A nephrology trainee can define the fluid status through lung ultrasonography and inferior vena cava measurements in hemodialysis patients: an observational study in a single center.
{"title":"A nephrology trainee can define the fluid status through lung ultrasonography and inferior vena cava measurements in hemodialysis patients: an observational study in a single center.","authors":"Christodoulos Keskinis, Stylianos Panagoutsos, Eleni Soilemezi, Panagiotis Pateinakis, Parthena Kyriklidou, Evangelos Memmos, Dorothea Papadopoulou, Ploumis Passadakis","doi":"10.1007/s40477-024-00903-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>The determination of ideal weight in hemodialysis patients remains a common problem. The use of Lung Ultrasound (LUS) is an emerging method of assessing the hydric status of hemodialysis patients. LUS combined with Inferior Vena Cava (IVC) ultrasonography can define the fluid status in hemodialysis patients.</p><p><strong>Methods: </strong>This study included 68 hemodialysis patients from the Dialysis Unit of Papageorgiou General Hospital in Thessaloniki. The patients underwent lung and IVC ultrasound 30 min before and after the end of the dialysis session by a nephrology trainee. Patients' ideal weight was modified based on daily clinical practice rather than ultrasound findings. The presence of B lines and ultrasound findings of the IVC were evaluated.</p><p><strong>Results: </strong>The average B line score was 11.53 ± 5.02 before dialysis and became 5.57 ± 3.14 after the session. The average diameter of the IVC was 14.266 ± 0.846 mm before dialysis and 12.328 ± 0.879 mm after the session. The patients were categorized based on the magnitude of overhydration and the findings were evaluated. In addition, findings after the session showed a statistically significant correlation between the b line score and the diameter of the IVC adjusted for the body surface area. (p = 0.009 < 0.05).</p><p><strong>Conclusions: </strong>A high rate of hyperhydration was detected before the dialysis session (25%). While it is the first study conducted by a nephrology trainee highlighting that it is a feasible technique. Intervention studies should be carried out in the future to draw more precise conclusions.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":" ","pages":"887-894"},"PeriodicalIF":1.3000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11496488/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-024-00903-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Aims: The determination of ideal weight in hemodialysis patients remains a common problem. The use of Lung Ultrasound (LUS) is an emerging method of assessing the hydric status of hemodialysis patients. LUS combined with Inferior Vena Cava (IVC) ultrasonography can define the fluid status in hemodialysis patients.
Methods: This study included 68 hemodialysis patients from the Dialysis Unit of Papageorgiou General Hospital in Thessaloniki. The patients underwent lung and IVC ultrasound 30 min before and after the end of the dialysis session by a nephrology trainee. Patients' ideal weight was modified based on daily clinical practice rather than ultrasound findings. The presence of B lines and ultrasound findings of the IVC were evaluated.
Results: The average B line score was 11.53 ± 5.02 before dialysis and became 5.57 ± 3.14 after the session. The average diameter of the IVC was 14.266 ± 0.846 mm before dialysis and 12.328 ± 0.879 mm after the session. The patients were categorized based on the magnitude of overhydration and the findings were evaluated. In addition, findings after the session showed a statistically significant correlation between the b line score and the diameter of the IVC adjusted for the body surface area. (p = 0.009 < 0.05).
Conclusions: A high rate of hyperhydration was detected before the dialysis session (25%). While it is the first study conducted by a nephrology trainee highlighting that it is a feasible technique. Intervention studies should be carried out in the future to draw more precise conclusions.
期刊介绍:
The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.