide layer. Furthermore, in the double-layer, an imperfect oxide layer is formed causing spallation and coating failure. The corrosion rate for single-layer hot salt corrosion for 40 h is 0.310 mm∙y‒1. As a result, the corrosion resistance of the single-layer is increased by the presence of the Cr2O3 oxide layer formed during sintering.